Page 12 of 18
Operation
Ovation FD-105WW User Manual Rev. 4
Loss of Signal Setting
This setting controls how the product responds when the DMX signal is lost.
1.
Go to the
SETTING
main level.
2.
Select
DMX ERROR
.
3.
Choose
BLACK
to turn off the LEDs when the signal is lost or
SAVE
to use the last command
programmed when the signal is lost.
Dimmer Control
The Ovation FD-105WW may be plugged into and controlled using a regular dimmer or by being plugged
into constant power and using DMX control. By default the product is set to
SENS
which automatically
senses the type of power/control being used and sets the product to react accordingly. The product may
also be set to
DMMR
mode which turns off the DMX control and only allows exclusive control of the
product via the dimmer.
1.
Go to the
RUN MODE
main level.
2.
Choose
DMMR
or
SENS
.
Dimmer Menu Control
The Static mode allows for permanent dimmer, zoom, and strobe presets without a DMX controller.
1.
Go to the
STATIC
main level.
2.
Select
DIMMER
.
3.
Select the desired value
0–100
(0-100% light output).
Dimmer - Manual Control
Manually adjust the light output by using the dimmer adjustment knob, as follows:
1.
Press the dimmer adjustment knob above the display twice.
2.
Select the desired dimmer setting
000–100
(0–100% light output) by turning the knob clockwise
(value increases) or counter-clockwise (value decreases).
Dimmer Speeds
This setting determines how fast the output of the Ovation FD-105WW changes when you modify the output
value. This setting provides four different options to simulate the dimming curve of an incandescent lighting
product.
1.
Go to the
SETTING
main level.
2.
Go to the
DIMMER
main level.
3.
Select a dimmer curve (
Off
,
DIM 1
,
DIM 2
,
DIM 3, or DIM 4
).
Dimmer Curves
Select the dimmer curve of the Ovation FD-105WW by selecting the
CURVE
programming level.
1.
Go to the
SETTING
main level.
2.
Select the
CURVE
programming level.
3.
Select dimmer
CURVE 1
,
CURVE 2
,
CURVE 3
(small to large), or
OFF
(linear output).
When SENS and DMMR modes are active, the only control panel button that will
work will be the <ENTER> button which will allow you to change modes.
•
When using the dimmer adjustment knob, the lowest dimmer value stops at
000
and the highest dimmer value stops at
100
.
•
During manual dimmer control, you can also use
<UP>
or
<DOWN>
, which will
cycle through all the dimmer values.
When selecting DIM1–DIM4, the output will correspond to the dimmer curve option
selected under the dimmer curves programming level (CURV).
Summary of Contents for FD-105WW