Master/Slave & Stand Alone 

The Master/Slave mode will allow you to link units in a daisy chain fashion. In this mode, the first unit 

in the daisy chain will command all other units following. Stand Alone can simply be achieved by 

setting all units to Master. They would no longer be required to be linked in series.   

Built in programs detailed 

P

ROGRAM

  F

UNCTION

 

O

PTIONS

 

000 

Blackout 

 

001-007 

Solid flashing colors 

= Flash speed 

008-013 

Color chase programs 

= Run speed 

F = Flash speed 

014-020 

Sequential color chase patterns 

Use sound sensitivity rotary knob to adjust sound 

level for optimum response or decrease sensitivity 

completely to operate in Run speed only 

= Run speed 

021 

RGB (manual color mix) 

= Red 

= Green 

= Blue 

022 

Color fade 

= Run speed 

023 

Auto run (sound active only) 

 

MASTER UNIT Settings 

1. 

Press the Mode button 
repeatedly until the display 
reads [Act] then press the 
Enter button. 

2. 

Select programs 001 ~ 023 
by using the Up and Down 
buttons. 

3. 

Some programs have 
additional controls such as 
flash and run speed. Press 
the Mode button once again 
to toggle additional 
functions, then use the Up 
and Down buttons to 
change values. 
 
Refer to the Control Panel 
Modes & Functions chart on 
the previous page.
 

3 Pin XLR DMX cable 

SLAVE UNIT Settings 

1. 

Units that follow the Master 
unit will automatically 
synchronize to the Master 
unit. No other settings are 
required. 

Master 

Slave 

Slave 

Slave 

Master/Slave Link output 

IMPORTANT INSTRUCTIONS FOR MASTER/SLAVE OPERATION 

Turn ON the Master unit last! This will assure that the master unit will detect fully all linked units and re-

configure its

 built in sequential chase programs to run on the correct number of linked units. 

DMX signal 
output does not 
continue on M/S 
linked fixtures. 

Summary of Contents for COLORbank 4

Page 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 04 18 16 44 LED BANK4 COLORbank 4 USER MANUAL ...

Page 2: ...R 6 MOUNTING 6 OPERATING INSTRUCTIONS 7 USING THE CONTROL PANEL 7 Control Panel Modes Functions 7 MASTER SLAVE STAND ALONE 8 Built in programs detailed 8 DMX CONTROL MODE 9 Daisy Chain Connection 9 DMX mode setup 9 About DMX addressing 10 CONTROLLING MULTIPLE COLORBANKS AS ONE DEVICE 10 APPENDIX 11 DMX PRIMER 11 Fixture Linking 11 DMX CHANNEL VALUES 12 RETURNS PROCEDURE 13 CLAIMS 13 TECHNICAL SPEC...

Page 3: ...u are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with a...

Page 4: ...n page 12 in the Appendix section Blackout and Static Flashing colors INTRODUCTION Features 4 channel DMX 512 LED bank system Operating modes o Blackout and static flashing colors o RGB color mixing o Color fade o Automatic built in programs with sound activation 304 LEDs divided into 4 surfaces 76 LEDs per surface o 40 red 18 green 18 blue diodes per bank RGB color mixing Built in color change pr...

Page 5: ...urface area IEC power input connector power link output COLORbank data link DMX input output connectors Microphone sensitivity dial Control panel Built in microphone Mode Enter Up Down LED display Mode Indicator Number display Striplight linear attachment accessory 1 2 Product Overview ...

Page 6: ...heostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE EU CABLE US PIN INTERNATIONAL BROWN Black Live L BLUE White Neutral N YELLOW ...

Page 7: ...rtain to that function 3 Press ENTER to enter the sub menus Control Panel Modes Functions MODE FUNC PROGRAM FUNCTION PROGRAM P RUN SPEED F FLASH SPEED C COLOR 001 Blackout Yes 002 Red Yes 003 Green Yes 004 Blue Yes 005 Yellow Yes 006 Purple Cyan Yes 007 White Yes 008 Color Change 1 Yes Yes 009 Color Change 2 Yes Yes 010 Color Change 3 Yes Yes 011 Color Change 4 Yes Yes 012 Color Change 5 Yes 013 C...

Page 8: ...ade P Run speed 023 Auto run sound active only MASTER UNIT Settings 1 Press the Mode button repeatedly until the display reads Act then press the Enter button 2 Select programs 001 023 by using the Up and Down buttons 3 Some programs have additional controls such as flash and run speed Press the Mode button once again to toggle additional functions then use the Up and Down buttons to change values...

Page 9: ... male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on DMX mode setup 3 Press the Mode button until the dispplay reads SyS then press Enter 4 Press the Up and Down buttons until the display reads S dAd then press Enter 5 Set the DMX address value by using the Up and Down buttons 6 Press the Mode button use the Up Down until the...

Page 10: ...on that will help you understand its use Controlling multiple COLORbanks as one device 1 Turn on all fixtures 2 On the first fixture press the Mode button until the dispplay reads SyS then press Enter 3 Press the Up and Down buttons until the display reads S dAd then press Enter 4 Set the DMX address value by using the Up and Down buttons 5 Press the Mode button use the Up Down until the display r...

Page 11: ...of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whi...

Page 12: ... 4 000 009 010 019 020 029 030 039 040 049 050 059 060 069 070 079 Static Colors Blackout Red Green Blue Yellow Purple Cyan White Flash Speed 000 249 Sound Active 250 255 080 089 090 099 100 109 110 119 Color Changes Color change 1 Color change 2 Color change 3 Color change 4 Flash Speed 000 249 Sound Active 250 255 120 129 130 139 Color change 5 Color change 6 140 149 150 159 160 169 170 179 180 ...

Page 13: ... damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It ...

Page 14: ... pin XLR female socket 2nd female XLR for linking purposes only Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 4 FUSE Main 20mm Glass 2A 250W Fast Blow LEDS Quantity of LEDs 304 Total divided into 4 surface areas Red 40 Green 36 Blue 36 in each area ORDERING INFORMATION COLORbank 4 LED BANK4 FUSE 2A 250W P170FUSE002 Technical Support Address Service Dept 3000 ...

Reviews: