background image

 

LT-FSDC 

 

2

nd

 Printing 

Page 9 of 13 

 

4.4

 

Route Drop Cable into Closure 

Step 

Number 

Instruction 

Locate the drop cable ports on the front of the 
closure. The FSDC tool bag includes a drop 
port nut tool specially fit for removing and 
tightening the nuts that seal these ports. 

 

For those drop ports that will be used, remove 
the nut and set it aside.  

 

Note: all drop ports have a thin membrane 
inside that helps to seal from environmental 
intrusion. If a drop port will not be used in the 
installation, then DO NOT PIERCE this 
membrane.   

 

The FSDC includes three sizes of drop port 
grommets:  small (for 3-4 mm cable), medium 
(for 5-6 mm cable), and large (for flat drop 
cable).   

The standard unit (FSDC4T16SA8L8MV) is 
configured with eight large grommets in the 
top row of drop ports and eight medium in the 
bottom row of drop ports. If other drop 
grommets are needed, order the grommet 
retrofit kit.  

 

If using un-connectorized drop cable, then run 
the cable through the grommet. 

 

If using preconnectorized drop cable, then cut 
a slit through the side of the grommet and 
insert the cable into the grommet. 

 

Route the drop cable through the drop cable 
port into the FSDC. 

 

If using unconnectorized cable, terminate a 
connector onto the end of the cable. 

 

Plug the connector into the drop side adapter 
that corresponds to the appropriate feed fiber 
connection. 

     

 

Push the grommet into the drop cable port. 

 

Reattach the drop cable port nut. Use the 
tightening tool to tighten the nut just until snug. 
Overtightening may push the nut past its 
sealing point and possibly damage the threads 
on the nut. 

 

Tip: when installation is complete, use Velcro 
or some other fastener to secure the nut 
tightening tool inside the closure for future 
use. 

 

 

 

Summary of Contents for FSDC Series

Page 1: ...cument Purpose This document provides installation instructions for the Charles Fiber Sealed Drop Closure FSDC A typical FSDC is shown in Figure 1 NOTE Hereafter the Charles Fiber Sealed Drop Closure Series will be referred to as the FSDC or closure 1 2 Product Purpose The FSDC a sealed splice closure IP68 rated used in fiber splicing applications where a single feed fiber must be split into multi...

Page 2: ...s fibers and place them in a specifically designated container Do not consume any food products near the cable installation site Corrugated metal or armor in feed cables is very sharp when cut or exposed Exercise extreme caution to prevent personal injury Use protective work gloves when handling armored cable CAUTION Perform all bonding and grounding prior to making any electrical and communicatio...

Page 3: ...wdriver to pry open the four hinged latches that hold the FSDC closed Note The accessory bag includes a closure cover stop which can be placed in the door hinge to hold the door securely open 2 Locate the express port oval port on the bottom of the FSDC Use a 5 mm or 3 16 Allen wrench to remove the sealing components Note The express port can accommodate cable with OD from 10 to 17 5 mm 0 394 to 0...

Page 4: ...nder the clamps using a Philips screwdriver to tighten the clamps in place Use a 6 mm hose clamp on each cable to secure in place clamps included in the accessory bag 8 Take the plastic inner gasket and connect the pieces around the sheathed cables Push this grommet inward into the express loop port Fit the rubber middle gasket around the cables Push this gasket inward into the express loop port 9...

Page 5: ... the FSDC until the cable sheathing is inside Note if the cable is not snug use sealing tape Push the grommet inward into the branch cable port Use the branch port wrench to fully tighten the branch port nut into position 3 Guide the strength member under the clamps using a Philips screwdriver to tighten the clamps in place Use the 6 mm hose clamps included in the accessory bag to secure the cable...

Page 6: ...a connectorized splitter connect the output legs of the splitter or drop legs of the tap by plugging these connectors into the back side of the adapter panel inside the closure With fiber stubbed output legs the fiber must be spliced to the drop cable fiber 4 3 1 Using the FSDCBT BS 2S Versions with Charles Hinged Trays The FSDCBT can accept either two short 4 x6 splice trays or one long 4 x9 spli...

Page 7: ...oid kinking as the trays are lifted and lowered 4 3 2 Using the FSDC4T Version with Four Mini 5 x4 Trays Step Number Instruction 1 Separate a single buffer tube from the cable bundle to be used in splicing operations 2 Route this buffer tube into both sides of the splicing tray Route buffer tube slack into the slack storage area underneath all the splicing trays 3 Mark the points of the buffer tub...

Page 8: ...g operations to splice the selected fiber to the splitter fiber splicing not pictured Place a cover on the splicing tray At this point anchor the buffer tubes using cable ties inside the closure 6 Connect the splitter fibers to the feed side top side of the adapters found under the splicing trays ...

Page 9: ...of drop ports and eight medium in the bottom row of drop ports If other drop grommets are needed order the grommet retrofit kit If using un connectorized drop cable then run the cable through the grommet If using preconnectorized drop cable then cut a slit through the side of the grommet and insert the cable into the grommet 3 Route the drop cable through the drop cable port into the FSDC If using...

Page 10: ...h Ensure that the hand is entirely clear of the interior side Figure 4 2 Push the latch toward the center of the FSDC until the latch snaps into place Figure 5 3 When all latches are closed use an Allen wrench to tighten the securing screws in the upper right and left corners of the FSDC This tightens the latches to ensure a proper seal Figure 6 Figure 4 Closing the Hinged Latch Figure 5 Latch Aft...

Page 11: ...ung over the strand 6 Tighten the clamps around the strand to suspend the FSDC Figure 9 The tap brackets can accommodate strands of 1 4 to 3 8 diameter 4 6 2 Pole Mounting with Bands To mount the FSDC on a pole with bands order the pole mounting kit 97 FSDCPLKTA which includes two mounting brackets and two mounting bands 1 Attach the pole mounting brackets using the included mounting bolts on the ...

Page 12: ... the pole for drilling 3 Drill holes for lag bolts 4 Use customer supplied lag bolts and washers to secure the FSDC to the pole 4 6 4 Wall Mounting The FSDC can be wall mounted using the pole mounting bracket kits To mount horizontally use kit 97 FSDCPLKTA Figure 12 To mount vertically use kit 97 FSDCPLKTB Figure 13 The installer must supply corrosion resistant expansion screws or anchors appropri...

Page 13: ...6 hinged splice FSDC2S16SA8L8MV FSDC Closure with bracket for Charles hinged trays 16 SC APC adapters 8 large and 8 medium drop port grommets air valve includes two 4 x6 hinged splice Optional Equipment 97 FSDCPLKTA Pole mount kit for pole band mounting includes two brackets and two pole bands 97 FSDCPLKTB Pole mount kit for lag bolts includes extended bottom bracket 97 FSDCARKT Aerial mount kit w...