Part 2:
INSTALLATION
2.7 Electrical Connections (Single Phase) Cont.
2.7.2 Models UH-200, UH-100, UL-100 Only
WARNING:
The installation of electrical supplies and controls must conform to local codes or, in the
absence of local codes, the National Electrical Code and good trade practices.
WARNING:
When working on the dishwasher, disconnect the electrical service and place a red tag
at the disconnect switch to indicate work is being done on that circuit.
!! ATTENTION INSTALLER !!
Use flexible conduit or cable to connect incoming power to the dishwasher to allow the machine
to be pulled out 5 ft. [1524mm] for servicing. A service loop is recommended. Service enters at
the right rear corner of the machine. The main connection block is located on the right side of the
dishwasher. See Section 1.4, page 4.
1.
A qualified electrician
must compare the electrical power supply with the machine
electrical specifications stamped on the MACHINE ELECTRICAL CONNECTION
PLATE before connecting to the incoming service through a fused disconnect switch or
circuit breaker (supplied by others). The plate is located near the main terminal block.
2. Models UH-200, UH-100 and UL-100 utilize a 120VAC power supply.
Power cord and plug are supplied by others.
Voltage
Machine
Hz
FLA
Phase
120/60/1
12.5
15/15
Single Phase Power Requirements
Models UL-100 Only
Min. Wire
Ampacity/
Max. Fuse Size
Voltage
Machine
Hz
FLA
Phase
120/60/1
19.3
25/25
Single Phase Power Requirements