Operating Modes 

The Omega I can be operated in three ways.  

 

 

A stand-alone mode will listen to sound and run through its diverse range of built in programs. A CH-x 
wired controller provides remote blackout control. 

 

Master/Slave mode will allow the command of up to as many units you want in a synchronized light 
show to the sound. 

 

DMX control mode will provide the greatest flexibility and creativity. Each fixture trait can be controlled 
individually using any universal DMX-512 controller.  

Stand Alone 

The Stand Alone mode is activated automatically when the fixture is absent of DMX signal or a 

controller is not connected. The Omega I will run through it’s built in programs as it listens to the 

sound. The optional CH-X wired controller provides a blackout function. 

Master/Slave 

The Master/Slave mode will allow you to link up to as many units you want in a daisy chain fashion. In 

this mode, the first unit in the daisy chain will automatically command all other units following. A CH-X 

controller connected to the first unit in the chain will allow a blackout function. Connecting the Omega 

I for (Master/Slave) operation does not require any menu or setting selections. Simply connect each 

Omega I in a daisy like fashion using qualified 3 pin DMX cables as described below.   

M A S T E R / S L A V E   S E T T I N G S  

1) 

Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector 
of the first fixture.  

2) 

Connect the end of the cable coming from the first fixture which will have a (female) 3 pin 
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, 
proceed to connect from the output as stated above to the input of the following fixture and so on 
as illustrated below. 

Note!  

For additional information on linking fixtures read under section “DMX Primer” 

DMX Mode 

S E T T I N G   T H E   S T A R T I N G   A D D R E S S  

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start 

address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data 

on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels 

of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 

102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate 

the start address selected for future reference.  

Summary of Contents for DMX-155 Omega I

Page 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com DMX 155 Omega I USER MANUAL ...

Page 2: ...tallation 6 POWER 6 MOUNTING 7 Orientation 7 Rigging 7 MANUAL FOCUSING 7 FUSE REPLACEMENT 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 DMX Mode 8 Setting the starting address 8 Pan Tilt Invert 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 ABOUT STROBE GOBO STROBE 11 MAINTENANCE 12 RETURNS PROCEDURE 12 CLAIMS 12 GENERAL TRO...

Page 3: ...Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or sho...

Page 4: ...icro stepping motors built in beat activated programs built in microphone automatically enters stand alone mode when no DMX signal is present fan cooled linkable via master slave controller programmable via any universal DMX controller thermal switch switch selectable power setting 115V 230V 2 year warranty DMX Channel Summary CHANNEL FUNCTION 1 Color Gobo 2 Strobe 3 Pan 4 Tilt ...

Page 5: ...blackout controller Safety Hook Attach safety cable to this hook Audio Sensitivity POT Adjust audio sensitivity to improve fixture response Integrated Mic Dipswitches Provided for DMX channel addressing Voltage Selector Choose either 115V or 230V operation Power Input Fuse Holder Manual Focus Lens Gun Hanging Bracket Yoke Yoke tensioning knob Lamp cover Top plate Fan Bottom of fixture ...

Page 6: ...e lamp socket and follow the same procedure as above to insert lamp into lamp cage 5 Replace top cover and screws 6 No lamp alignment is necessary for this fixture Power Your product is equipped with switch selectable AC power setting Warning Verify that the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground To ...

Page 7: ...fety cables should always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Manual Focusing To adjust the focus please follow the instructions below 1 If operating in stand alone mode turn the music down so that the unit temporarily stops any activity 2 In DMX control mode create a static scene with any gobo ...

Page 8: ...chain will allow a blackout function Connecting the Omega I for Master Slave operation does not require any menu or setting selections Simply connect each Omega I in a daisy like fashion using qualified 3 pin DMX cables as described below MASTER SLAVE SETTINGS 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the...

Page 9: ...the selected start address which does not cause a negative number Pan Tilt Invert This feature allows the user to reverse the Pan and Tilt movement on each fixture regardless of the operating mode Only the mirror movement would be affected by this setting You will notice that the fixture s mirror home setting upon initializing would be set completely opposite of the others not set to Invert Set di...

Page 10: ...f one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whil...

Page 11: ... activated mode 2 000 Ù 009 010 Ù 045 046 Ù 115 116 Ù 150 151 Ù 185 186 Ù 220 221 Ù 255 Strobe Gobo Strobe Open Strobe Speed 1 Strobe Speed 2 Strobe Speed 3 Strobe Speed 4 Strobe Speed 5 Strobe Speed 6 3 000 Ù 255 Pan Left Right 128 Center 4 000 Ù 255 Tilt Down Up 128 Center About Strobe Gobo Strobe The Omega I shares the strobe function on the color gobo combo wheel To achieve a flash type strobe...

Page 12: ...n the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid...

Page 13: ...io provided via jack make sure a live audio signal exists Adjust sound sensitivity knob 9 9 9 Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up 9 Loss...

Page 14: ...C input 3 prong IEC 60320 C14 LAMPS EFR5 500 hrs 150W 15V THERMAL Maximum ambient temperature 40 104 F FUSE Main 115V 20mm Glass 3 15A Fast Blow Main 230V 20mm Glass 1 6A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 4 ORDERING INFORMATION Omega I DMX 15...

Reviews: