background image

 

35 

 

2D Symbologies

 

Symbologies

 

Readable

Default

 

Enable

 

Data

 

Matrix

 

PDF417

 

 

MicroPDF417

 

MaxiCode

 

QR

 

code

 

Aztec

 

 

EAN.UCC

 

composite

 

 

 

 

D. Technical Specifications 

D-1 Physical Characteristics 

Weight

  

Scanner

 

Accessory

 

KBW

 

cable

 

RS232

 

Cable

 

USB

 

Cable

 

AC

 

adaptor

 

Approx.

 

135g

 

 

Approx.

 

75g

 

Approx.

 

123g

 

 

Approx.

 

67g

 

 

Approx.

 

125g

  

Material

 

ABS

 

Plastic

 

Connector

 

RJ

 

45C

 

10Pins

 

Cable

 

Length

 

5Ft.

 

(150mm)

 

Dimension

 

Scanner

 

193x90x72mm

 

 

D-2 Performance Scanner Characteristics 

Light

 

source

Visible

 

Red

 

light

 

650nm

 

±

 

10nm

 

Scan

 

rate

  

200scans/sec

 

auto

 

adaptive

 

in

 

linear

 

mode

 

56

 

images/sec

 

auto

 

adaptive

 

in

 

area

 

mode

 

Optical

 

resolution

 

752

 

Horizontal

 

x

 

480

 

Vertical

 

pixels,

 

256

 

gray

 

levels

 

Scan

 

angle

 

Horizontal

 

70°±10%

 

(Forward:

 

20

°

/

 

Backward:

 

50

°

)

 

Vertical

  

80°±10%

  

(Left

 

40°/

 

Right

 

40°)

 

 

Interface

   

IG

300

 

 

 

RS232,

 

USB

 

(HID

 

KBW

 

and

 

Virtual

 

COM

 

Port)

 

 

Summary of Contents for IG-300

Page 1: ...IG 300 2D Imager Barcode Scanner User s Manual...

Page 2: ...ty Tool 7 4 4 Factory Default Settings 7 5 Operating Settings 8 5 1 Scanning Triggering 8 5 2 Time Out 10 5 3 Good Read Mode 10 5 4 Buzzer Beep Tone 10 5 5 Good Read Duration 12 5 6 Bad Read Message S...

Page 3: ...is user manual for reference sometime 3 Before cleaning the device the users must cut off all AC power Do not use liquid or spray type of detersive to clean the device Please use dampish cotton cloth...

Page 4: ...abnormally 18 Don t storage the device at the temperature lower than 20 C 4 F or higher than 70 C 158 F to avoid any damage 1 2 FCC Warning This equipment complies with the requirements in Part 15 of...

Page 5: ...mager barcode scanning and picture capture This device is very easy to configure by this manual you can set up by scanning all necessary programming codes one time that meet applications the settings...

Page 6: ...amaged immediately contact your dealer ATTENTION Store the packing material and boxes it should be used whenever the device is transported for servicing 3 2 Mounting Once you have unpacked all compone...

Page 7: ...te correctly between the device and your system 3 4 Switching Cable Before removing the cable from the scanner it s recommended to turn off the power of the host system and the power supply has been d...

Page 8: ...ack to the factory default settings just scans the programming code factory default In order to change the scanner settings please follow the sequence below 1 Power up the scanner 2 Change scanner set...

Page 9: ...In this case you can setup your scanner by using the advanced Utility Tool This tool can be used with the following operation systems Windows98 Windows2000 Windows XP en Windows Vista This Utility To...

Page 10: ...until a period of inactivity lasting the time specified by the timeout After the timeout the scan engine turns off Flashing Flashing mode allows power up the lighting and decoding are on no need to ac...

Page 11: ...mode after a period of inactivity lasting the time specified by the trigger timeout the scanner switches back to flashing mode Toggle This mode allows lighting and decoding toggle when the trigger li...

Page 12: ...Mode When active the scan engine stops the reading session after a successful decoding Note This parameter is NOT used with continuous and continuous flashing modes Active Not Active 5 4 Buzzer Beep T...

Page 13: ...5 4 2 Good Read Beeps One Beep Two Beeps None 5 4 3 Beep Duration 60 msec 80 msec 200 msec Off 5 4 4 Timing During Transmission Before Transmission After Transmission 11...

Page 14: ...5 5 Good Read Duration 5 5 1 Good Read Led Duration 80 msec 0 5 sec 1 sec Off 5 5 2 Error Beep On Off 5 5 3 Setup Beep On Off 12...

Page 15: ...5 6 Bad Read Message Settings Default NOREAD Active Not Active 13...

Page 16: ...rcodes Area mode allows you to set the position of the VEGA in any direction regardless of the orientation of the barcode and perform a good read on 1D and 2D barcodes Linear mode allows you to increa...

Page 17: ...6 2 Firmware Version Display the firmware version of the scanner please scan below barcode Engine Firmware Version Scanner Decoder Firmware Version 15...

Page 18: ...s To set the scanner parameters to factory default Set factory default Reset all configuration parameters to their factory default setting After this reset you must select all required parameters that...

Page 19: ...7 2 RS232 Parameters Baud Rate 1200 2400 4800 9600 19200 38400 7 2 1 Data Bits Data Bits 7 Data Bits 8 7 2 2 Stop Bits Stop Bits 1 Stop Bits 2 17...

Page 20: ...7 2 3 Parity None Even Odd Mark Space 7 2 4 Handshaking RTS CTS Enable RTS CTS Disable ACK NAK Enable ACK NAK Disable XON XOFF Enable XON XOFF Disable 18...

Page 21: ...7 2 5 Keyboard Wedge Mode Parameter 1 Terminal Type IBM PC AT PS 2 IBM PC XT IBM PS 2 25 30 2 Capslock Detection Enable Disable 3 Upper Lower Case No change Upper Case Lower Case 19...

Page 22: ...4 Send Character by ALT Method Enable Disable 5 Select Numerical Pad ON OFF 6 Time out Between Characters 0 ms 5 ms 10 ms 25 ms 50ms 100ms 20...

Page 23: ...7 Language Selection US English UK English Italian Spanish French German Swedish Switzerland Hungarian Japanese 21...

Page 24: ...Belgium Portuguese Denmark Netherlands Turkey Reserved 1 22...

Page 25: ...7 3 Decoding Selection 7 3 1 Symbologies Selection Australian Post ON Australian Post OFF AZTEC ON AZTEC OFF BPO ON BPO OFF Canada Post ON Canada Post OFF CODABAR ON CODABAR OFF Codablock A ON 23...

Page 26: ...Codablock A OFF Codablock F ON Codablock F OFF CODE 11 ON CODE 11 OFF CODE 39 ON CODE 39 OFF CODE 93 ON CODE 93 OFF CODE 128 ON CODE 128 OFF GS1 128 ON 24...

Page 27: ...GS1 128 OFF DATAMATRIX ON DATAMATRIX OFF DATAMATRIX MIRROR ON DATAMATRIX MIRROR OFF Dutch Post ON Dutch Post OFF EAN 8 ON EAN 8 OFF EAN 13 ON EAN 13 OFF 25...

Page 28: ...128 ON EAN 128 OFF GS1 CC A B ON GS1 CC A B OFF GS1 CC C ON GS1 CC C OFF GS1 DataBar Omni ON GS1 DataBar Omni OFF GS1 DataBar Limited ON GS1 DataBar Limited OFF GS1 DataBar Expanded ON GS1 DataBar Ex...

Page 29: ...Infomail ON Infomail OFF Interleaved 2 of 5 ON Interleaved 2 of 5 OFF Japan Post ON Japan Post OFF Matrix 2 of 5 ON Matrix 2 of 5 OFF MaxiCode ON MaxiCode OFF MicroPDF417 ON MicroPDF417 OFF 27...

Page 30: ...MSI ON MSI OFF PDF417 ON PDF417 OFF Planet ON Planet OFF PLESSEY ON PLESSEY OFF Postnet ON Postnet OFF QR Code ON QR Code OFF 28...

Page 31: ...Standard 2 of 5 ON Standard 2 of 5 OFF Sweden Post ON Sweden Post OFF Telepen ON Telepen OFF TLC 39 ON TLC 39 OFF UPC A ON UPC A OFF UPC E ON UPC E OFF 29...

Page 32: ...scanner to read a series of bar codes and then transmit them all at once Not active Active Active exclusive Number of bar codes compose 2 Number of bar codes compose 3 Number of bar codes compose 4 N...

Page 33: ...data according to the following format BAR CODE DATA POSTAMBLE STRING Example To send a ETX after the Barcode scan only programming code ETX As a result the scanner will give the following barcode da...

Page 34: ...Appendixes A Decimal Value Table 0 1 2 3 4 5 6 7 8 9 32...

Page 35: ...B ASCII Table 33 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z...

Page 36: ...8 ISBN ISBT Code 11 Code 39 Code 93 93i Code 128 Interleaved 2 of 5 Matrix 2 of 5 Instustrial 2 of 5 Standard 2 of 5 Codabar MSI Plessey Telepen BPO Codablock Informail Planet TLC 39 Postnet Postal co...

Page 37: ...Approx 125g Material ABS Plastic Connector RJ 45C 10Pins Cable Length 5Ft 150mm Dimension Scanner 193x90x72mm D 2 Performance Scanner Characteristics Light source Visible Red light 650nm 10nm Scan rat...

Page 38: ...peration Voltage 5 VDC 5 Current Operating 450 mA max 5 VDC Current Standby 37 mA typical 5 VDC AC transformers 5 2 VDC 650 mA Input AC 100 240V D 5 Environmental Operating Temp 0 C to 50 C Storage Te...

Page 39: ...9 0 125 mm 5 2 cm 12 1 cm 0 20mm 2 0 cm 21 5 cm 0 25mm 2 4 cm 26 cm 0 5mm 4 cm 44 cm 1mm 7 cm 82 cm UPC EAN 0 33 mm 4 cm 31 cm Data matrix 0 191 mm 5 3 cm 16 2 cm 0 254 mm 3 8 cm 21 cm 0 381 mm 28 cm...

Page 40: ...Symbologies Scan one or more of these barcodes to test barcode symbologies you enabled Codabar Code 39 Code 93 Code 128 DataMatrix EAN 8 1234 5670 EAN13 1 234567 890128 EAN 128 Interleaved 2 of 5 MSI...

Page 41: ...39 PDF417 GS1 DataBar Omnidirectional GS1 DataBar Omni Stacked GS1 DataBar Expanded GS1DataBar Expanded Stacked GS1 DataBar Limited UPC A 0 12345 67890 5 UPC E 0 123456 5...

Page 42: ......

Page 43: ...ult Engine Firmware Version Scanner Decoder Firmware Version Due to Champtek s Scantech ID s continuing product improvement programs specifications and features are subject to change without notice 01...