Chauvet Gobo Zoom LED 2.0 User Manual Download Page 10

Page 10 of 15 

Gobo Zoom LED 2.0  (Rev. 02) 

 

DMX Primer 

 

 

 

There are 512 channels in a DMX connection. A product capable of receiving DMX will 

require one or a number of sequential channels. The user must assign a starting 

address on the product that indicates the first channel reserved in the controller. There 
are many different types of DMX controllable products and they all may vary in the 

total number of channels required. Choosing a start address should be planned in 

advance. Channels should never overlap. If they do, this will result in erratic operation 
of the products whose starting address is set incorrectly. You can however, control 

multiple products of the same type using the same starting address as long as the 

intended result is that of unison movement or operation. In other words, the products 
will all respond exactly the same.  

 

DMX products are designed to receive data through a daisy chain. A daisy chain 
connection is where the DATA OUT of one product connects to the DATA IN of the 

next product. The order in which the products are connected is not important and has 

no effect on how a controller communicates to each product. Use an order that 
provides for the easiest and most direct cabling. Connect products using shielded two 

conductor twisted pair DMX data cable with three pin XLR male to female connectors. 

The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data 
positive (S+).

 

 

 

Product Linking (Daisy Chain) 

 

 

 

You will need a daisy chain to run light shows of one or more products using a DMX 
controller or to run synchronized shows on two or more products set to a master/slave 

operating mode. The combined number of channels required by all the products on a 

daisy chain determines the number of products the data link can support.  

 

 

 

To comply with the EIA-485 standard, do not connect more than 32 products on 

one daisy chain. Connecting more than 32 products on one daisy chain without 

the use of a DMX optically-isolated splitter may result in deterioration of the 

digital DMX signal.  

 

Maximum recommended cable distance: 500 m (1640 ft)  
Maximum recommended number of products on a daisy chain: 32 

 

 

Data Cabling 

 

 

 

To link products together you must obtain data cables. You can purchase CHAUVET® 

certified DMX cables directly from a dealer/distributor or construct your own cable. If 

you choose to create your own cable please use data-grade cables that can carry a 
high quality signal and are less prone to electromagnetic interference.

 

 

 

DMX Data Cable 

 

 

 

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-

485 applications. Standard microphone cables cannot transmit DMX data reliably over 

long distances. The cable must have the following characteristics: 

 

Type: 

shielded, 2-conductor twisted pair 

Maximum capacitance between conductors: 

30 pF/ft 

Maximum capacitance between conductor and shield: 

55 pF/ft 

Maximum resistance: 

20 ohms/1000 ft 

Nominal impedance: 

100 ~ 140 ohms 

 

 

Summary of Contents for Gobo Zoom LED 2.0

Page 1: ...User Manual...

Page 2: ...MOUNTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 CONFIGURING THE STARTING ADDRESS 8 DMX Operation 8 Standalone 8 DMX CHANNEL VALUES 8 5 APPENDIX 9 GENERAL TROUBLESHOOTING 9 DMX PRIMER 10...

Page 3: ...n seven 7 days of receiving the merchandise Manual Conventions CHAUVET manuals use the following conventions to differentiate certain types of information from the regular text CONVENTION MEANING 10 A...

Page 4: ...t from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure product to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C...

Page 5: ...e 5 of 15 2 INTRODUCTION Product Overview Power In DMX Out Bracket Adjustment Knob Safety Bracket Adjustment Knob Mounting Bracket DIP Switches DMX In Fuseholder Zoom Thumbscrew Adjustment Focus Thumb...

Page 6: ...rcuit with a suitable electrical ground Replacing the Gobo Color Gel This product has replaceable gobos and colored gels See the instructions below 1 Remove power to the Gobo Zoom LED 2 0 2 On the und...

Page 7: ...ct securely This may be done with a screw nut and bolt or a hanging clamp The hole in each bracket is 13 mm in size When rigging consider routine maintenance and control panel access Please see the fo...

Page 8: ...ecommended that you refer to the DMX Primer section in the Appendix of this manual Mode DIP switches DMX 1 9 set to the DMX starting address 10 On DMX mode Standalone This product has preprogrammed op...

Page 9: ...sing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replac...

Page 10: ...ile pin 2 is Data Negative S and pin 3 is Data positive S Product Linking Daisy Chain You will need a daisy chain to run light shows of one or more products using a DMX controller or to run synchroniz...

Page 11: ...to read the data on the channel indicated by the start address For example a product that uses six DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102...

Page 12: ...Pin 4 Not used Pin 5 Setting up a DMX Daisy Chain 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming...

Page 13: ...hich the product operates Damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Clean the ex...

Page 14: ...mm Image 26 mm Maximum thickness 1 mm LIGHT SOURCE Type high power single source LED Quantity 1 Rating white 15 W 4 A 50 000 hrs PHOTO OPTIC Zoom angle 18 25 INDOOR OUTDOOR Rating For indoor use only...

Page 15: ...rmation CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108th Ave Sunrise FL 33351 voice 954 929 1115 Press 4 f...