Chauvet Professional FD-105WW User Manual Download Page 7

Page 3 of 18

Ovation FD-105WW User Manual Rev. 4

Introduction

2. Introduction

Description

Ovation FD-105WW is a LED Fresnel wash utilizing data and power sensors to run on both dimming power 

systems and constant power rigs. A zoom range of 8° to 63° and a soft, warm white wash with high CRI 

make it a worthy LED replacement for aging incandescent six-inch Fresnels. Enjoy the benefits of LED 

lighting without being held back by previous investments made in major dimming systems.

Features

Operating modes:

UNO: 8bit Dim: dimmer control

DOS: 16bit Dim: dimmer and fine dimmer control

STD.P: dimmer, dimmer fine, and strobe

6“ warm white LED Fresnel with class leading output 

Soft and even field of light

Works perfectly on conventional dimmers or constant power with DMX

Auto-senses power/data and responds appropriately

Superior low end dimming whether using dimmers or constant power

Perfect fixture for the retrofit market, utilizes existing dimming infrastructure flawlessly

16-bit dimming resolution (DMX mode) for smooth fades

Flat, even field of light, with manual zoom (8-63 deg)

Virtually silent operation for use in any situation

Summary of Contents for FD-105WW

Page 1: ...User Manual ...

Page 2: ... consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the printer to scale the content accordingly Intended Audience Any person installing operating and or maintaining this product should completely read through the guide that shipped with the product as well as this manual before...

Page 3: ...C Plug 6 Power Linking 6 Fuse Replacement 6 DMX Linking 6 DMX Personalities 6 RDM Remote Device Management 6 Master Slave Connectivity 7 Dimmer Modes 7 Mounting 7 Orientation 7 Rigging 7 Procedure 8 Mounting Diagram 8 4 Operation 9 Control Panel Operation 9 Control Options 9 Programming 9 Control Panel Lock 9 Passcode 9 Menu Map 10 DMX Personalities 11 DMX Control 11 DMX Values 11 STD P 11 DOS 11 ...

Page 4: ...vation FD 105WW User Manual Rev 4 ii LED Frequency 13 Power Performance Output Options 13 System Information 13 5 Technical Information 14 Product Maintenance 14 6 Technical Specifications 15 7 Returns 16 8 Contact Us 17 ...

Page 5: ...D 105WW Neutrik powerCON Power Cord Gel Frame 6 25 in 158mm accessories Quick Reference Guide Convention Meaning 1 512 A range of values 50 60 A set of values of which only one can be chosen SET A button on the product s control panel Settings A product function or a menu option Symbol Meaning Electrical warning Not following these instructions may cause electrical damage to the product accessorie...

Page 6: ...ith the specifications in this manual or on the product s specification label To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it Make sure to replace the fuse with another of the same type and rating Never disconnect this product by pulling or tugging on the power cable Operation Do not opera...

Page 7: ...dimming systems Features Operating modes UNO 8bit Dim dimmer control DOS 16bit Dim dimmer and fine dimmer control STD P dimmer dimmer fine and strobe 6 warm white LED Fresnel with class leading output Soft and even field of light Works perfectly on conventional dimmers or constant power with DMX Auto senses power data and responds appropriately Superior low end dimming whether using dimmers or con...

Page 8: ...al Rev 4 Product Overview Control Panel 5 Pin DMX Out Gel Frame Holder Clip Yolk Voltage Input Switch Adjustment Handle Menu Buttons 5 Pin DMX In Power Out 3 Pin DMX Out 3 Pin DMX In Dimmer Control Knob Power In Handle Safety Cable Loop Zoom Control Knob ...

Page 9: ...Page 5 of 18 Ovation FD 105WW User Manual Rev 4 Introduction Product Dimensions 6 65 in 169 mm 12 82 in 325 7 mm 6 31 in 160 3 mm 9 37 in 238 mm 8 06 in 204 8 mm 11 08 in 388 5 mm 15 3 in 388 5 mm ...

Page 10: ... individually with a single DMX controller DMX Personalities The Ovation FD 105WW uses a 3 or 5 pin DMX data connection for the UNO 8bit Dim Dos 8bit Dim 16bit Dim and STD P 8bit Dim 16bit Dim and strobe DMX personalities Refer to the Introduction chapter for a brief description of each DMX personality Refer to the Operation chapter to learn how to configure the Ovation FD 105WW to work in these p...

Page 11: ...ated in the Safety Notes For our CHAUVET Professional line of mounting clamps go to http trusst com products Orientation Always mount this product in a safe position making sure there is adequate room for ventilation configuration and maintenance Rigging Chauvet recommends using the following general guidelines when mounting this product Before deciding on a location for the product make sure ther...

Page 12: ...ing clamp directly You must supply the mounting clamps Make sure the clamps are capable of supporting the weight of this product Use at least one mounting point per product For the CHAUVET Professional line of mounting clamps go to http www trusst com products Mounting Diagram Bracket Mounting Clamps Safety Cables Bracket Adjustment Knob ...

Page 13: ... to the SETTINGS main level 2 Select KEY 3 Select ON or OFF Settings Lock This setting allows activation or deactivation of the menu access lock Activating the menu access lock prevent non authorized personnel from making any changes to the programming levels under the SETTING main level 1 Go to the SETTING main level 2 Select SLOCK 3 Select ON or OFF Passcode After being prompted enter the follow...

Page 14: ...ds DIM2 DIM3 DIM4 CURVE OFF No dimmer CURVE1 Large CURVE3 to small CURVE1 dimmer curves CURVE2 CURVE3 PERFORM LIVE Balances LED cooling using fans and output power level STUDIO Maintains LED cooling by limiting power level SLOCK ON SETTING menu access lock OFF PERSONALITY UNO Selects DMX personality DOS STD P DMX ERROR SAVE Continues last command upon loss of DMX signal BLACK Blacks out product up...

Page 15: ...g address a Go to ADDRESS main level b Select the starting address 001 512 The highest recommended starting address for each DMX mode is as follows DMX Values STD P DOS UNO See the DMX Control section for the highest starting address you can select for each personality Make sure that the starting addresses on the various products do not overlap due to the new personality setting DMX Mode DMX Addre...

Page 16: ...ent knob as follows 1 Press the dimmer adjustment knob above the display twice 2 Select the desired dimmer setting 000 100 0 100 light output by turning the knob clockwise value increases or counter clockwise value decreases Dimmer Speeds This setting determines how fast the output of the Ovation FD 105WW changes when you modify the output value This setting provides four different options to simu...

Page 17: ...he Ovation FD 105WW to factory default settings 1 Go to the SETTING main level 2 Select RESET 3 Enter the passcode and press ENTER to reset the product to its factory settings LED Frequency This option changes the Pulse Width Modulation PWM frequency of the LEDs on the Ovation FD 105WW 1 Go to the SETTING main level 2 Select PWM 3 Select PWM Frequency 600Hz 1200Hz 2000Hz 4000Hz 6000Hz or 25Khz Pow...

Page 18: ...e product 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue 6 Softly drag...

Page 19: ...ducts 13 6 A 14 products 13 6 A 24 products Power I O U S Worldwide UK Europe Power input connector Neutrik powerCON A Neutrik powerCON A Power output connector Neutrik powerCON B Neutrik powerCON B Power Cord plug Edison U S Local Plug Type Color Quantity Power Current Lifespan LED Warm White 1 80 W 2 A 50 000 hours Parameter Value Strobe Rate 0 to 25Hz Color Temperature at full 3197 K Beam Angle...

Page 20: ... RMA number Chauvet will refuse any product returned without an RMA number Once you have the RMA number provide the following information on a piece of paper and place it inside the box Your name Your address Your phone number RMA number A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be your responsibility FedEx ...

Page 21: ...rookhill Road Industrial Estate Pinxton Nottingham UK Website www chauvetprofessional eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Chauvet Europe BVBA Address Stokstraat 18 Email BNLtech chauvetlighting eu 9770 Kruishoutem Belgium Website www chauvetprofessional eu Voice 32 9 388 93 97 Chauvet France Address 3 Rue Ampère 91380 Chilly Mazarin Email FRtech chauvetlighting fr France Websit...

Reviews: