Chandler PRO3 Top Mount PTN Technical Manual Download Page 4

new eC MoToRs foR PRo

3

 PaCkaGed RefRiGeRaTion sysTeMs

Introducing the most-energy efficient motor available for packaged refrigeration systems.

  

Choosing energy-

efficient motors for your packaged systems can provide significant energy savings and lower operational costs.  

Additionally, because these motors can help reduce heat load (and system run-time), they can improve the 

reliability and longevity of refrigeration equipment.

Electronically commutated (Ec) motors

 even further improve energy efficiency and equipment reliability.  EC 

motors by InterLink™ are up to 75% efficient – that’s a 51-59% increase over shaded pole motors and a 30-35% 

increase over PSC motors.  As with PSC motors, you save money both directly from a decrease in motor watts and 

also from a reduction of heat gain into the refrigerated space.  

Permanent split capacitor (Psc) motors

 can significantly lower your energy costs.  PSC motors average 30-35% 

higher efficiency than shaded pole motors and offer dual energy savings by reducing motor watts and heat gain 

into the refrigerated space.

 Savings are calculated using a cost of $.09/kWh

* T For Outdoor, N for Indoor.  

   

Energy savings (annual)

Model

Ec vs  

shaded Pole Motors

Ec vs Psc Motors

Psc vs  

shaded Pole Motors

H

igh 

Temper

atur

e Units

P*N024H2

$42

$13

$29

P*N029H2

$42

$13

$29

P*N040H2

$42

$13

$29

P*N047H2

$71

$23 - $32

$39 - $48

P*N063H2

$131

$65

$66

P*N072H2

$131

$65

$66

P*N099H2

$202

$97

$105

P*N128H2

$202

$97

$105

Lo

Temper

atur

e Units

P*N019L6

$40

$13

$27

P*N021L6

$67

$18 - 30

$37 - $46

P*N031L6

$123

$60

$63

P*N044L6

$123

$60

$63

P*N052L6

$190

$91

$99

P*N069L6

$190

$91

$99

Summary of Contents for PRO3 Top Mount PTN

Page 1: ...CH PTMTB January 2008 Replaces CH PROTB 08 07 PRO3 TOP MOUNT Packaged Refrigeration System Technical Guide Model PTN and PTT For Indoor and Outdoor Applications...

Page 2: ...2 B H PRODUCT LINE DESIGN ORIENTATION APPLICATION LOCATION NOMINAL CAPACITY TEMPERATURE RANGE REFRIGERANT TYPE VOLTAGE MOTOR PRO3 Packaged Refrigeration System T Top Mount N T Indoor Outdoor BTUH x 1...

Page 3: ...rol Maximizes storage area in a cooler or freezer evaporator grill mounts flush on a standard 4 or a recessed 5 1 2 ceiling panel Ease of Use System is factory assembled evacuated charged run tested a...

Page 4: ...C motors you save money both directly from a decrease in motor watts and also from a reduction of heat gain into the refrigerated space Permanent Split Capacitor PSC motors can significantly lower you...

Page 5: ...30 17 2 825 No C 290 132 PT 128H2C 208 230 3 60 14 8 20 12 8 825 No C 285 129 PTN019L6A 115 1 60 13 0 20 13 0 340 Yes 5 20R A 101 46 PT 021L6A 115 1 60 14 5 20 12 3 350 Yes 5 20R B 213 97 PT 021L6B 20...

Page 6: ...sions Figure A Small Cabinet Design indoor only Figure B Medium Cabinet Design Figure C Large Cabinet Design 23 5 59 69 cm on outdoor models with weatherhood 21 5 54 61 cm on outdoor models with weath...

Page 7: ...p Control Cooler 115V 28916301 1 1 1 1 Freezer Sensor 28912101 2 2 2 2 2 2 2 2 Cooler Sensor Coil 28916202 1 1 1 1 1 1 1 1 1 1 1 Cooler Sensor Room 28916203 1 1 1 1 1 1 1 1 1 1 1 Heater Limit Thermost...

Page 8: ...1881 FAX 770 465 5990 www chandlerref com Since product improvement is a continuing effort we reserve the right to make changes in specifications without notice CH PTMTB 0108 version 000 For more info...