General Maintenance 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should 

be cleaned at least twice a month. Dust build up reduces light output performance and can cause 

overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off 

fixture before conducting maintenance. 

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust 

collected on external vents and internal components.  Clean all glass when the fixture is cold with a 

mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply 

solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical 

surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil 

and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or 

becomes dirty, clean the lamps with an alcohol wipe.  

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 

damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s 

optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean 

the external optics at least every 20 days. Clean the internal optics at least every 30/60 days. 

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products 

returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause 

for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate 

packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to 

repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe 

method to use. 

Claims 

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 

reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and 

submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any other claim 

for items such as missing component/part, damage not related to shipping, and concealed damage, 

must be made within seven (7) days of receiving merchandise.  

Summary of Contents for CH-330 Triple Derby

Page 1: ...Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 08 25 20 37 CH 330 Triple Derby USER MANUAL ...

Page 2: ...AFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 MOUNTING 5 Orientation 5 Rigging 5 OPERATING INSTRUCTIONS 6 Duty Cycle 6 APPENDIX 7 GENERAL MAINTENANCE 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 8 LAMP IN SERIES WIRING FOR 230V OPERATION 9 TECHNICAL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 ...

Page 3: ...his User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not exp...

Page 4: ...INTRODUCTION Features Sound activated 24 lenses 48 beams Sound Sensitivity knob Built in microphone Safety hook Fan cooled Product Overview Hanging bracket Sound sensitivity knob Lamp access Voltage select switch Fuse Microphone Safety hook ...

Page 5: ... in the image 2 Flip open to expose lamp and socket 3 If replacing the lamp remove old lamp first 4 Using a cloth or napkin hold the bulb and pull out of the lamp socket located inside the reflector 5 Replace with a new lamp 6 Flip cover to close align the screw hole and fasten the screw Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilatio...

Page 6: ...le effect light from a switch panel Make sure to use a cable of at least 25 feet to provide ample distance between the control panel and the switch pack for most mobile lighting applications If you would prefer to control it directly from your DMX lighting console then we suggest a DMX compatible relay switch pack These devices are an extremely affordable solution to operating non DMX lighting eff...

Page 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Page 8: ... in order to measure correctly check to see if perhaps it is stuck 9 Fogger or Snow output has dropped Clean with distilled water and vinegar Replace hose 9 Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kic...

Page 9: ...eir 230V counter parts Technical Specifications WEIGHT DIMENSIONS Length 431 mm 17 in Width 406 mm 16 in Height 178 mm 7 in Weight 10 4 Kgs 23 lbs POWER Switch selectable power 115V 60Hz or 230V 50Hz DUTY CYCLE RECOMMENDED 1 Fixture ON not to exceed 15 minutes 2 Fixture OFF cool down for 15 minutes LAMPS 64514 300W 120V 230V 64514 x 2 In Series 300W 120V THERMAL Maximum ambient temperature 40 104 ...

Reviews: