background image

User Manual

Model ID: ROGUER3BEAM

Summary of Contents for 080111732

Page 1: ...User Manual Model ID ROGUER3BEAM...

Page 2: ...n consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the printer to scale the c...

Page 3: ...7 AC Power 7 AC Plug 7 Fuse Replacement 7 DMX Linking 7 DMX Personalities 7 Remote Device Management RDM 7 Mounting 8 Orientation 8 Rigging 8 Procedure 8 Gobo Wheel 9 Color Wheel 10 Lamp Replacement...

Page 4: ...Function 25 Factory Reset Function 25 System Information 26 Offset Mode 26 Pan 26 Tilt 26 Shutter1 26 Shutter2 26 Color 26 Gobo 26 Prism 1 26 Rotating Prism 1 26 Prism 2 26 Rotating Prism 2 26 Focus 2...

Page 5: ...device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the party responsible for compliance coul...

Page 6: ...istance closer than 26 2 ft 8 m is not expected Power and Wiring Always make sure you are connecting the product to the proper voltage in accordance with the specifications in this manual or on the pr...

Page 7: ...000 hours life Fast and precise movement of pan and tilt functions Individually controllable and layerable 8 and 24 facet prisms Frost for even light distribution Tight 1 beam for extremely focused ar...

Page 8: ...Page 6 of 31 Introduction Rogue R3 Beam User Manual Rev 5 Product Dimensions 21 65 in 550 mm 12 79 in 325 mm 8 66 in 220 mm...

Page 9: ...controller DMX Personalities The Rogue R3 Beam uses a 3 pin or 5 pin DMX data connection for the 16 and 19 channel DMX personalities Refer to the Introduction for a brief description of each DMX perso...

Page 10: ...se a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When p...

Page 11: ...Manual Rev 5 Setup Gobo Wheel The Rogue R3 Beam includes one gobo wheel with 17 fixed gobos plus open The diagram shows the gobo number on the wheel as numbered in the DMX Values tables 1 2 3 4 5 6 7...

Page 12: ...anual Rev 5 Color Wheel The Rogue R3 Beam includes one color wheel with 14 fixed colors plus open white as indicated below The diagram shows the color number on the wheel as numbered in the DMX Values...

Page 13: ...an NSL Ushio 300W lamp Follow the procedure below to safely change the lamp Procedure 1 Turn the product off and disconnect it from power Wait at least 15 minutes for the lamp to cool down 2 Remove bo...

Page 14: ...nual Rev 5 3 Orient the bottom of the moving head so that the fan is facing downward 4 Remove the 2 wires connected to the lamp by the spade terminals Using the lamp base push the lamp to the left aga...

Page 15: ...east 5 minutes before switching off the product This will keep the fans running to extract any remaining heat from the product s head DO NOT power cycle the product unless it is necessary DO NOT re st...

Page 16: ...value Press MENU repeatedly to exit to the previous main level Control Panel Lock This setting enables you to activate or disable the control panel lock which keeps unauthorized users from changing t...

Page 17: ...Gobo Prism1 Prism1 Rot Prism2 Prism2 Rot Frost Focus P T Macro P T Ma Speed Special Function Setup Pan Reverse NO Normal pan YES Reversed pan Tilt Reverse NO Normal tilt YES Reversed tilt Screen Reve...

Page 18: ...rs between maintenance Remaining Time NO Shows amount of time remaining in maintenance cycle RESET Resets the time back to the beginning Reset Function Pan Tilt YES NO Reset individual functions or al...

Page 19: ...low to fast 240 250 Random strobe slow to fast 251 255 Open 9 Color wheel see Color Wheel 000 004 Open 005 008 Red 009 012 Orange 013 016 Cyan 017 020 Light green 021 024 Light yellow 025 028 Lavender...

Page 20: ...st 120 123 Gobo 16 shaking slow to fast 124 127 Gobo 17 shaking slow to fast 128 189 Clockwise gobo scroll fast to slow 190 193 Stop 194 255 Counterclockwise gobo scroll slow to fast 11 Prism 1 000 00...

Page 21: ...255 0 100 19 Control 000 069 No function 070 079 Enable pan tilt blackout 080 089 Disable pan tilt blackout 090 099 Enable blackout while color wheel is moving 100 109 Disable color wheel blackout 110...

Page 22: ...132 167 Fast close slow open slow to fast 168 203 Slow close fast open slow to fast 204 239 Pulse strobe slow to fast 240 250 Random strobe slow to fast 251 255 Open 8 Color wheel see Color Wheel 000...

Page 23: ...fast 092 095 Gobo 9 shaking slow to fast 096 099 Gobo 10 shaking slow to fast 100 103 Gobo 11 shaking slow to fast 104 107 Gobo 12 shaking slow to fast 108 111 Gobo 13 shaking slow to fast 112 115 Gob...

Page 24: ...ion runs every attribute individually through 1 cycle Highlight Auto Test press ENTER 14 Frost 000 255 0 100 15 Focus 000 255 0 100 16 Control 000 069 No function 070 079 Enable pan tilt blackout 080...

Page 25: ...e 1 Highlight Tilt Reverse press ENTER 2 Select YES or NO press ENTER Screen Reverse Reverses the screen display 1 Highlight Screen Reverse press ENTER 2 Select YES or NO press ENTER Pan Angle This op...

Page 26: ...ss ENTER 2 Select YES or NO press ENTER Lamp Strike Delay This option sets the duration of time seconds it takes for the lamp to turn on when powering up the product 1 Highlight Ignition Delay press E...

Page 27: ...Tilt Reset This option resets the Pan Tilt functions to the home position 1 Highlight Pan Tilt press ENTER 2 Select YES or NO press ENTER Shutter Prism Reset This option resets the Shutter Prism func...

Page 28: ...the moving parts in the optical path as well as the pan and tilt movements This way when in their home position the moving parts do not show any border or reduce the light output 1 Starting from the...

Page 29: ...ER 2 Select 000 255 press ENTER Frost 1 Highlight FROST press ENTER 2 Select 000 255 press ENTER Mac 4 1 Highlight MAC4 press ENTER 2 Select 000 255 press ENTER Mac 5 1 Highlight MAC5 press ENTER 2 Se...

Page 30: ...the product 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents 4 Clean...

Page 31: ...onsumption 422 W 418 W 411 W 411 W 406 W Operating current 4 20 A 3 55 A 1 98 A 1 78 A 1 68 A Fuse F7A 250 V F7A 250 V F7A 250 V F7A 250 V F7A 250 V Power I O U S Canada Worldwide Power input connecto...

Page 32: ...equest Clearly label the package with an RMA number Chauvet will refuse any product returned without an RMA number Once you have the RMA number provide the following information on a piece of paper an...

Page 33: ...eu Brookhill Road Industrial Estate Pinxton Nottingham UK Website www chauvetprofessional eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Benelux Address Stokstraat 18 Email BNLtech chauvetlig...

Reviews: