Hardware Setup
Remote Bypass:
In some cases, it may be necessary to control the door from a remote area such
as a security station or reception desk. The SIK Series Keypad provides for a
Remote By-Pass (Exit Switch) or Keypad override. This can be accomplished by
connecting a normally open switch from the VIOLET Remote Bypass wire to the
BLACK wire. When the Remote By-Pass switch is depressed, the contact
bypasses the Keypad and activates the relay for the same time length as the
programmed Door Open Time (See Programming Door Open Time . Page 9).
Anti-Tailgating:
Some security applications require stricter door monitoring. Anti-tailgating can be
controlled by installing a normally closed door monitor switch to the BROWN
Door Monitor wire and the BLACK wire on the wire harness. This switch may be
the output of a latch monitor switch, a monitor maglock or an alarm switch that
senses door movement. When this switch opens, it relocks the door immediately.
IMPORTANT:
If you wish to use door monitor switch, you must also cut the
BROWN Door Monitor wire loop on the back of the Keypad.
Keypad Illumination:
Designed for areas will low ambient lighting, the SKE-6L I provides nighttime
illumination. Keypad illumination is ON by default. This option can be turned OFF
by cutting the BLUE Illumwire loop on the back of the Keypad.
Setting Output Options:
The SIK Series Keypad provides options for configuring the relay output as well
as the .A grounding outputs. These options include Voltage vs. Dry Contact
Output and Latching Authorization for the main output.
Remote Bypass:
In some cases, it may be necessary to control the door from a remote area such
as a security station or reception desk. The SIK Series Keypad provides for a
Remote By-Pass (Exit Switch) or Keypad override. This can be accomplished by
connecting a normally open switch from the VIOLET Remote Bypass wire to the
BLACK wire. When the Remote By-Pass switch is depressed, the contact
bypasses the Keypad and activates the relay for the same time length as the
programmed Door Open Time.
Anti-Tailgating:
Some security applications require stricter door monitoring. Anti-tailgating can be
controlled by installing a normally closed door monitor switch to the BROWN
Door Monitor wire and the BLACK wire on the wire harness. This switch may be
the output of a latch monitor switch, a monitor maglock or an alarm switch that
senses door movement. When this switch opens, it relocks the door immediately.
IMPORTANT:
If you wish to use door monitor switch, you must also cut the
BROWN Door Monitor wire loop on the back of the Keypad.
10
11
1 / 2
2 / 3
4 / 5
6 / 7
9 / 0
Integrating the ST-C5IDS
ST-C5ID
(Sold Separately)
(Rear View)
S G P
P-0930
PRO
C
H A N N E L
T M
V
I S I O N
Model
P-0930
Whole-House Intercom
Page Out
Page Trigger
IR
Emitters
+15VDC
Power
Link
In
Link
Out
Hub
A
B
C
D
Room 1
Room 2
Room 3
Room 4
Room 5
Room 6
Press and hold
door station number
to activate ST-C5IDS
ST-3000
Connect the orange and green wires from the back of the SIK Keypad
into the strike terminals on the ST-C5IDS. The negative wire (cut in two)
of the power supply of the strike should also be applied to the strike
terminal on the ST-C5IDS. To open the door, press and hold the room
button on the ST-3000, or enter the code on the SIK Keypad.
For systems using the P-0930
Strike
Power
Supply
Door strike
Mechanism
(NOT SOLD BY CHANNEL VISION)
Positive
+
N.O. (Orange)
Negative
-
Negative
-
Ground (Green)