Calibration

The AC Outlet Analyser and Wrist Strap Tester is calibrated 

to NIST traceable standards.  Calibration may be performed 

to ensure that the tester is operating within limits.  We 

recommend annual calibration of our testers.

TESTING THE WRIST STRAP TESTER

A. LOW FAIL -

   Connect a 675 kilohm resistor @ 5%

 

 

tolerance between the Wrist Strap Test

 

 

Jack and the Test Plate.  The Wrist Strap

 

 

Test LED will momentarily illuminate then

 

 

turn off.  This test confirms the LOW FAIL

 

 

point.

B. LOW PASS -

  Connect a 825 kilohm resistor @ 5%

 

 

tolerance between the Wrist Strap Test

 

 

Jack and the Test Plate.  The Wrist Strap

 

 

Test LED will remain illuminated until the

 

 

resistor is removed from the Test Plate.

 

 

This test confirms the LOW PASS point.

C. HIGH PASS -

 Connect a 32 megohm resistor @ 5%

 

 

tolerance between the Wrist Strap Test

 

 

Jack and the Test Plate.  The Wrist Strap

 

 

Test LED will remain illuminated unitl the

 

 

resistor is removed from the Test Plate.

 

 

This test confirms the HIGH PASS point.

D. HIGH FAIL -

  Connect a 40 megohm resistor @ 5%

 

 

tolerance between the Wrist Strap Test

 

 

Jack and the Test Plate.  The Wrist Strap

 

 

Test LED should not illuminate.  This test

 

 

confirms the HIGH FAIL point.

Specifications

Input Voltage:

  220 VAC ±15%

Current Drain:

 

  < 10mA

Operator Resistance Limits (nominal):

  750 kilohms - 35 megohms

Test Voltage, Open Circuit:

  27 VDC (nominal) 

 

Long Term Drift:

  < . 1% / decade

Dimensions:

  5.1 cm x 7.6 cm x 5.1 cm (Item 

99142

)

  6.9 cm x 11.3 cm x 5.3 cm (Item 

99143

)

Operating Temperature:

  0° - 40°C

Limited Warranty

Charleswater expressly warrants that for a period of one (1) year 

from the date of purchase, Charleswater AC Outlet Analysers will be 

free of defects in material (parts) and workmanship (labor). Within the 

warranty period, the product will be tested, repaired or replaced at 

Charleswater’s option, free of charge. Call Customer Service at 00 44 (0) 

1892-665313 for a Return Material Authorisation (RMA) and for proper 

shipping instructions and address.  You should include a copy of your 

original packing slip, invoice, or other proof of purchase date.  Any unit 

under warranty should be shipped prepaid to the Charleswater factory. 

Warranty replacements will take approximately two weeks.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU 

OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND 

IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY 

DISCLAIMED. The express warranty will not apply to defects or 

damage due to accidents, neglect, misuse, alterations, operator 

error, or failure to properly maintain, clean or repair products.

Limit of Liability

In no event will Charleswater or any seller be responsible or liable 

for any inury, loss or damage, direct or consequential, arising out 

of the use of or the inability to use the product. Before using, users 

shall determine the suitability of the product for their intended use, 

and users assume all risk and liability whatsoever in connection 

therewith.

Reviews: