The appliance must be prepared for

installation by removing the front

decorative frame, removing the selected

gas inlet ‘knock-out’, and assembling and

fitting the rear frame to the appliance.

These steps are carried out as follows:

1. 

The decorative fire frame assembly

comprises of three parts, the front frame,

the rear frame and the outlet grille. 

Remove the front frame retaining screws

(positions shown in figure 1)  from the side

of the firebox and carefully remove the

front frame from the appliance.  Remove

the wall mouting plate from the appliance

by removal of the two wingnuts located in

the lower inner secion of the firebox.

2. 

Gas connection :The heater gas inlet

connection is 3/8” NPT at the regulator,

located below the burner, in the right

hand side of the heater. There are four

possible entry points for the gas supply pipework to enter the appliance

firebox. These entry points are ‘knock out’ type holes (shown in figure 2).

Non-concealed gas connections may be made using the entry points at

either end of the firebox or the one in the bottom of the firebox. A concealed

gas connection may be made using the knock out hole in the centre back

of the firebox. Select

the most appropriate

entry point and knock

out the relevant hole. 

If a concealed gas con-

nection is to be made,

the supply pipe should

always be sleeved

through walls and

floors using the

shortest possible route. 

For concealed supply

pipe routing, pipes

must (where possible) be vertical and providing there is sufficient wall thick-

ness available, they should be placed in pipe chases. Horizontal pipe runs

should be avoided.  Prior to chasing a solid wall, an inspection should be

made to note the proximity of any cables/sockets outlets which may already

be buried. Pipes must be secured using suitable clips and protected against

corrosion. Ideally factory finished protected pipework and fittings should be

used. Joints should be kept to a minimum and compression fittings must

not be used. The pipework installation must be tested for soundness before

any protection is applied and/or the pipework and fittings are buried.

Now it is necessary to

assemble the rear frame

of the appliance. Unpack

the four frame sections

and lay face down on a

soft surface taking care

not to damage the painted

finish. Using the eight self

tapping screws provided,

fasten the frame pieces

together as shown in fig-

ure 3, making sure that

the edges align neatly. 

With the rear frame
assembled, and  the
main firebox lying
with the glass panel
downwards,  attach
the rear frame to the
main firebox using
four self tapping
screws in the
positions shown in
figure 4.

After having

selected the

final mounting

position of the

appliance, tak-

ing into account

the site

requirements as

specified in

section 7 of

these

instructions, the

integrity of the

wall, and the

feasibility of the

proposed

supply  pipe

routing, the appliance firebox may be secured to the wall. 

A full size fitting template is supplied to assist with wall mounting. 

If the heater is to be installed on a studded wall with conventional 16”

stud spacing then a wall mounting plate is supplied to enable this. First

locate the studs and using suitable fixings, screw the mounting plate to

the wall via the four mounting holes. The heater may then be hung onto

the mounting plate. The bottom of the heater may be secured onto the

lower mounting studs using the wingnuts or the hex nuts provided. 

Mark the positions shown as “Plasma/Capella/Radium fixing points on

the wall.  If the appliance is to be mounted on the inner leaf of a con-

ventional cavity wall, or a solid wall, drill four holes using a 1/4” masonry

bit. Insert the fiber wall plugs provided.

If the appliance is to be mounted on a dry lined wall or a timber framed

construction wall then special cavity screw fixings will be required which

are not supplied with this product. These should be constructed from

metal and not plastic.

If a concealed gas connection is to be made ensure the gas supply pipe

is in it’s final position and can enter the appliance in the correct position

when the appliance is hung on the wall.

Insert the wall mounting screws into the top wall plugs, taking care to

leave the screws protruding approximately 3/8” from the wall. Now hang

the appliance onto these screws through the two keyhole shaped holes

in the back panel of the appliance. 

8.0 PREPARING THE APPLIANCE

9.0 MOUNTING THE APPLIANCE

13.8 (350mm)

FI

RE

BO

X O

U

TLI

NE

CO

N

TO

RNO

 DE

 LA

CA

M

A

RA

 DE

COM

B

U

STI

ON

PL

AS

M

A

/C

AP

EL

LA

RA

DI

UM

 

CE

NTRE

 LI

NE

FOCAL POINT

 WALL MOUNTED

CATALYTIC VENT FREE

GAS FIRE RANGE

FITTING TEMPLATE

DO NOT RECESS OR

INSET ANY PART OF

THE FIRE.

0.5

(13mm)

FOCAL POINT

PLANTILLA PARA LA

INSTALACION DE LA

GAMA DE CHIMENEAS

DE GAS CATALITICAS

DE PARED SIN SALIDA

DE HUMOS

NO EMPOTRE NINGUN

ELEMENTO DE ESTA

CHIMENEA

LI

NE

A

 DE

CENTRO

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

REFLECTION, ATHOS, NEON, SCANDIUM

AND PLASMA / RADIUM

MOUNTING PLATE

PLACA DE MONTAJE

F860033 ISSUE A  -  24/4/06

WALL MOUNTED VENT FREE

FITTING TEMPLATE

PLANTILLA PARA LA

INSTALACION DE

CHIMENEAS DE PARED SIN

SALIDA DE HUMOS

IMPORTANT

THIS FIRE IS TO BE WALL HUNG ONLY.  DO NOT RECESS OR INSET ANY PART OF THE FIRE.

THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.  DO NOT INSTALL THE FIRE WITH THIS TEMPLATE IN PLACE.

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED. NO EMPOTRE NINGUN ELEMENTO DE ESTA CHIMENEA.

ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION. RETIRE LA PLANTILLA ANTES DE COLOCAR LA CHIMENEA.

PIERCE TEMPLATE 

TO MARK HOLE

POSITION

ON WALL X 4

(ALL MODELS)

PERFORE LA

PLANTILLA PARA

MARCAR LA POSICION

DE LOS 4 TALADROS

EN LA PARED

(TODOS LOS MODELOS)

FIXING POINTS:

PUNTOS DE SUJECION:

PLASMA, CAPELLA, RADIUM

WHEN MOUNTING PLATE IS NOT USED

SI NO SE UTILIZA LA PLACA DE MONTAJE

CONCEALED GAS INLET

(ALL MODELS)

ENTRADA DE GAS OCULTA

(TODOS LOS MODELOS)

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

16 (406mm)

CONCEALED GAS INLET

ENTRADA DE GAS OCULTA

REFLECTION, ATHOS,

NEON, SCANDIUM

17.2

(437mm)

18

(457mm)

"

"

"

"

"

WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY
INTO THE FIREPLACE. AVOID ANY DRAFTS THAT ALTER
BURNER FLAME PATTERNS.

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Summary of Contents for F500070

Page 1: ...alled Appliance WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER WARNING DO NOT BUILD A WOOD FIRE DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES This is an unvented gas fired heater It uses air oxygen fr...

Page 2: ...y not be operating correctly 2 Section Contents Page No 1 0 General Information 2 2 0 Inventory 2 3 0 Appliance Data 2 4 0 Important Safety Information 2 5 0 Codes 3 6 0 Combustion and Ventilation Air 3 7 0 Site Requirements 4 8 0 Preparing the Appliance 5 9 0 Mounting the Appliance 5 10 0 Checking the Burner 6 11 0 Final Fitting of the Frame Assembly 6 12 0 Connecting a Gas Line 6 13 0 Checking t...

Page 3: ...ned from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit This Focal Point Unvented Gas Room Heater is certified by OMNI Test Laboratories Inc t...

Page 4: ... as a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distance of 20 of the appliance sides No such materials are permitted directly above the appliance regardless of distance The minimum clearance to the ceiling above the appliance is 32 measured from the top of the appliance glass panel Combustible mat...

Page 5: ...d on a studded wall with conventional 16 stud spacing then a wall mounting plate is supplied to enable this First locate the studs and using suitable fixings screw the mounting plate to the wall via the four mounting holes The heater may then be hung onto the mounting plate The bottom of the heater may be secured onto the lower mounting studs using the wingnuts or the hex nuts provided Mark the po...

Page 6: ...h the pipe to the heater controls and burner Failure to do so could prevent the heater from operating reliably The heater gas inlet connection is 3 8 NPT at the regulator located below the burner in the right hand side of the heater When tightening up the joint to the regulator hold the regulator securely with a wrench to prevent the regulator from moving Turn on gas supply and test for gas leaks ...

Page 7: ...Inspect the burner and the catalysts and clean if necessary with a soft brush 5 Disconnect the gas supply 6 Undo the four screws retaining the burner support brackets to the base and rear of the firebox 7 Remove the burner unit strip off the burner pipes and clean thoroughly 8 Clean the in line restrictor pilot assembly and the burner tube Do not attempt to remove the pilot injector as this can ca...

Page 8: ...es Position gas sample probe directly over a cata lyst via the outlet grille on top of the appliance Record the carbon diox ide CO2 concentration and then the carbon monoxide CO concentration as displayed by the analyzer also noting the units in which the values are expressed Most analyzers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per...

Page 9: ...under section B above If you do not smell gas go to next step 6 The pilot is located on the left side behind the burner Figure 11 7 Depress control knob in and turn counterclockwise to the SPARK position Figure 10 and hold there for a few seconds Note If you are running the heater for the first time or after an extended period of non use it will be necessary to press the control knob all the way i...

Page 10: ... fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all isolators are adequately sized and fully open Check meter pressure is adequate If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effec...

Page 11: ...ner fixing points WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY As our policy is one of continuous improvement and development we hope therefore you will understand we must retain the right to amend details and or specifications without prior notice DO00555...