9.0 Performance Data Sheet

Contaminant Reduction Typical RO

Influent Challenge 

Max permissible 

Minimum 

Average

Substance 

Concentration 

product water 

Percent (%) 

Percent (%)

mg/L 

concentration mg/L 

Reduction 

Reduction

Arsenic (+5) 

0.30 ± 10% 

0.010 

98.1 

99.0

Barium 

10.0 ± 10% 

2.0 

95.0 

98.8

Cadmium 

0.03 ± 10% 

0.005 

94.0 

98.3

Chromium (+6) 

0.3 ± 10% 

0.1 

95.5 

98.3

Chromium (+3) 

0.3 ± 10% 

0.1 

98.4 

99.0

Copper 

3.0 ± 10% 

1.3 

95.0 

98.4

Fluoride 

8.0 ± 10% 

1.5 

87.0 

93.8

Lead 

0.15 ± 10% 

0.010 

90.4 

96.8

Radium (226/228) 

25 pCi/L 

5 pCi/L 

80.0 

80.0

Selenium 

0.10 ± 10% 

0.05 

94.4 

97.9

TDS 

750 ± 10% 

187 

88.0 

92.2

Turbidity 

11 ± 1 NTU 

0.5 NTU 

96.4 

98.7

Model 

CWISO475PA

This system contains replaceable treatment components critical to effective reduction of TDS and efficiency of the system. Replacement 
of the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to ensure the same 
efficiency and contaminant reduction performance. Replacement parts and numbers are shown below. The product water should be tested 
periodically to verify that the system is performing satisfactorily in addition to making the parts replacement specified.

Recommended Changeout Interval

once each 3 years
once each year
once each year
once each year

RO Membrane Assembly 

75 

gpd, P/N MHA-4222  

First stage sediment filter, 5-micron, P/N TF-4113 
Second stage (5-stage only) granular activated carbon, P/N TF-4114

-CHPL

  

Second stage activated carbon block, P/N TF-4115  
Post filter, activated carbon block, P/N TF-4115  

once each year

See OWNER INSTALLATION manual for complete installation/operation and maintenance requirements, 

including manufacturer’s limited warranty.

This system 

can typically treat

 water containing pentavalent arsenic (also know as As(V), As(+5), or arsenate) at concentrations 

of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to 

be used on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated 

to contain only pentavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete 

conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet 

for further information

Conforms to NSF/ANSI 58 for pentavalent arsenic reduction. See 9.1 arsenic facts section for an explanation of reduction performance. 

Testing performed under under standard laboratory conditions. Actual performance may vary.

Specifications

Pentair membrane 75

 gallon per day reverse osmosis membrane

Storage tank: 4.0 gallon total volume; 2.2 gallon water volume
Dimensions: 14in. long by 6in. wide by 15.5in. high: Tank: 11in. dia by 15 1/2in. high            Weight: 24 pounds

Conditions of Use

Do not use with water this is microbiologically unsafe, or of unknown quality, without adequate disinfection before or 
after the system.
Pressure: Minimum-40psig: Maximum-100psig
Temperature: 40 to 100°F
pH Range = 3.0 to 10, max iron content - 0.3ppm
Turbidity of inlet water-less than 1.0 NTU, maximum TDS-1500ppm

-CHPL

-CHPL

-CHPL

MP-4235

Summary of Contents for HydroSplash CWISO475CHPL

Page 1: ...HydroSplash Reverse Osmosis Undersink Water Filtration System Owners Installation Manual Model CWISO475PA NF CHPL...

Page 2: ...The Charger HydroSplash RO system is made with quality components to provide cleaner safer drinking water No chemicals are added or used in this system...

Page 3: ...Iron Sinks pg 6 2 7 Install Faucet pg 7 2 8 Tubing Connections pg 8 2 9 Air Gap Faucet Installation pg 10 3 0 System Start Up pg 11 3 1 Air Purge pg 11 3 2 Start Up pg 11 4 0 Recommended Filter Change...

Page 4: ...ls and skills Be cautioned that an extra faucet for purified water will be installed This requires a 7 8 inch diameter hole in the sink top If there is not an extra hole existing a new one must be dri...

Page 5: ...cooking Chemical contaminants such as mercury lead and others not yet identified that seep into municipal water systems are removed The water pressure forces the water molecules through the Reverse Os...

Page 6: ...age tank For best performance the tank should be located as close to the clean water faucet supplied as possible within 20 feet Mounting the RO filter unit under a sink Fig 1 Mount the unit to the wal...

Page 7: ...NE IN OUT Regular Faucet UPC Approved Drain Connection Not included Slip Joint AdapterI nstall Ball Valve Drain Line 1 4 black tubing Tap Water Feed Line to Pre Filter 1 4 orange tubing Post Filter Ca...

Page 8: ...ect the cold water riser tube flex line from the valve Install the slip joint connector with the black washer Loosen the nut and separate the cold riser tube from the faucet shank Gently bend the rise...

Page 9: ...e sink below where the faucet will be mounted must be clear of any obstructions Some conditions may eliminate the need to drill a hole in the sink such as a faucet previously installed in the sink a h...

Page 10: ...otor speed may be gradually increased The cut may require three to four minutes to complete Going faster could result in excessive chipping Be sure a complete ring has been cut through the porcelain t...

Page 11: ...he sink hole From below the sink assemble the mounting hardware Use a deep socket to tighten the nut Figure 6 Escutcheon Plate Small Rubber Washer Counter Top Lock Washer Faucet Adapter 3 8 Tubing whi...

Page 12: ...n the HydroSplash are of Quick Connect O ring seal design and manufacture Use the tubing and follow the instructions in Figure 8 to make the connections If you cut the tubing make sure it is a square...

Page 13: ...e faucet adapter on to the end of the faucet Find the white colored 3 8 tubing and insert into the quick connect fitting as described in Section 2 8a Connect the end of the tube to the quick connect f...

Page 14: ...ack colored 1 4 drain line from the membrane Connect this tube to the 1 4 barbed fitting on the air gap faucet Find the 3 8 black tubing in the parts kit Connect this tube to the 3 8 barbed fitting on...

Page 15: ...en the product water faucet and let the water flow until all the air has been expelled from the system This will take about 30 minutes Close the product water faucet Now open the tank valve Let the sy...

Page 16: ...ent Frequency 6 12 Months 6 12 Months 3 5 Years 6 12 Months These filter replacement elements are available from your dealer When you buy or install your Charger HydroSplash we recommend that you buy...

Page 17: ...0 Conditions Of Use Water must be microbiologically safe System pressure 40 to 100 PSIG Temperature 40 to 100 F pH range 3 to 10 Maximum TDS 1500 PPM Maximum Iron FE 0 3ppm Maximum Manganese Mn 0 1pp...

Page 18: ...purchaser of the product from a Charger dealer for use by the purchaser Any modifications of the product shall render the warranty invalid and Charger will have no further responsibility All warranty...

Page 19: ...operation and maintenance requirements including manufacturer s limited warranty This system can typically treat water containing pentavalent arsenic also know as As V As 5 or arsenate at concentrati...

Page 20: ...rsenic from water very well RO systems are very effective at removing pentavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment c...

Page 21: ...on its surface This is a chemical mechanical process unique to carbon that has been activated made to have high surface area The second reason is that the carbon block also takes out VOCs volatile or...

Page 22: ...of water when the tank is full an auto control valve is used in the system as shown in Figure A 1 The pressure in the tank is set nominally to be 2 3 of the incoming line pressure When this ratio is r...

Page 23: ...19...

Page 24: ...Charger Water Treatment Products 8150 N Lehigh Ave Morton Grove IL 60053 chargerwater com...

Reviews: