53
CHAP. XI
operation of appliances
Your
IntEGrAL CAmPEr
has standard equipment for using
either PROPANE or BUTANE gas
.
Located in a sealed compartment and accessible from the
outside through a hatch:
- a place for a standard cylinder (13 Kg household / 30.6 liters)
- a place for an extra cylinder (13 Kg household / 30.6 liters).
onLY onE CYLInDEr At A tImE IS ConnECtED
to tHE CIrCuIt For StAnDArD VEHICLES
Connection elements:
Standard:
- A flexible gas connector.
-
A low-pressure regulator for adjusting pressure for normal use
at 30 mbar
.
Options
- Depending on version and option, there is an automatic
inverter to ensure initial pressure release and automatically
extract the second cylinder if it has been opened when the
first one is empty.
- A pressure regulator with a built-in collision sensor which
allows operation of the gas installation during travel (see
below for operation).
Located next to the devices (i.e.: in the cupboard under the
sink and refrigerator or under the bed):
- Valves ensure faucet operation and separately cut off
outflow (refrigerator/cooktop/heating and optional oven).
A pictogram indicates their destination.
VALVE OPENING
The valves must be turned in the same direction as
the distribution tube for each device. An arrow on
the valve lets you check its position.
VALVE CLOSING
The valves must be turned perpendicularly to the
distribution tubes for each device.
n
Implementation of the pressure regulator with a built-in
collision sensor
In case of abrupt braking or a collision, the
captor cuts off gas flow.
To reinitialize the collision sensor, press the
GREEN button (rep. in fig. 27) down for a few
seconds.
Make sure the pressure regulator is in a vertical
position.
Test reinitialization by turning on a gas device,
such as the cooktop.
If the device does not operate, repeat the steps
If the device fails to operate after several tries, contact your
dealer / salesperson.
n
GAS CIrCuIt
Fig. 27
a
!
WC
!
WC