![Char-Broil Front Avenue Use And Care Manual Download Page 5](http://html1.mh-extra.com/html/char-broil/front-avenue/front-avenue_use-and-care-manual_2590858005.webp)
5
Nipple has to be
centered into the
LP tank valve
5. Hold regulator, insert nipple (B) into LP tank valve.
Hand tighten coupling nut, holding regulator in a
straight line (C) with LP tank valve so as not to cross
thread the connection.
6. Turn the coupling nut clockwise to tighten to a full solid stop.
The regulator will seal on the back-check feature in LP tank
valve, resulting in some resistance. An additional one-half
to three quarters turn is required to complete
connection. Tighten by hand only - do not use tools.
NOTE: If you cannot complete connection, disconnect regulator and
repeat steps 5 and 6. If you are still unable to complete the
connection, do not use this regulator!
Hold coupling nut
and regulator as
shown for proper
connection to LP
tank valve.
• Do not insert any foreign objects into the valve
outlet. You may damage the valve and cause a leak.
Leaking propane may result in explosion, fire, severe
personal injury, or death.
• Never attempt to attach this grill to the self-contained
LP gas system of a camper trailer or motor home.
• Do not use grill until leak checked.
• If leak is detected at any time, STOP and call the Fire
Department.
• If you cannot stop a gas leak, immediately close LP
tank valve and call LP gas supplier or your fire
department!
B
B
B
B
B
C
C
C
C
C
• A disconnected LP tank in storage or being transported must
have a safety cap installed (as shown). Do not store an LP
tank in enclosed spaces such as a carport, garage, porch,
covered patio or other building. Never leave a LP tank inside a
vehicle which may become overheated by the sun.
• Do not store LP tank in an area where children play.
Leak Testing Valves, Hoses and Regulator
1. Turn all grill control knobs to OFF.
2. Be sure regulator is tightly connected to LP tank.
3. Completely open LP tank valve by turning hand wheel counter
clockwise. If you hear a rushing sound, turn gas off
immediately. There is a major leak at the connection. Correct
before proceeding.
LP Tank Removal, Transport And Storage
• Turn OFF all control knobs and LP tank valve. Turn coupling nut
counter clockwise by hand only - do not use tools to disconnect. Lift
LP tank wire upward off of LP tank collar, lift LP tank up and off of
support bracket. Install safety cap onto LP tank valve. Always use
cap and strap supplied with valve. Failure to use safety cap as
directed may result in serious personal injury and/or
property damage.
LP Tank
Valve
Safety
Cap
Retainer
Strap
• NEVER store a spare LP tank under or near grill or in
enclosed areas.
• Never fill the cylinder beyond 80% full. An overfilled
spare LP tank is hazardous due to possible gas
released from the safety relief valve. The safety relief
valve on a LP tank could activate releasing gas and
cause a fire, resulting in serious injury, property
damade or death.
• If you see, smell or hear escaping gas, immediately
get away from the LP tank/grill and call your fire
department.
• All spare LP tanks must have safety caps installed on
the LP tank outlet.