background image

27

400V
32A
Type2
6-8-10-13-16-20-25-32

(from app)

50Hz/60Hz
IP55
CC 6 mA**

(from app)

No (required)
Yes, stop over 65°

Dimensions

Summary of Contents for WB132H

Page 1: ...1 English User Manual ChargeSplit DOMUS WB132H WB332H WB132P WB332P Chargesplit ...

Page 2: ...lities 1 Security Notes 2 Legal Notes 3 Safety instruction 4 Installation Instructions 5 Electrical protections device 6 Drilling and securing to wall 7 Pole installation 8 Wiring 9 Load Balancing probe 10 Introduction to charger 11 Setting up Bluetooth or WiFi Connection 12 Configuring the device in the APP 13 Controlling device from the app 14 Settings menu 15 Scheduled charging menu 16 Statisti...

Page 3: ...ided in this User Guide does not relieve the user of responsibility to follow all norms and standards or local regulations that may apply The charger device has been designed developed and manufactured to satisfy requirements safety dispositions and norms in accordance with the directives presented in the declaration of conformity This document is intended to be used as a reference guide for the i...

Page 4: ...validating warranty Do not alter or remove any warning symbols on the device such as safety symbols warning notices rating plates identification plates or cable markings INSTALLATION MUST BE CARRIED FROM PROFESSIONAL ELECTRICIANS ONLY Protect your device from any impact which it may be exposed Always respect local electricity rules and regulations as relevant Device has to be used in the operating...

Page 5: ...be tightened under ANY CIRCUMSTANCES while connected to the vehicle Safety Instructions Never use a damaged charging cable the vehicle plug or the infrastructure electrical outlet to charge Never use contacts that are dirty or wet Only connect the connector to vehicle plug and infrastructure electrical outlets that are protected against water moisture and liquids After stopping the charging proces...

Page 6: ...e device is already assembled for installation Do not open the device Charging process involves heat Select an appropriate vented area where to install the device and avoid direct sunlight Do not install the device nearby Flammable explosive or combustible materials Chemicals or solvents Flood prone areas water passage areas or humid environments Gas conductors or vapor outlets Accumulators storag...

Page 7: ...event the device will come back to normal after 60 seconds after the fault If fault is still present The power supply line must be hardwired to an existing installation and according to your local regulations The charger must be electrically protected installing externally a Miniature Circuit Breaker MCB and a Residual Circuit Breaker RCD Electrical protections device 5 MCB RCD Maximum value accor...

Page 8: ...r vertical and horizontal pole installation with matched device color Please contact us for additional details Drilling and securing to wall Pole Installation 6 7 Use included fishers and below mouonting schema attached mounting holes schema and included ...

Page 9: ...rgy management Only one option per time can be active Probe is connected to chargepoint via lower 3 5mm Jack connector SOLAR BALANCING Install the probe on Hybrid inverter AC output to catch the exceeding AC production from solar LOAD BALANCING install the probe to catch energy consumption of the house excluded charger IMPORTANT For a correct installation ONLY phases cables L1 L2 L3 must pass thro...

Page 10: ...display simply press the button By pressing front button for more than 10 second in READY state a new display language will be showed from available Italian Spanish German English France There are several charger status READY The charger is ready for charging process and the car can be connected In this state the led ring will pulse GREEN color and the display will report READY status CONNECTED Th...

Page 11: ...t fault or temperature fault in case of temperature higher than 65 C degree the charging process will be interrupted and restarted automatically when temperature lower down to 55 C degree SCHEDULE Device is in SCHEDULE status This means the charging process has been scheduled to a certain timeframe ex From 23 00 to 6 00 The display will show the SCHEDULE status and the ring will blink in GREEN WHI...

Page 12: ...onnection mode With the device totally turned OFF maintain the central button pressed Without releasing the button power up the device until the display will show CONNECT TO CHARGESPLIT WIFI and the button start flashing in RED GREEN BLUE You can now release the button A new Wi Fi network called CHARGESPLIT has been created Connect with your phone to the network and configure the connection type S...

Page 13: ...device in Bluetooth Mode After click the device will restart in this Bluetooth mode Click on Configure Wifi to configure Wi Fi connection Available Wi Fi networks will be scanned Hint if portal does not open try to remove Chargesplit from known network or try open browser after network is connected 5 6 13 ...

Page 14: ...cess Working mode will be always reported on the device screen If device is in Bluetooth mode you will see the Bluetooth symbol If in Wi Fi mode the Wi Fi signal will be reported Due to real time monitoring features of the device a stable Wi Fi connection is required in order for the device to operate correctly In case of reset of the device the credentials will be saved and the device will reconn...

Page 15: ...nder Add new Chargepoint menu After the device has been connected to Wi Fi or configured in Bluetooth mode is time to add the device in the app Configuration is automatic and based on the qrcode adhesive on side of your stations Configuring the device in the APP 12 1 15 ...

Page 16: ...loud locked to you and virtually unusable from other person This ensure that your station cannot be stolen If you need to unmate the station from the account please contact support chargepsplit com with a purchase document Click on the qr code icon and start to scan the qrcode adhesive on the side of your charging station If qrcode is valid a new window will ask you about how your charing station ...

Page 17: ...mption Solar inverter AC generation Power Ring By rotating the slider ring you can real time change the power level of the device from 8 to 32 amps A security setting under option will set the maximum selectable power for security If load balancing is active this setting is managed automatically 1 2 3 4 5 6 7 You have several options to control and real time monitor the device from menu 17 1 2 3 4...

Page 18: ...dule button See further detail explanations Settings From settings menu it is possible to control device settings See further detail explanations Statistics Wi Fi ONLY If device is connected via Wi Fi you can monitor consumption and costs from this menu See further details explanations Realtime STATUS The real time status of the device If charging is active real time delivered power and total char...

Page 19: ... configured for Wi Fi access If you change working mode and the device is not connected it will be not possible to connect again device from app To configure the device refer to configuration procedure in the manual OTA FIRMWARE If new firmware is available a popup will let you start the automatic update procedure Do not disconnect chargepoint power until firmware update has been completed Electri...

Page 20: ...nt chargepoint button more than 3 seconds You will then have 60 seconds to disconnect the car If no disconnection happen the chargepoint will return to precedent state Charge Limit This option will let you limit the total amount of kWh to be charged for a single session When active a new icon will appear in chargepoint control menu Press the icon to modify the kWh value When charging limit is reac...

Page 21: ... a specific time Scheduled charging menu 15 Select the starting time at the charge icon 1 and end time at the finish line icon 2 Be sure to select Active and click on Save To disable the schedule and come back to standard charging go in the schedule menu select Disabled and click on Save ...

Page 22: ...f consumptions and costs Statistics are divided on Week Month year base The calculated prices are based on the kWh costs in the settings menu Live house consumption statistics to last 3 hours approximately Require WiFi and LB probe installed correctly Statistics 16 22 ...

Page 23: ...alancing and if connected via Wi Fi monitor monthly consumptions and costs Chargesplit Home is V2G V2H ready with expansion slot for HPGP technology and ISO15118 stack It can also been used in professional environments with OCPP 1 6JS protocol and our OCPP SAAS solutions OCPP SAAS supports both Soap and JS protocol up to 1 6 Due to different interpretation of ocpp protocol we can guarantee 100 com...

Page 24: ... StartTransaction RemoteStartTransaction StopTransaction RemoteStopTransaction Reservation Status Notification Reboot Reservation Cancel Reservation ChangeAvailability Clear cache Reset Reserve now Send local List Unlock Connector for ocpp models R and S series refer to specific manual ...

Page 25: ...oprietary ISO15118 opt Yes Yes Internal Class 0 2 No OLED 2 42 LCD LED RING RGB BUTTON Wall Pole Opt No Yes remote Yes remote Yes Wi Fi mode required Yes 200x200x65 mm 2Kg with no cable 20 40 40 70 CE mark LVD 2014 35 EU EMCD 2014 30 EU IEC 61851 1 IEC 61851 22 IEC 62196 2 Up to 7 4kW 1P or 22kW 3P ABS UL94 V0 Charcoal Grey White Mode 3 Bluetooth Wi Fi 2 4 Ghz HPGP powerline opt 5m custom Length o...

Page 26: ... Charging configuration Locking Charging Statistics Weekly and Monthly Pause Restart Load Balancing Solar Balancing live power monitoring Maximum power settings Statistics only if connected via Wi Fi Live Monitoring Voltages Temps Amps Work with Bluetooth or Wi Fi Only one working mode at time is possible 220V 240V 1P 400v 3P 32A Type2 6 8 10 13 16 20 25 32 fromapp 50Hz 60Hz IP55 Opt Hseries CC6ma...

Page 27: ...27 Dimensions ...

Page 28: ...r caratheristic reported in this manual can vary in any moment with no notice to the user Disposal Directive 2012 19 EC At the end of its useful life the product will not be disposed of as urban waste but It must be taken to a collection center for special waste or to a distributor that provides this service Keep enviroment clean ...

Reviews: