INTRODUCTION
The PARAGON SLIMLINE 3 Slide incorporates a single gas control, which selects ignition pilot, low or high settings. It is
operated via a slide lever on the upper right hand side of the appliance.
The appliance incorporates a safety device in the form of an Oxygen Depletion System, which constantly monitors the
oxygen in the room and will cause the fire to switch off if the oxygen level reduces, for instance due to insufficient
ventilation or a blocked flue.
If this regularly occurs do not attempt to relight the appliance until a qualified engineer has checked it, the problem may
not be due to lack of air or a defective flue.
A fire front (fret) must be used with this appliance.
SECTION TWO Operating the Appliance (user instructions)
The full lighting procedure is as follows: -
A.
Push slide control lever down, as far as possible a clicking noise will be heard and pilot will light, HOLD DOWN
FIRMLY FOR ABOUT 20 SECONDS.
B.
Pull lever up and the pilot light should remain alight and the main burner should light on its low setting.
C.
Should the pilot fail to light, pull the lever fully up to turn off the appliance, wait 3 minutes and repeat the
procedure (a &b). If the pilot does not light and no clicking noise is heard replace the battery and try again.
D.
After lighting the pilot flame and the main burner on its low setting the control lever may be lifted until slight
resistance is felt, this will put the burner on its high setting.
E.
To completely extinguish the fire, pull the lever up past the resistance to its fullest extent. The fire may be
operated on either its low or high setting.
F.
It is recommended that the appliance be operated on its high setting for a short period before adjusting to the
low setting.
G.
If the ignition does not operate fit a new 9V battery (PP3/MN1602) to the ignition unit, located behind the fret
adjacent to the gas inlet pipe, and repeat ignition procedure prior to reporting a fault.
Note: - If the ignition fails the pilot can be lit with a taper or a match held at the pilot head.
Remove fret for access and replace after lighting.
If the fire has extinguished for any reason wait 3 minutes before relighting.