background image

Description

 

Channel Vision’s 15dB power injected inline amplifier provides the lowest induced noise figure available and is designed with the 
future in mind. Unlike other RF amplifiers, the CVT-15PIA features a bi-directional return path for use with future interactive TV, 
addressable cable box converters, and ultra high-speed cable modems. 
 
 
 

Instructions

 

Step 1:

 Mount amplifier. 

Step 2: 

Connect cable or antenna signal to the INPUT jack. 

Step 3:

 Connect OUTPUT jack to distribute signal to all the TV’s in the house. 

Step 4:

 Connect power to 12VDC input, or use PIA (power injector) for remote  

             power capability.  

Note

: must use DC passive splitters. 

 

Please Note:

 

The unused trunk line connector of the last outlet device in each trunk line  
MUST BE TERMINATED using a 75

 terminator 

(model 2101).

 

12VDC IN                    RF INPUT

Channel Vision

MULTI-ROOM AUDIO VIDEO TECHNOLOGY

CVT-15PIA

5-42MHz RETURN PATH PASS
54-1000MHz FORWARD PATH

3dB LOW NOISE AMPLIFIER

15dB GAIN

                   OUT-PWR

Cable or
Antenna

12VDC IN                    RF INPUT

Channel Vision

MULTI-ROOM AUDIO VIDEO TECHNOLOGY

CVT-15PIA

5-42MHz RETURN PATH PASS

54-1000MHz FORWARD PATH

3dB LOW NOISE AMPLIFIER

15dB GAIN

                   OUT-PWR

Cable or
Antenna

HS-3

CVT-PI

880

DC Blocker

Standard Wiring Layout 

Layout with Power Injector 

Specifications

 

Parameter

                             

Condition

             

Min

           

Typ

         

Max 

Gain

                                        f=54MHz               13.5           14.5         15.5 

                                                f=1000MHz            14.0           15.5         17.0 

Flatness

                                   54-1000MHz             -              +/-0.8          - 

Insertion Loss

                        5-40MHz                -1.5               -            -0.5 

Return Loss IN 

                     5-40MHz                   -              -18           -14 

                                                54-750MHz               -              -20           -16 
                                                750-1000MHz           -              -16           -14 

Return loss OUT

                    5-40MHz                   -              -18           -14 

                                                54-750MHz               -              -20           -16 
                                                750-1000MHz           -              -16           -14 

Tap - Tap Isolation

                54-1000MHz             -                 -               - 

2nd Order Input Intercept

            -                       80                -               -

 

3rd order input intercept

              -                       60                -               - 

Composite Second Order

              -                         -                 -            -60 

Composite Triple Beat

                  -                         -              -70           -60 

Noise Figure

                           54-60MHz                 -                3            3.5 

                                                60-750MHz               -              2.4           3.0 
                                                750-1000MHz           -                3            4.0 

Hum Modulation

                           -                         -                -             -70 

Return Path Level

                 5-27MHz                   -                -             60 

                                                27-40MHz                 -                -             40 

RFI Isolation

                          5-1000MHz               -                -             -130 

DC Current

                                    -                       70             110          170 

Warning

 

To prevent fire or shock hazard, 

do not expose this appliance to 

rain or moisture. 

© 2002, 

C

HANNEL

 V

ISION

™ 

Reviews: