background image

 
Before You Begin

 

-2- 

 

Vesuvio™ RGBA User Manual Rev. 1 

Safety Notes 

Read all the following Safety Notes before working with this product. These notes include 
important information about the installation, usage, and maintenance of this product. 

 

This product contains no user-serviceable parts. Any reference to servicing in this User 
Manual will only apply to properly trained CHAUVET® certified technicians. Do not open 
the housing or attempt any repairs. 

 

All applicable local codes and regulations apply to proper installation of this product. 

Personal Safety 

 

Avoid direct eye exposure to the light source while the product is on. 

 

Always disconnect this product from its power source before servicing. 

 

Always connect this product to a grounded circuit to avoid the risk of electrocution. 

 

he product’s nozzle is very hot during operation and it remains hot for a long time after 
operation has stopped. 

 

The fog exits the nozzle at a very high temperature. Keep a minimum distance of  
6.5 ft (2 m) from the nozzle to the nearest object. 

 

Do not use the product as a space heater. 

 

Do not drink or become in contact with the fog fluid. If you do, call your local emergency 
service (911 in the US) for help. 

 

Do not add perfume, alcohol, gasoline, or any other flammables to the fog fluid.Do not 
touch this product’s housing during operation because it may be very hot. 

Mounting And 

Rigging 

 

The product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose 
the product to rain or moisture. 

 

Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from 
adjacent surfaces.  

 

Make sure there are no flammable materials close to this product while it is operating. 

 

When hanging this product, always secure to a fastening device using a safety cable. 

Power And 

Wiring 

 

Always make sure you are connecting this product to the proper voltage in accordance 
with the specifications in this manual or on the product’s specification label. 

 

Never connect this product to a dimmer pack or rheostat. 

 

Make sure the power cord is not crimped or damaged. 

 

Never disconnect this product by pulling or tugging on the power cable. 

Operation 

 

Make sure there is adequate fog fluid in the machine to prevent pump and heater damage. 

 

Never carry the product by the power cord or any moving part. Always use the handles. 

 

Do not operate this product if you see damage on the housing, lenses, or cables. Have the 
damaged parts replaced by an authorized technician at once. 

 

You may hear a loud popping sound during operation. This is normal. 

 

Do not cover the ventilation slots when operating to avoid internal overheating. 

 

The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at a 
higher temperature. 

 

Never try to repair the product. Repairs carried out by unskilled people can lead to damage 
or malfunction. Contact the nearest authorized technical assistance center. 

 

This product is not intended for permanent installation. 

 

Use only CHAUVET® water-based fog fluid. 

 

Drain the tank before transporting the product. 

 

In case of a serious operating problem, stop using this product immediately! 

 

In the unlikely event that your CHAUVET® product may require service, contact 
CHAUVET® Technical Support. 

Expected LED 

Lifespan 

LEDs gradually decline in brightness over time, mostly because of heat. Packaged in clusters, 
LEDs exhibit higher operating temperatures  than in ideal, single-LED  conditions. For this 
reason, using clustered LEDs at their fullest intensity significantly reduces the LEDs’ lifespan. 
Under normal conditions, this lifespan can be 40,000 to 50,000 hours. If extending this lifespan 
is vital, lower the operating  temperature by improving the  ventilation  around the product and 
reducing the ambient temperature to an optimal operating range. In addition, limiting the overall 
projection intensity may also help to extend the LEDs’ lifespan. 

 

Summary of Contents for Green Thinking Professional Vesuvio RGBA

Page 1: ...User Manual ...

Page 2: ...only CHAUVET expressly prohibits the usage copy storage distribution modification or printing of this manual or its content for any other purpose without written consent from CHAUVET Document Printing For better results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure your printer to scale the content accordingly Intended Audience ...

Page 3: ...ntions 1 Symbols 1 Safety Notes 2 Personal Safety 2 Mounting And Rigging 2 Power And Wiring 2 Operation 2 Expected LED Lifespan 2 2 Introduction 3 Description 3 Features 3 Overview 4 Dimensions 5 3 Setup 6 AC Power 6 AC Plug 6 Resetting the Breaker 6 DMX Linking 6 DMX Personalities 6 Mounting 7 Orientation 7 Rigging 7 Procedure 7 ...

Page 4: ...ontrol Options 8 Programming 8 Preparing for Operation 8 Startup 8 Menu Map 9 DMX Values 9 Starting Address 10 Setting the LED Color 10 Timer Mode 10 Manual Mode 10 Timer Mode Parameters 10 5 Technical Information 11 Maintenance 11 Storage 11 6 Technical Specifications 12 Returns 13 Contact Us 13 ...

Page 5: ...T within 7 days of delivery Manual Conventions Convention Meaning 1 512 A range of values in the text 50 60 A set of mutually exclusive values in the text SET A button on the product s control panel Settings A product function or a menu option MENU Settings A sequence of menu options 1 10 A range of menu values from which to choose in a menu Yes No A set of two mutually exclusive menu options in a...

Page 6: ...s product to the proper voltage in accordance with the specifications in this manual or on the product s specification label Never connect this product to a dimmer pack or rheostat Make sure the power cord is not crimped or damaged Never disconnect this product by pulling or tugging on the power cable Operation Make sure there is adequate fog fluid in the machine to prevent pump and heater damage ...

Page 7: ...eating 1 6 kW heater a 2 5 liter fluid tank and features a 40 000 cubic feet per minute cfm output Features Advanced red green blue and amber RGBA LED color mixing 40 000 cfm fog output for intense large effects 2 5 l fluid tank for reliability in production 1 6 kW fluid heater for voluminous heavy bursts of fog Strong sturdy construction for numerous production types DMX control for ease of use i...

Page 8: ...4 Vesuvio RGBA User Manual Rev 1 Overview Power In DMX Out Control Panel Front View Rear View Side View Handle Safety Loop LED s Nozzle Fluid Tank Fluid Tank Hose DMX In DMX Out Power Switch Breaker DMX Out Top View ...

Page 9: ...Introduction Vesuvio RGBA User Manual Rev 1 5 Dimensions 13 23 in 336 mm 9 09 in 231 mm 19 21 in 488 mm ...

Page 10: ...er input circuit If the breaker trips all sections of this product will lose power Refer to the following instructions for resetting the breaker This product is equipped with a resettable circuit breaker If the breaker trips all sections of this product will lose power 1 Disconnect the product from power 2 Allow the product to cool for 15 minutes 3 After 15 minutes try to reset the breaker by pres...

Page 11: ... an installation location consider easy access to this product for operation programming adjustments and routine maintenance Make sure to mount this product away from any flammable material as indicated in the Safety Notes Never mount in places where rain high humidity extreme temperature changes or restricted ventilation may affect the product Procedure The Vesuvio RGBA comes with rubber feet for...

Page 12: ...teps 1 Withdraw the fluid tank from its compartment and remove its cap 2 Verify that the two plastic hoses attached to the cap are in place and in good condition 3 Pour CHAUVET HDF or QDF fog fluid into the tank and replace the cap 4 Return the tank back to its compartment in the Vesuvio RGBA 5 Make sure the plastic hose entering the Vesuvio RGBA from the fluid tank cap is not bent or kinked 6 Con...

Page 13: ...nterval Set CHAUVET 1 200s Duration Set CHAUVET 1 10s Color CHAUVET 1 7 DMX512 Add CHAUVET 1 512 DMX Values 9CH Channel Function Value Percent Setting 1 Fog 000ó010 011ó255 No function Fog on 2 Dimmer 000ó255 0 100 3 Red 000ó255 0 100 4 Green 000ó255 0 100 5 Blue 000ó255 0 100 6 Amber 000ó255 0 100 7 Strobe 000ó255 0 100 8 Auto Color 000ó010 011ó255 No function Color mixing 9 Auto Speed 000ó255 0 ...

Page 14: ... 1 Press TIMER and the display will show a countdown of the interval timer 2 When the counter reaches zero 0 the Vesuvio RGBA will start producing haze and light 3 The haze and light output duration during Timer mode is set by the Duration Set menu option 4 The color of the LEDs is set using the Color menu option 5 This cycle will repeat itself until you press TIMER again or until the Vesuvio RGBA...

Page 15: ...e a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents 8 Clean all external surfaces with a mild solution of non ammonia glass cleaner or isopropyl alcohol 9 Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue 10 Wipe any dirt or grime to the outside edges of the lens surface 11 Gently polish the lens surfaces until they ...

Page 16: ... Power input connector Neutrik powerCON A Neutrik powerCON A Power cord plug Edison U S Local plug Light Source Type Power Lifespan LED 2 W 50 000 hours Color Quantity Current Red 7 650 mA Green 7 650 mA Blue 7 650 mA Amber 7 650 mA Photo Optic Parameter Standard Optics Illuminance 5 m 720 lux Operation Capacity Consumption Heat up Time Tank Capacity Fluid Consumption 7 min 0 7 gal 2 5 l 150 ml mi...

Page 17: ...dEx packing or double boxing is recommended CHAUVET reserves the right to use its own discretion to repair or replace returned product s CONTACT US WORLD HEADQUARTERS CHAUVET General Information Address 5200 NW 108 th Avenue Sunrise FL 33351 Voice 954 577 4455 Fax 954 929 5560 Toll free 800 762 1084 Technical Support Voice 954 577 4455 Press 4 Fax 954 756 8015 Email tech chauvetlighting com World ...

Reviews: