SECTION NINE CONNECTING THE GAS SUPPLY
TURN OFF ANY GAS APPLIANCES THAT ARE FED BY THE METER AND ISOLATE THE GAS SUPPLY BY TURNING OFF AT
THE METER.
The Gas Connection can be made by removing the gas inlet
cover located on the left hand side of the fire box sump
assembly. Remove the 8 off fixing screw and remove the
plate plus gasket. Please note special attention should be
taken not to damage the gasket.
You will then have access to the isolating cock which is
fitted in the supply feed.
When a concealed gas fitting from the rear is required it is
necessary to route the pipe to the left side of the unit,
taking into account the requirements of BS 6891 1988
dealing with enclosed pipes.
When installing the firebox into a cavity wall, any part of
the installation pipe work installed in the void open to the
cavity wall must be enclosed in a gas tight sleeve. It must be sealed at the point at which the sleeved
installation pipe enters the fire (The Gas Safety (Installation and Use) Regulations Certificate of exemption
number 1 of 1996). Where the pipe enters the fire the outer sleeve must be sealed to the grommet and the
pipe must be sealed to its outer sleeve using suitable mastic.
CHECK BURNER PRESSURE AND GENERAL OPERATION
Remove the screw from the pressure test point on the burner inlet elbow and fit a pressure test gauge.
Turn on the gas to the appliance and operate as described in section three. Check that the inlet pressure
/- 1 mbar for natural gas.
Turn off the appliance and remove pressure test gauge.
Refit the screw into the pressure test point and turn on the appliance again, check that the screw has sealed
with leak detection fluid.
Turn the appliance off.
Refit the gas inlet cover and gasket.
Please note special attention should be taken
not to damage the gasket, and ensure an adequate seal is made.
Power lead routing
The power supply for this appliance is provided via AC power adaptor 230 VAC. The main cable terminates
at the rear Right hand side of the fire box. The length of the cable provided with the appliance is 1.65
metres. Care must be taken when siting the fire box not to trap the exposed main cable within the builders
opening.
Note: the power cable link to the transformer must be accessible for repairing handset and use with the
battery holder
The cable can be routed using the following two methods,
Method 1
Passing the cable through the side of the chimney breast. It is good practice to run the cable within a
sleeve of at least 15mm internal diameter, sealing the sleeve using a suitable sealant at the point the
sleeve / cable terminates the chimney masonry.