background image

Insert the lower

mounting screws

into the lower wall

plugs through the

corresponding

depressed holes in

the lower part of the

back panel. Do not

tighten fully.

Before tightening the

wall mounting screws fully, at this stage it is recommended to check the

horizontal alignment of the appliance with a spirit level, as small adjust-

ments can still be made if necessary. When this has been checked,

tighten all four fixing screws fully.  

To access the upper fixing screws insert a screwdriver through the

holes in the deflector plates above the catalyst as shown in figure 6.

There are no imitation fuel bed components to install. The appliance
features a ribbon burner which is designed to produce a continuous
band of flame over its length. The burner should be visually inspected
to ensure it is free from any foreign matter. If it is necessary to clean or
dust off the burner then the glass door should be removed by removal
of the four retaining screws. Re-fit the glass door after cleaning or
inspection, ensuring a good seal.

The front section of the frame assembly should now be re-fitted. Re-
fitting is the reverse of removal as detailed in section 8.0.

A qualified gas appliance installer must connect the gas room heater to
the gas supply.
Consult all local codes. Route gas line using techniques and materials
prescribed by local and/or national codes. Only use pipe of 1/2" or
greater diameter to allow full gas volume to the gas fireplace. Undue
pressure loss will occur if the pipe is too small.

An ANSI approved manual shut-off valve and union must be installed
upstream of the heater within the fireplace cavity when rigid pipe is
used. Ensure that a sediment trap is installed upstream of the heater
(figure 7) within the structure’s piping system to prevent moisture and
contaminants from passing through the pipe to the heater controls and
burner. Failure to do so could prevent the heater from operating reliably.

The heater gas inlet connection is 3/8” NPT at the regulator, located
below the burner, in the right hand side of the heater. When tightening
up the joint to the regulator hold the regulator securely with a wrench to
prevent the regulator from moving. 

Turn on gas supply and test for gas leaks using a gas leak test solution
(also referred to as bubble leak solution).
NOTE: using a soapy water solution (50% dish soap, 50% water) is an
effective leak test solution, but it is not recommended, because the
soap residue that is left on the pipes/fittings can result in corrosion over
time. 

A. Light the appliance (refer to the lighting instructions label in the con-
trol compartment or on page 9).

B. Brush all joints and connections with the gas leak test solution to
check for leaks. If bubbles are formed, or gas odor is detected, turn the
gas control knob (off/pilot/on) to the “OFF” position. Either tighten or
refasten the leaking connection, then retest as described above.

C. When the gas lines are tested and leak free, be sure to rinse off the
leak testing solution.

D. Observe the individual tongues of flame on the burner. Make sure all
ports are open and producing flame evenly across the burner. If any
ports are blocked, or partially blocked, clean out the ports.

The heater regulator
controls the burner
pressure which
should be checked at
the pressure test
points located on the
control valve itself
(shown in figure 8) for
burner (manifold) and
regulator setting
pressure.
The valve is found on
the centre of the
appliance behind the
valve cover. 

6

9.0 MOUNTING THE APPLIANCE - continued

10.0 CHECKING THE BURNER

11.0 FINAL FITTING OF THE FRAME ASSEMBLY

12.0 CONNECTING A GAS LINE

13.0 CHECKING THE GAS CONNECTIONS

IMPORTANT: HOLD HEATER REGULATOR WITH A
WRENCH TO PREVENT MOVEMENT WHEN CONNECTING
TO INLET PIPING.

Figure 6

Figure 7

14.0 GAS PRESSURE CHECK

Burner
(Manifold)
pressure

Regulator
pressure
setting

Figure 8

Summary of Contents for F500070

Page 1: ...alled Appliance WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER WARNING DO NOT BUILD A WOOD FIRE DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES This is an unvented gas fired heater It uses air oxygen fr...

Page 2: ...y not be operating correctly 2 Section Contents Page No 1 0 General Information 2 2 0 Inventory 2 3 0 Appliance Data 2 4 0 Important Safety Information 2 5 0 Codes 3 6 0 Combustion and Ventilation Air 3 7 0 Site Requirements 4 8 0 Preparing the Appliance 5 9 0 Mounting the Appliance 5 10 0 Checking the Burner 6 11 0 Final Fitting of the Frame Assembly 6 12 0 Connecting a Gas Line 6 13 0 Checking t...

Page 3: ...ned from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit This Focal Point Unvented Gas Room Heater is certified by OMNI Test Laboratories Inc t...

Page 4: ... as a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distance of 20 of the appliance sides No such materials are permitted directly above the appliance regardless of distance The minimum clearance to the ceiling above the appliance is 32 measured from the top of the appliance glass panel Combustible mat...

Page 5: ...d on a studded wall with conventional 16 stud spacing then a wall mounting plate is supplied to enable this First locate the studs and using suitable fixings screw the mounting plate to the wall via the four mounting holes The heater may then be hung onto the mounting plate The bottom of the heater may be secured onto the lower mounting studs using the wingnuts or the hex nuts provided Mark the po...

Page 6: ...h the pipe to the heater controls and burner Failure to do so could prevent the heater from operating reliably The heater gas inlet connection is 3 8 NPT at the regulator located below the burner in the right hand side of the heater When tightening up the joint to the regulator hold the regulator securely with a wrench to prevent the regulator from moving Turn on gas supply and test for gas leaks ...

Page 7: ...Inspect the burner and the catalysts and clean if necessary with a soft brush 5 Disconnect the gas supply 6 Undo the four screws retaining the burner support brackets to the base and rear of the firebox 7 Remove the burner unit strip off the burner pipes and clean thoroughly 8 Clean the in line restrictor pilot assembly and the burner tube Do not attempt to remove the pilot injector as this can ca...

Page 8: ...es Position gas sample probe directly over a cata lyst via the outlet grille on top of the appliance Record the carbon diox ide CO2 concentration and then the carbon monoxide CO concentration as displayed by the analyzer also noting the units in which the values are expressed Most analyzers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per...

Page 9: ...under section B above If you do not smell gas go to next step 6 The pilot is located on the left side behind the burner Figure 11 7 Depress control knob in and turn counterclockwise to the SPARK position Figure 10 and hold there for a few seconds Note If you are running the heater for the first time or after an extended period of non use it will be necessary to press the control knob all the way i...

Page 10: ... fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all isolators are adequately sized and fully open Check meter pressure is adequate If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effec...

Page 11: ...ner fixing points WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY As our policy is one of continuous improvement and development we hope therefore you will understand we must retain the right to amend details and or specifications without prior notice DO00555...

Reviews: