background image

 

 

 

 

© 2021 Charge Amps AB 

Installation manual for  
Charge Amps  
Aura Dual Pole Mount 
Doc. Nr: 130129 

Rev 01 
 

Address: 

Charge Amps AB 
Frösundaleden 2B 
SE-169 75 Solna 
Sweden 

Contact: 

+46 (0)8 55 11 2000 
[email protected] 
www.chargeamps.com 

Org. No. 556897-7192 

Registered office: Solna 
 

 

19 

 

Warranty conditions 

Check the warranty conditions on our website: https://cms.charge-amps.com/wp-
content/uploads/2020/11/warranty_policy-1.pdf 

Safety precaution 

To be able to install and mount the Aura, you have to be a licensed electrician and follow 
all safety precautions to ensure a safe and correct installation. Installation should follow 
according to the User Agreement and the instructions in this document. 

Mechanical information 

 

Weight: 3 kg 

 

Product dimension: Height 380 mm, width 133 mm, depth 137 mm 

 

Product material: Stainless steel 

 

IP 44 when installed properly 

Product recycling 

Recycling is part of any products lifecycle. Aura Dual Pole Mount contains stainless steel 
and should be recycled accordingly. 

Rights 

The information in this document has been checked for accuracy. Charge Amps AB 
reserves the right to make technical changes and changes to the contents of the 
document without prior notice. Charge Amps AB can not guarantee that all of the content 
of this particular document is accurate, up-to-date, and free from printing and 
proofreading errors. Moreover, Charge Amps AB cannot be held liable for any mistakes, 
near-misses, injuries/damage or incidents – direct or indirect – that can be linked to the 
use of the safety precautions or products in this document.  
Charge Amps AB reserves all rights to this document, as well as the information and 
illustrations therein. It is strictly forbidden to – in whole or in part – copy, adapt or 
translate the information without prior written permission from Charge Amps AB. 
© Copyright 2021, Charge Amps AB. All rights reserved.  

Summary of Contents for Aura Pole Mount

Page 1: ...Charge Amps Aura Dual Pole Mount Installation manual...

Page 2: ...ps com www chargeamps com Org No 556897 7192 Registered office Solna 2 Table of Contents User Agreement 3 Greetings installer 4 About Aura Dual Pole Mount 5 Contents of the package 5 Provided by the i...

Page 3: ...cannot be used without two Charge Amps Auras installed properly The Aura Dual Pole Mount and the two Charge Amps Auras should be regarded as one assembly The power should be switched off during the co...

Page 4: ...7192 Registered office Solna 4 Greetings installer This installation manual is intended for qualified Aura Pole Mount installers and describes how to install the product safely and properly Installati...

Page 5: ...cs of M6 bolts 4 pcs of M6 nuts 8 pcs M6 washers 5 pcs M4 screws 1 tooth washer M4 and 6 pcs of M6 pin stop screws NOTE The four M6 x 20 mm screws included in the Aura product kit will be used for mou...

Page 6: ...t 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 6 Model view Aura Dual Pole Mount 1 Aura Dual Pole Mount 2 Din Rail 3 Lid 4 1 pcs EPDM Gasket 5 4...

Page 7: ...ng on the preferred height of the charger the 60 mm pole might have to be cut That power is shut off during the whole installation Step 1 The terminal block or any other preferred electronic component...

Page 8: ...den 2B SE 169 75 Solna Sweden Contact 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 8 Step 3 Slide the O ring onto the pole Then slide the pole m...

Page 9: ...1 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 9 Step 4 Tighten the 6 pcs of M6 pin stop screws which fixates the pole mount onto the pole Use the hex key M6...

Page 10: ...info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 10 Step 5 1 Unscrew the two M6 x 20 screws from the bottom of the Aura and remove the bracket highlighted in blue in...

Page 11: ...chargeamps com Org No 556897 7192 Registered office Solna 11 Attach the two M6 x 20 screws so that it connects the pole mount and the Aura The screws should just temporarily fixate the Aura they shoul...

Page 12: ...s AB Fr sundaleden 2B SE 169 75 Solna Sweden Contact 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 12 Step 7 1 Slide the next Aura unit to the po...

Page 13: ...1 Address Charge Amps AB Fr sundaleden 2B SE 169 75 Solna Sweden Contact 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 13 Side Front view 3 Tight...

Page 14: ...the front Depending on the installation type Option1 1 If you got two incoming power cables pull them through the pole mount 2 Close the lid make sure that no cable or obstacle is in contact with the...

Page 15: ...tact 46 0 8 55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 15 2 Connect the earthing circuit to the earthing screw M4 tooth washer 3 Cut new appropriate...

Page 16: ...e the lid make sure that no cable or obstacle is in contact with the lid If a cable push on the lid the IP 44 protection will fail Option 3 1 If you got one incoming power cable and one outgoing read...

Page 17: ...geamps com Org No 556897 7192 Registered office Solna 17 2 Cut new appropriate cables connect them to upper side of the terminal block and pull them through the bottom of the Aura Connect the first se...

Page 18: ...55 11 2000 info charge amps com www chargeamps com Org No 556897 7192 Registered office Solna 18 4 Close the lid make sure that no cable or obstacle is in contact with the lid If a cable push on the...

Page 19: ...en installed properly Product recycling Recycling is part of any products lifecycle Aura Dual Pole Mount contains stainless steel and should be recycled accordingly Rights The information in this docu...

Reviews: