12
Bakechef Range
Issue 01 06/21
6.0
Technical Data & Declaration of Performance (DoP)
Manufacturer:
Charlton & Jenrick Ltd.
Range Designation:
Go Eco Bakechef stoves.
Models:
Go Eco Bakechef stove with nominal output of 5kW.
Intended Use:
Domestic heating appliances and solid fuel cooking appliances.
Independently Performance & Safety tested by:
Kiwa Gastec, UKCA NB No: 0558, Kiwa Cermet Italia CE NB No: 0476
Constancy of Performance System:
ISO9001
Signed:
Peter Mintoft
Director
June 2021
NOTE:
Refuelling intervals for testing are chosen according to the standards concerned for performance testing and are
comparative only. They
do not
relate directly to re-fuelling intervals that can be achieved on an installed product. Re-fuelling
intervals of 1h for wood and 3-4+ hours for briquetted smokeless fuels would be more usual. Under normal conditions on a low air
control setting stoves should stay in overnight on suitable briquetted smokeless fuel.
Model
Go Eco
Bakechef
Notes
Appliance weight (packed/unpacked) (Kg):
224/203
Approximate Output Range: (kW)
3.8-6.3
Harmonised EN European Standard (hEN):
EN13240: 2001
Amd 2: 2004
EN12815:2001+
A1:2004
Additional Characteristics Test Standard:
DIN +
Additional Particulate Emission Test Standard:
PD6434
Additional cooking/oven tests
EN 12815: 2001
Heating 2000g water to boiling
<12 mins
Oven Cooking - Shortbread
Pass
Performance Characteristics using
Wood
Fuel
Test Report Issue Date:
06/21
Total Efficiency: (%)
82.5
Declared nominal output: (kW)
5.0
Tested nominal Output: (kW)
5.0
Tested wood re-fuelling interval: (h)
0.80
Flue gas mass flow: (g/s)
4.8
Mean CO emission (@13% O
2
) : (%)
(Nmg/m
3
)
0.07
(875)
Mean C
n
H
m
emission (@13% O
2
): (Nmg/m
3
)
32
Mean NOx emission (@13% O
2
): (Nmg/m
3
)
103
DIN+ particulates (@13% O
2
): (Nmg/m
3
)
26
PD6434 Particulate Emissions High output: (gh
-1
)
2.4
PD6434 Particulate Emissions Low output: (gh
-1
)
1.5
Optical Density Time > 0.2 High (Mins)
0
Optical Density Time > 0.2 Low (Mins)
0.5
*Mean Flue Temperature: (Deg C)
210
Approximate Max Log Length: (mm)
350
ClearSkies Mark Level
5
EEI Labelling Category
A+
Clearances from Combustible Materials
Side Wall: (mm)
300
Rear Wall: (mm)
75/350