background image

®

COUNTRY 4 DIMENSIONS (MM)

14

®

LA 30iB  DIMENSIONS (MM)

0

4

5

1

2

3

FLUE

C

L

154

i/d

200

120

506

265

405

164

59

235

235

619

554

394

547

150° 

charnwood

Boiler tappings are 1" B.S.P. female.
Two each side.

Summary of Contents for LA30iB

Page 1: ...Operating Installation Instructions charnwood ...

Page 2: ......

Page 3: ...Chimney sweeping 6 Boiler Reduction Brick 6 Trouble Shooting 7 CO Alarm 8 Further Help 8 INSTALLATION INSTRUCTIONS Health Safety Precautions 9 Performance 9 Specification 9 Co Alarms 9 Chimney 10 Hearth 10 Preparation of Fireplace 10 Central Heating System 10 11 System Controls 11 Fitting the Fire 12 Flue Connection and Infilling 12 Thermostat 13 Assembly 13 Pre Lighting Check 13 Commissioning 13 ...

Page 4: ...ept is sound and free from any obstructions When using the fire in situations where children or infirm people are present please use a fire guard to prevent accidents The fire guard should be manufactured in accordance with BS 6539 This appliance has been designed to conform with BS EN 13240 and BS EN 13229 FUELS This appliance has obtained the approval of HETAS Ltd for burning approved smokeless ...

Page 5: ...ain the controls fitted to your system and how to operate them ASH CLEARANCE The ashpan should be emptied regularly before it becomes too full The most convenient time to remove the ash is just before riddling the fire since the ash will then be at it s coolest Use the tool provided to remove the ashpan Never allow the ash to accumulate in the ashpan so that it comes in contact with the underside ...

Page 6: ... setting most suitable for the particular fuel used and the draw on the chimney THROAT PLATE AND FLUEWAY CLEANING It is important that the throat plate and all the appliance flueways are kept clean They should be cleaned at least monthly and more frequently if it is found necessary The throat plate and flueways may be cleaned with a low fire still burning Use the scraper tool to scrape any sooty d...

Page 7: ...s or modifications may only be carried out by the Manufacturer or their approved agents Use only genuine Charnwood replacement parts MAINTENANCE Cleaning The appliance is finished in vitreous enamel or high temperature paint To clean the surfaces simply wipe over with a dry cloth or soft brush Abrasive pads and scouring cleaners must not be used as these will damage the finish Care should be taken...

Page 8: ... correctly c a suitable fuel is being used d the fire is not fitted onto a heating system which is too large Fume Emission Warning Note Properly installed and operated this appliance will not emit fumes Occasional fume from de ashing and re fuelling may occur Persistant fume emision is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action...

Page 9: ... these points e Ensure that the boiler reduction brick has not been fitted when it is not required CO ALARM Your installer should have fitted a CO alarm in the same room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning note above IF YOU NEED FURTHER HELP If you need further help with your Charnwood then your Installer will be able to provide the answers...

Page 10: ...installation of Solid Fuel burning appliances flues and chimneys must also be observed PERFORMANCE The rated output for the LA30iB is 6 3 kW 21 500 btu h to water and 2 2 kW 7 500 btu h to the room These are the outputs obtained during testing in accordance with BS 3378 burning Sunbrite Doubles with the doors closed over a 4 hourly re fuelling interval If the optional boiler reduction brick is fit...

Page 11: ...flue pipe is suitable for connecting the fire to the chimney but is not suitable for using for the complete chimney If it is found that there is excessive draw in the chimney then a draught stabilizer should be fitted HEARTH The appliance must be installed on a fireproof hearth The he chimney must not be less than 150mm 6 inches internal diameter or 150 x 150mm internal square positioning of the a...

Page 12: ...ystem the unvalved radiator s on the gravity circuit must have an output of at least 1 0 kW This is to prevent boiling in case of pump failure If the boiler reduction brick is fitted then the appliance may be used for room heating and supplying domestic hot water without the need for a gravity radiator All pipework in the primary circuit must be 28 mm diameter and the gravity flow pipe must rise c...

Page 13: ...wo drops of water are released when a handful of the mixture is squeezed After filling with vermiculite flaunch the top of the flue connector pipe to the chimney with lime mortar Make good the holes in the front and side of the chimney breast making sure that they are completely airtight A typical installation is shown in Fig 11 In most installations it will be possible to sweep the chimney throug...

Page 14: ...reely and easily when the riddling mechanism is operated 2 The plates round the sides and back of the grate must be in position and sitting correctly 3 The throat plate must be fitted in the roof of the appliance COMMISSIONING On completion of the installation and after allowing a suitable period of time for the fire cement and mortar to dry out the fire should be lit and checked to ensure that sm...

Page 15: ... COUNTRY 4 DIMENSIONS MM 14 LA 30iB DIMENSIONS MM 0 4 5 1 2 3 FLUE C L 154 i d 200 120 506 265 405 164 59 235 235 619 554 394 547 150 charnwood Boiler tappings are 1 B S P female Two each side ...

Page 16: ... CG06 Riddler Knob 35 003 RW01 Door L H 13 002 BW20 Riddler Ashpan Tool 36 003 RW02 Door R H 14 002 BW26 Door Opening Tool 37 009 LA30IB A Firebox Boiler Assy LA30iB 15 008 BW50 Thermostat Knob 38 011 AV09 Boiler Reduction Brick Optional Extra 16 002 FW07 Front Firebar 39 012 FW34 Scraper Tool 17 002 FW08 Deepening Bar 40 008 RW09 Secondary Air Flap 18 002 AV31 Throat Plate 41 010 AV12 150 Flue Pi...

Page 17: ... CO in combustion products Flue gas temperature Heat Output Space Boiler Energy efficiency Fuel types A Division of A J Wells Sons Limited Registered in England No 03809371 14 Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS SONS LTD A J WELLS SONS LTD AV44 CPD 2015 100 mm 200 mm 0 66 309 C 2 2 kW 6 3 kW 75 9 Solid Fuel 16 ...

Page 18: ......

Page 19: ......

Page 20: ...r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r REV LA 30IB 03 15 Issue L ...

Reviews: