Page 23 of 29
Rogue Outcast 1 Beam User Manual Rev. 1
O
PERATION
Address
This programming level sets the DMX starting address. In this mode, each product will respond to a unique
starting address from the DMX controller. All products with the same starting address will respond in
unison. This option sets the products DMX address.
1.
Starting from the Main Level screen, select
Address,
press
<ENTER>.
2.
Select the starting address
(001–512)
, press
<ENTER>.
Run Mode
This programming level sets the DMX personality and controls the different test modes.
•
Starting from the Main Level screen, select
Run Mode,
press
<ENTER>
.
DMX Personality
This setting allows you to choose a particular DMX personality.
1.
Highlight
DMX
, press
<ENTER>
.
2.
Select the DMX personality
16CH
or
19CH
, then
press
<ENTER>
.
Auto Test
This option runs every attribute individually through one cycle.
•
Highlight
Auto Test
, press
<ENTER>
.
Manual Test
This option allows each attribute to run individually or as a group.
1.
Highlight
Manual Test
, press
<ENTER>
.
2.
Highlight the desired attribute listed on the control panel screen, press
<ENTER>
.
3.
Set the attribute value (
000–255
), press <
ENTER
>.
4.
Repeat step 2 for the other attributes.
Setup
This programming level controls the product’s head movement, display, dimming, lamp settings, and
maintenance adjustments.
•
Starting from the Main Level screen, select
Setup,
press
<ENTER>
.
Pan Reverse
Reverses the operation of the pan attribute.
1.
Highlight
Pan Reverse
, press
<ENTER>
.
2.
Select
YES
(reverse pan)
or
NO
(normal pan), press
<ENTER>
.
Tilt Reverse
Reverses the operation of the tilt attribute.
1.
Highlight
Tilt Reverse
, press
<ENTER>
.
2.
Select
YES
(reverse tilt)
or
NO
(normal tilt), press
<ENTER>
.
Pan Angle
This option assigns pan range.
1.
Highlight
Pan Angle
, press
<ENTER>
.
2.
Select
540
,
360
, or
180
, press
<ENTER>
.
Make sure that the starting addresses on the various products do not overlap due to
the new personality setting.
The Auto Test will end after one full cycle. You can stop the test by pressing <MENU> at
any time.
When exiting the Manual Test level, the values of all tested channels will revert to zero.