background image

Undercounter High Temperature  

Dishwashing Machine  

with Built-in Booster Heater

UH-170B

UH-170B 

U

nderco

U

nter

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com

Dimensions shown in inches and [milimeters] 

Warning: 

Plumbing and electrical connections should be made by qualified personnel 

who will observe all the applicable plumbing, sanitary and safety  

codes and the National Electrical Code.

Note: 

Electrical supply 

service must be a 3-wire 

ground for connection 

shown.

Field convertible to accept 3 phase power

Volume crated:

 

 15 cu. ft.  

Shipping weight crated:

 

 215 lbs. 

CHAMPION 

UH170B 

2" [51]

1

2

3

40-1/2"

[1029]

14-3/4"

[375]

Clearance

33-3/4"

[857]

24" [610] 

15-3/4" [400]

4" [102]

25" [635]

2

3

CHAMPION 

UH170B 

2" [51]

1

2

3

40-1/2"

[1029]

14-3/4"

[375]

Clearance

33-3/4"

[857]

24" [610] 

15-3/4" [400]

4" [102]

25" [635]

2

3

CHAMPION 

UH170B 

2" [51]

1

2

3

40-1/2"

[1029]

14-3/4"

[375]

Clearance

33-3/4"

[857]

24" [610] 

15-3/4" [400]

4" [102]

25" [635]

2

3

SPecIFIcatIonS

Capacities

 

Cycle time (seconds) 

90

 

Racks per hr. (NSF) 

30

Motor horsepower

 

Wash 

1

Water consumption

 

U.S. Gal. per hr. (Max. use)  

28.2

 

U.S. Gal. per rack  

.9

Temperatures °F 

 

Wash 

150 

 

Rinse 

180 

Heating

 

Tank heat, electric, kW 

2.0

 

Electric booster  

(kW) required for 40°F rise) 

6

 

Electric booster 

 

(kW) required for 70°F rise) 

9

Time Cycle in Seconds

 

Wash 

70

 

Rinse 

15

 

Total cycle 

90

Standard 20” x 20” Rack Complement

 

Dish 

1

 

Open 

1

  UH-170 without booster 

  750 watt tank heat

 

Elec.                    Rated 

 

 

Specs.                    Amps 

  115/60/1                  12

 

115V

115V

208V

L1

L2

N

G

Utilities

1

Electrical

208-240/60/1; 3 wire plus ground, (See Box). 

208-240/60/3; 4 wire plus ground, (See Box).

2

Hot Water

1/2” supply; 140°F Min. hot water connection for 40°F rise booster; 110°F Min. 

hot water connection for 70°F rise booster. Incoming supply pressure must 

maintain a Flow pressure 20-22 PSI (Pressure reducing valve, PRV, supplied by 

customer or may be purchased unmounted from Champion).  

Machine equipped with 3/4” hose connector.

3

 Pumped Drain

5/8” I.D. flexible reinforced hose, 6 ft. long.   

Max. drain flow 15 US gpm. 

Max. drain height 3 ft. 

UH-170B with 40°F/22°C Rise Booster

Elec. Specs.

Rated 

Amps

Minimum 

Supply Ckt. 

Conductor 

Ampacity

Maximum 

Overcurrent 

Protective 

Device

208/60/1

32

40

40

240/60/1

36

40

40

208/60/3

22

30

30

240/60/3

24

30

30

UH-170B with 70°F/39°C Rise Booster

Elec. Specs.

Rated 

Amps

Minimum 

Supply Ckt. 

Conductor 

Ampacity

Maximum 

Overcurrent 

Protective 

Device

208/60/1

45

60

60

240/60/1

50

60

60

208/60/3

29

35

35

240/60/3

33

40

40

Side View

Front View

Plan View