DMX Address Quick Reference Chart 

Dip Switch Position 

DMX DIP SWITCH SET  #9 

0=OFF 

#8 

1=ON 

#7 

X=OFF or ON 

#6 

0 

#1  #2  #3  #4  #5 

 

 

 

32  64 

96 

128 

160 

192 

224 

256 

288 

320 

352 

384 

416 

448 

480 

 

33  65 

97 

129 

161 

193 

225 

257 

289 

321 

353 

385 

417 

449 

481 

 

34  66 

98 

130 

162 

194 

226 

258 

290 

322 

354 

386 

418 

450 

482 

 

35  67 

99 

131 

163 

195 

227 

259 

291 

323 

355 

387 

419 

451 

483 

 

36  68 

100 

132 

164 

196 

228 

260 

292 

324 

356 

388 

420 

452 

484 

 

37  69 

101 

133 

165 

197 

229 

261 

293 

325 

357 

389 

421 

453 

485 

 

38  70 

102 

134 

166 

198 

230 

262 

294 

326 

358 

390 

422 

454 

486 

 

39  71 

103 

135 

167 

199 

231 

263 

295 

327 

359 

391 

423 

455 

487 

 

40  72 

104 

136 

168 

200 

232 

264 

296 

328 

360 

392 

424 

456 

488 

 

41  73 

105 

137 

169 

201 

233 

265 

297 

329 

361 

393 

425 

457 

489 

 

10  42  74 

106 

138 

170 

202 

234 

266 

298 

330 

362 

394 

426 

458 

490 

 

11  43  75 

107 

139 

171 

203 

235 

267 

299 

331 

363 

395 

427 

459 

491 

 

12  44  76 

108 

140 

172 

204 

236 

268 

300 

332 

364 

396 

428 

460 

492 

 

13  45  77 

109 

141 

173 

205 

237 

269 

301 

333 

365 

397 

429 

461 

493 

 

14  46  78 

110 

142 

174 

206 

238 

270 

302 

334 

366 

398 

430 

462 

494 

 

15  47  79 

111 

143 

175 

207 

239 

271 

303 

335 

367 

399 

431 

463 

495 

 

16  48  80 

112 

144 

176 

208 

240 

272 

304 

336 

368 

400 

432 

464 

496 

 

17  49  81 

113 

145 

177 

209 

241 

273 

305 

337 

369 

401 

433 

465 

497 

 

18  50  82 

114 

146 

178 

210 

242 

274 

306 

338 

370 

402 

434 

466 

498 

 

19  51  83 

115 

147 

179 

211 

243 

275 

307 

339 

371 

403 

435 

467 

499 

 

20  52  84 

116 

148 

180 

212 

244 

276 

308 

340 

372 

404 

436 

468 

500 

 

21  53  85 

117 

149 

181 

213 

245 

277 

309 

341 

373 

405 

437 

469 

501 

22  54  86 

118 

150 

182 

214 

246 

278 

310 

342 

374 

406 

438 

470 

502 

23  55  87 

119 

151 

183 

215 

247 

279 

311 

343 

375 

407 

439 

471 

503 

24  56  88 

120 

152 

184 

216 

248 

280 

312 

344 

376 

408 

440 

472 

504 

25  57  89 

121 

153 

185 

217 

249 

281 

313 

345 

377 

409 

441 

473 

505 

26  58  90 

122 

154 

186 

218 

250 

282 

314 

346 

378 

410 

442 

474 

506 

27  59  91 

123 

155 

187 

219 

251 

283 

315 

347 

379 

411 

443 

475 

507 

28  60  92 

124 

156 

188 

220 

252 

284 

316 

348 

380 

412 

444 

476 

508 

29  61  93 

125 

157 

189 

221 

253 

285 

317 

349 

381 

413 

445 

477 

509 

 

30  62  94 

126 

158 

190 

222 

254 

286 

318 

350 

382 

414 

446 

478 

510 

 

31  63  95 

127 

159 

191 

223 

255 

287 

319 

351 

383 

415 

447 

479 

511 

Dip Switch Position                            DMX  Address 

 

Summary of Contents for ART-575W

Page 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 06 15 17 08 ART 575W Spectrum 575W USER MANUAL ...

Page 2: ...ION 8 Orientation 8 Floor Mounting 8 Truss Mounting 8 Power configuration 9 Wiring the connector 9 Data Cables Linking 9 OPERATING INSTRUCTIONS 10 OPERATING MODES 10 Master Slave Stand Alone 10 Accessing internal programs in Master mode 11 Built in Programs chart 12 DMX Mode 13 Setting the starting address 13 APPENDIX 16 DMX PRIMER 16 Fixture Linking 16 DMX CHANNEL VALUES 17 PHOTO METRICS 18 DIPSW...

Page 3: ... on decal or rear panel of the fixture To prevent risk of fire or shock make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace...

Page 4: ...iable mechanical dimmer 0 100 Variable mechanical zoom 7 40 32 built in color change programs at varying speeds Features Durable and weatherproof IP 54 rated housing Very low noise operation convection cooled look for a fan No control necessary Master Slave operation Frosted lens diffuser Micro stepping motors Thermal switch protection DMX Channel Summary CHANNEL FUNCTION 1 Vector speed 2 Yellow 3...

Page 5: ...6 446 410 445 7 289 2 Front View Side View 528 11 38in 17 6in 16 1in 17 5in Top View 20 8in 428 289 2 326 396 80 150 344 254 100 100 Bottom View 16 9in 13 5in 12 8in 11 4in 5 9in 3 15in 10 0in 3 9in 15 6in Projection angle Carrying handles Product Overview ...

Page 6: ... cloth before installation LAMP INSTALLATION 1 Remove the back cover plate by removing all 8 screws on the rear of the fixture 2 Remove the screws D and E on the lamp plate Pull out the lamp cover plate 3 With lamp socket plate out and the lamp accessible if replacing the lamp remove old lamp first 4 Holding the new lamp by its base align the small pin on the lamp with the small hole in the socket...

Page 7: ...spot by having it widen and spread across the entire spot or moving the hot spot so that it covers as much of the beam spot area as possible Power Warning Verify that the internal multi tap transformer is set to match the line voltage applied and that the proper fuse is installed for the appropriate voltage setting All fixtures must be connected to circuits with a suitable Earth Ground To determin...

Page 8: ...access and routine maintenance Safety cables should always be used The fixture must have a minimum of 1 meter distance from combustible materials FLOOR MOUNTING 1 If connected be sure to always disconnect from main power before installing fixture 2 The ART 575W is constructed with mounting bracket yoke 3 Bolt fixture onto a leveled floor surface using floor mount holes and 3 8 diameter bolts TRUSS...

Page 9: ...Wires Connector Live L Black Brown Yellow or brass Neutral N White Blue Silver Ground W Green Yellow Green Green Consult an electrician if you have any doubts about the proper wiring connection during your installation Data Cables Linking Data linking is required for synchronized operation as well as DMX controller operation The ART 575W fixture is equipped with two 24 AWG data cables that exit th...

Page 10: ...wered the program selected will automatically execute If you own multiple Spectrum fixtures you can link them together so that they all follow one leader in synchrony called the master This operating state is called Master Slave mode The Master Slave mode allows you to link multiple units in a daisy chain fashion In this mode the first unit in the daisy chain will automatically command all other u...

Page 11: ...ue of each switch in the ON position will provide the channel address Determining which switches to toggle ON given a specific channel address can be accomplished in the following manner By subtracting the largest switch value possible from the selected channel address which does not cause a negative number This is the exact method for computing DMX address values as well and this section will be ...

Page 12: ...0 0 Every 60 seconds Rapid Color Change Red Orange Green Cyan Light Blue Blue UV Filter Purple Magenta Auvergne 19 1 1 0 0 1 0 0 0 0 0 Every 5 seconds 20 0 0 1 0 1 0 0 0 0 0 Every 10 seconds 21 1 0 1 0 1 0 0 0 0 0 Every 30 seconds 22 0 1 1 0 1 0 0 0 0 0 Every 60 seconds Smooth Color Change Red Orange Green Cyan Light Blue Blue UV Filter Purple Magenta Auvergne 23 1 1 1 0 1 0 0 0 0 0 Every 5 second...

Page 13: ...dress from 1 to 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 6 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and notate the start addres...

Page 14: ...n DMX mode Therefore each fixture must be spaced and addressed in 8 channel increments as illustrated below The page following contains a cheat sheet which contains all possible DMX address values and associated dipswitch settings ON 1 2 3 4 5 6 7 8 9 10 11 12 1 2 4 8 16 32 64 128 256 DMX values 1 DMX 001 ON 1 2 3 4 5 6 7 8 9 10 11 12 1 2 4 8 16 32 64 128 256 DMX values 2 DMX 009 ON 1 2 3 4 5 6 7 ...

Page 15: ...0 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 ...

Page 16: ...of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whi...

Page 17: ...t Blue Rose Red 5 seconds 10 seconds 30 seconds 60 seconds Smooth Color Change Red Yellow Green Blue Light Blue Rose Red 5 seconds 10 seconds 30 seconds 60 seconds Rapid Color Change Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink 5 seconds 10 seconds 30 seconds 60 seconds Smooth Color Change Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink 5 seconds 10 secon...

Page 18: ... 1 2 2 3 3 0 2900 7200 1250 500 400 320 620 LUX 5 3 10 15 20 25 30 3 64 2 18 7 28 10 92 14 56 18 20 21 84 40 4 4 5 5 6 6 Distance m Diameter m 7 Beampath 1 1 2 2 0 8200 23000 2300 800 620 560 1200 LUX 5 3 10 15 20 25 30 0 61 0 37 1 22 1 83 2 45 3 06 3 67 7 Distance m Diameter m ...

Page 19: ...06 15 17 08 Dipswitch Location Remove fixture front cover clips are located on both sides Front of fixture exposed Dipswitch is accessible without removing PCB cover however a photograph has been taken with the PCB cover removed Dipswitches ...

Page 20: ...n the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid...

Page 21: ...ible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movements...

Page 22: ...t temperature 50 122 F CIRCUIT PROTECTION ART 575W Magnetic Circuit Breaker with GFI Fuse 120V 20mm Glass 15A Fast Blow Fuse 230V 20mm Glass 10A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 8 ORDERING INFORMATION Spectrum 575W ART 575W Technical...