background image

6576. B 1905

© 2019 AMETEK Incorporated

Summary of Contents for TCM Series

Page 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Page 2: ...TCM Series Operation Manual Motorized Test Stand Model 100 and 350...

Page 3: ...peration 7 Compression Standard 7 Tension Standard 7 Compression Cycle 8 Tension Cycle 8 Rear Panel Ports and Connections 9 Communication Port 9 USB Port 9 Digital Force Gauge DFG Port 9 Main Power Sw...

Page 4: ...to help you get the most out of your motorized test stand We are constantly updating documentation Manuals Data Sheets Product Release Notes in addition to software and certificates So check back on t...

Page 5: ...nt will occur upon transfer to manual control The actuator or crosshead will immediately respond to manual control settings when the system is placed off line from computer control Before transferring...

Page 6: ...FH 10 32X 63 SS 6539 4 Screwdriver PH 90Deg Offset 6474 1 Power Cable 1 TCM USB to PC USB Cable 3M ForceTest Flash Memory Upgrade SPK TCM 016 1 TCM to DFG Cable RS232 Load Limit Communication to TCM S...

Page 7: ...or Tension arrows The Stop button will end any travel movement of the TCM and the display will flash END To start hold for more than 0 5 seconds Return to Zero RTZ Hold the RTZ button for 0 5 seconds...

Page 8: ...l move down at the set speed The message on the display will flash between DN and the set speed Note The jog speed will always be at unregulated maximum speed 40 in min when jogging away from the test...

Page 9: ...onds will toggle units between in mm in FRONT PANEL INDICATORS AND DISPLAY There are five indicators on the front panel of the TCM used to indicate the crosshead speed speed units mode of operation an...

Page 10: ...ches the adjustable limit switch position If the mechanical limit switch is reached the display will show BOT and the Set Speed to indicate that the lower bottom travel limit switch has been reached F...

Page 11: ...nt to the DFG port The XMIT will stop the TCM only when connected to the Test Stand using the XMIT cable into the DFG Port Tension Cycle When the Tension indicator is illuminated and the Compression i...

Page 12: ...o exchange other forms of data and communicate to external PCs for Data Aquisition purposes as ForceTest Software Digital Force Gauge DFG Port The DFG Port allows the TCM to receive RS232 signals and...

Page 13: ...VAC as its power supply can automatically accommodate 100 240 VAC 50 60 Hz nom inal The appropriate IEC power cord was supplied with the TCM at time of order To install the power cord first plug the...

Page 14: ...s and errors These error codes will be displayed on the same display that indicates the crosshead speed If one of the faults or errors are detected the display will display only the fault error code a...

Page 15: ...les in the base of the machine The template below shows the location of of the two holes and can serve as a guide for drilling two holes in the workbench to receive the two M8 mounting bolts Front M8...

Page 16: ...xtended 69 lbs 31 3 kg approximate X X Shipping Weight Standard 197 lbs 90 kg Extended 209 lbs 94 kg Part Numbering System Model Force Crosshead Travel Height Power Mounting 100 lbf 500 N TCM100 Stand...

Page 17: ...Specifications 14 TCM Operation Manual TCM DIMENSIONS MODE SPEED STOP START Standard 754 0 mm 29 7 in 275 0 mm 10 8 in Extended 1161 0 mm 46 0 in 431 0 mm 17 0 in 108 0 mm 4 3 in See Following Page...

Page 18: ...e Optional Multi Thread Plate Kit p n SPK TCM 005 60 0 2x 9 0 THRU 17 3 x 90 80 0 30 0 0 10 60 0 3x 22 5 2x 9 0 THRU 17 3 x 90 80 0 14 0 6x M6 x1 0 6H THRU 30 0 0 10 3x 45 0 90 0 90 0 10 32 UNF 2B M6...

Page 19: ...ty Multi thread Plate Kit SPK TCM 005 1 T Slot Table SPK TCM 011 1 Foot Switch NC002910 1 Splinter Shield SPK TCM 012 1 Remote Load Cell Adapter Kit SPK TCM 014 1 3 Compression Platen SPK TCM 013 3 Pl...

Page 20: ...on repair or replace the instrument or any part thereof which is defective provided however that this warranty shall not apply to instruments subject ed to tampering or abuse or exposed to highly corr...

Page 21: ...6576 B 1905 2019 AMETEK Incorporated...

Reviews: