background image

 

CH-330 User Manual 

2006-08-25/20:37 

S1

Lamp cover 

plate 

Hanging Clamp 

S

ETUP

 

Lamp 

You may need to install a lamp prior to the initial operation of the fixture. Two 64514 300W halogen 

bi-pin lamps are included.  

Warning!  When replacing the lamp, please wait 15 minutes after powering down to allow the unit to 

cool down! Always disconnect from main power prior to lamp replacement.  

Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp 

with alcohol and wipe it with a lint free cloth before installation. 

For lamp installation in 230V environments please read “Lamp (In-Series) Wiring” in the 

Appendix section of this manual. 

L A M P   I N S T A L L A T I O N  

1) 

Remove the (S1) screw located on top of the 
fixture as shown in the image.  

2) 

Flip open to expose lamp and socket. 

3) 

If replacing the lamp, remove old lamp first. 

4) 

Using a cloth or napkin hold the bulb and 
pull out of the lamp socket located inside the 
reflector. 

5) 

Replace with a new lamp. 

6) 

Flip cover to close, align the screw hole and 
fasten the screw. 

Mounting 

O R I E N T A T I O N  

This fixture may be mounted in any position provided there is adequate room for ventilation.  

R I G G I N G    

It is important never to obstruct the fan or vents pathway. Mount the fixture using, a suitable “C” or “O” 

type clamp. Adjust the angle of the fixture by loosening both knobs and tilting the fixture. After finding 

the desired position, retighten both knobs. 

 

When selecting installation location, take into consideration lamp 
replacement access and routine maintenance.  

 

Safety cables should always be used.  

 

Never mount in places where the fixture will be exposed to rain, high 
humidity, extreme temperature changes or restricted ventilation. 

Summary of Contents for CH-330 Triple Derby

Page 1: ...Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 08 25 20 37 CH 330 Triple Derby USER MANUAL ...

Page 2: ...AFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 MOUNTING 5 Orientation 5 Rigging 5 OPERATING INSTRUCTIONS 6 Duty Cycle 6 APPENDIX 7 GENERAL MAINTENANCE 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 8 LAMP IN SERIES WIRING FOR 230V OPERATION 9 TECHNICAL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 ...

Page 3: ...his User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not exp...

Page 4: ...INTRODUCTION Features Sound activated 24 lenses 48 beams Sound Sensitivity knob Built in microphone Safety hook Fan cooled Product Overview Hanging bracket Sound sensitivity knob Lamp access Voltage select switch Fuse Microphone Safety hook ...

Page 5: ... in the image 2 Flip open to expose lamp and socket 3 If replacing the lamp remove old lamp first 4 Using a cloth or napkin hold the bulb and pull out of the lamp socket located inside the reflector 5 Replace with a new lamp 6 Flip cover to close align the screw hole and fasten the screw Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilatio...

Page 6: ...le effect light from a switch panel Make sure to use a cable of at least 25 feet to provide ample distance between the control panel and the switch pack for most mobile lighting applications If you would prefer to control it directly from your DMX lighting console then we suggest a DMX compatible relay switch pack These devices are an extremely affordable solution to operating non DMX lighting eff...

Page 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Page 8: ... in order to measure correctly check to see if perhaps it is stuck 9 Fogger or Snow output has dropped Clean with distilled water and vinegar Replace hose 9 Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kic...

Page 9: ...eir 230V counter parts Technical Specifications WEIGHT DIMENSIONS Length 431 mm 17 in Width 406 mm 16 in Height 178 mm 7 in Weight 10 4 Kgs 23 lbs POWER Switch selectable power 115V 60Hz or 230V 50Hz DUTY CYCLE RECOMMENDED 1 Fixture ON not to exceed 15 minutes 2 Fixture OFF cool down for 15 minutes LAMPS 64514 300W 120V 230V 64514 x 2 In Series 300W 120V THERMAL Maximum ambient temperature 40 104 ...

Reviews: