background image

Champion Cooler 

5800 Murray St.

Little Rock, AR 72209

www.championcooler.com

Portable Evaporative Cooler

Safety Rules

1.  Unit must be in the Off Position and Unplugged from power receptacle when performing any mainte-

nance.

2.  To reduce the risk of electric shock, plug unit into a properly grounded 120 Volt A.C., 60 Hz receptacle.
3.  To reduce the risk of electric shock, install only on a circuit protected with a Ground Fault Circuit Inter-

rupter (GFCI).

4.  This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety.  Children should be 
supervised to ensure that they do not play with the appliance.

 

WARNING:  To reduce the risk of fi re or electric shock, do not use this fan with any “solid-state 

fan speed control device.”

110489-5
5/09

Evaporative Cooling

Evaporative cooling is an economical way to cool.  Air is cooled  while being drawn across wet evapora-
tive media.  The movement of this fresh cooled air over the skin is what makes it feel cool.  It is important 
when using an evaporative cooler in an enclosed space to have adequate exhaust by opening windows, 
doors, etc.  Without an outlet to exhaust the air, humidity will build up in the enclosed space and the 
unit will not cool adequately.  It is preferable to have an opening behind the unit to bring in fresh air and 
another opening across the room to exhaust and help move the air.

Read And Save These Instructions

NOTICE:  This Product May Temporarily Produce An Odd Odor When First 
Turned On.  This Is NORMAL And Will Dissipate After A Few Hours.  

If you have any problems with this product, please call 1-800-643-8341 
BEFORE returning it to your retailer.

Model

CP70

Summary of Contents for UltraCOOL CP70

Page 1: ...nce WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device 110489 5 5 09 Evaporative Cooling Evaporative cooling is an economical way to cool Air is cooled while being drawn across wet evapora tive media The movement of this fresh cooled air over the skin is what makes it feel cool It is important when using an evaporative cooler in a...

Page 2: ... minutes after the last button on the control is pushed Pump Cooler Operation To operate this unit as an evaporative cooler the unit must be filled with water and the pump powered on Press the Pump button to turn on the pump The water drop indicator on the display will flash while the pump is on To operate the unit as a fan only press Pump to turn off the pump Note The pump will not run if the wat...

Page 3: ...ser only Register your product online at www championcooler com eac onlineregistration eac htm Maintenance WARNING Before doing any maintenance be sure unit is unplugged Drain Unit To drain the unit remove the media frame and remove the rubber drain stopper from the bottom of the unit by pulling it out of the drain hole The unit should be drained periodically to keep the water fresh We recommend d...

Page 4: ...d Replacement Parts No Description CP70 1 Evaporative Media 110132 3 2 Evaporative Media Frame Assembly 110874 1 3 Water Tray 110874 3 4 Water Distributor Nozzle 110874 4 5 Keepers Set of 4 110871 6 Pump 110439 1 7 Drain Plug 110698 8 Float Assembly 110873 9 Swivel Casters Non Locking 110822 6 10 Swivel Casters Locking 110822 7 11 Pedestal 110874 2 12 Water Distributor Tubing 110734 1 13 M4 x 12mm...

Page 5: ...con el aparato ADVERTENCIA Para reducir el riesgo de incendio o toques eléctricos no use este ventilador con ningún dispositivo de estado sólido para controlar la velocidad del ventilador Modelo CP70 Enfriamiento Por Evaporación El enfriamiento por evaporación es una manera económica de enfriarse El aire se enfría mientras se traza a través de medio evaporativo mojado El movimiento de este aire en...

Page 6: ...n Funcionamiento Del Enfriador Bomba Para funcionar esta unidad como enfriador evaporativo necesita llenar la unidad con agua y presionar el bo tón Pump para arrancar la bomba El indicador de gotas de agua en la pantalla en la sección de la bomba parpadeará cuando la bomba está prendido Para funcionar la unidad como ventilador solamente presione Pump para apagar la bomba Nota La bomba no funcionar...

Page 7: ...en línea a www championcooler com eac onlineregistration eac htm Conservación ADVERTENCIA Siempre desconecte el enfriador antes de procurar cualquier tipo de servicio Drenar La Unidad Para drenar la unidad quite la armazón del medio evaporativo y quite el tapón de goma del desagüe situado en la parte inferior de la unidad Necesita drenar la unidad periódicamente para mantener el agua dulce Re come...

Page 8: ...onectó Piezas De Repuesto n Descripción CP70 1 Medio Evaporativo 110132 3 2 Montaje De Armazón Del Medio Evaporativo 110874 1 3 Canal De Agua 110874 3 4 Boquilla De Distribuidor De Agua 110874 4 5 Equipo De 4 Sujetadores 110871 6 Bomba 110439 1 7 Tapón De Goma 110698 8 Flotador y Indicador De Agua 110873 9 Rueda Giratoria Sin Frena 110822 6 10 Rueda Giratoria Con Frena 110822 7 11 Pedestal 110874 ...

Reviews: