R-Series Electric
19
CQF3473 v.01
Operation & Service
April 17, 2018
Compressor Oil Specifications (continued)
LUBRICANT LEVEL:
BREAK-IN PERIOD: 100 hours of operation or 3 months, whichever comes first.
1. Compressor must run for the break-in period using CHAMPLUB ISO 100 lubricant.
2. During the break-in period, a careful and regular check of the oil level should be made. Maintain
oil level at the full line.
3. After the break-in period, thoroughly drain existing oil from crankcase.
4. Add a full charge of CHAMPLUB ISO 100 lubricant.
CHANGING TO SYNTHETIC DIESTER BASED LUBRICANT
If changing to synthetic lubricant, the following steps must be completed.
1. Compressor must run for the break-in period using CHAMPLUB ISO 100 lubricant.
2. During the break-in period, a careful and regular check of the oil level should be made. Maintain
oil level at the full line.
3. After the break-in period, thoroughly drain existing oil from crankcase.
4. Add a full charge of CHAMPLUB SYNTHETIC lubricant.
5. Run compressor for 200 hours.
6. Stop compressor and thoroughly drain the synthetic lubricant.
7. Add a full charge of CHAMPLUB SYNTHETIC lubricant.
8. Compressor is now ready to run for extended period before next lubricant change. Maintain oil
level at the full line.
Maintain lubricant level
at center of sight glass