background image

LT93−PS1230−1

Issue 1 Print 3

5

 Charles Industries, Ltd. All rights reserved. Printed in the United States of America.

To AC

ground bus

(green)

WHT BLK GRN

TB1

TB2

40A/32V F

A

S

T

 ACTING

SLO−BLO

F2

Note 1

To AC hot (black)

To AC neutral bus (white)

Notes

1. AC stranded wire.

2. DC stranded wire.

3. Optional Splash Guard, part # 21-104589.

4. Internal fuse size is for 30-amp model. See Table 4 for 15- and 30-amp model fuse size.

PCB

DC

Fuse

(see Table

4 & Note 4)

AC

Fuse

(see Table

4 & Note 4)

AC power source
circuit breaker
(min. size15 amps)

F1

(PS2430 shown)

15A/250V

Access to PCB:

and

TB1 & TB2

F1, F2 & F3 Fuses

+DC

−DC

LOAD

+

Note 2

Note 3

F3

Figure 1.  C-Power 15- & 30-Amp Block Diagram

Choosing Wire Gauge

Use Table 2 and Table 3 to determine the appropriate wire gauges. Avoid unnecessarily long runs of either AC or
DC power lines.

Before working on electrical equipment, first determine there is no live power!  Double check power
connections.

DANGER

Table 2.  

Minimum Wire Size to Input of C-Power

120 VAC SHORE POWER INPUT TO C-POWER

Model Number

AC Amp Max

25’ Length

50’ Length

100’ Length

PS2415

10

16 AWG

14 AWG

10 AWG

PS2430

12

14 AWG

12 AWG

10 AWG

PS1230

10

16 AWG

14 AWG

10 AWG

220 VAC SHORE POWER INPUT TO C-POWER

PS2415

5

18 AWG

16 AWG

14 AWG

PS2430

6

16 AWG

14 AWG

12 AWG

PS1230

5

18 AWG

16 AWG

14 AWG

Summary of Contents for C-Power

Page 1: ...sue 1 Print 3 1 Charles Industries Ltd All rights reserved Printed in the United States of America C POWERR INSTALLATION INSTRUCTIONS OWNER S MANUAL 12 VDC 24 VDC 15 30 Amp MARINE ELECTRONIC POWER SUP...

Page 2: ...leaning Precaution 3 Grounding Precautions 3 INSTALLING THE C POWER 4 Choosing Mounting Hardware 4 Mounting the C Power 4 Mounting the Optional Splash Guard 4 Choosing Electrical Wiring Hardware 4 Cho...

Page 3: ...ty and operating instructions for the C Power Read the entire manual before usage Environmental Precaution Do not expose the C Power to rain snow or excessive moisture C Power Application Precaution T...

Page 4: ...one side of the mounting hardware half way into the drilled mounting holes 6 Align the mounting slots on the C Power with the secured hardware and slide the C Power s mounting flange under the washers...

Page 5: ...0V Access to PCB and TB1 TB2 F1 F2 F3 Fuses DC DC LOAD Note 2 Note 3 F3 Figure 1 C Power 15 30 Amp Block Diagram Choosing Wire Gauge Use Table 2 and Table 3 to determine the appropriate wire gauges Av...

Page 6: ...2 Route the DC wire through the right side access hole on the bottom of the C Power TB2 has one positive terminal and one negative terminal Closing the Access Door Before closing the access door make...

Page 7: ...turned on 2 Internal red LED on The unit is at half power because the ambient air is too hot The unit may be at half power because the fan is not working Full power will be restored when the temperat...

Page 8: ...re U S Metric Weight 9 pounds 4 1 kilograms Height 13 25 inches 33 7 centimeters Width 9 5 inches 24 1 centimeters Depth 3 7 inches 9 4 centimeters AC Input 120 VAC nom 220 VAC nom See the label on th...

Reviews: