background image

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 

2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618

Dimensions shown in inches 

Volume crated:  

130 cu. ft.

Shipping weight crated:  

600 lbs.

Plumbing Notes:

 Because of the variation 

in house-supplied steam and water pressures, 

steam and water pressure regulating valves 

(PRVs) may be needed. (Water PRV is standard on 

machines with booster.) The PRVs can either be 

purchased from Champion or obtained locally.

Venting Notes: 

Fabricated duct size:  

3-7/8" x 15-7/8" (Outside dimensions) 

Warning: 

Plumbing and electrical connections 

should be made by qualified personnel who will 

observe all the applicable plumbing, sanitary, safety 

codes and the National Electrical Code.

Note: 

Water Hammer Arrestor (meeting ASSE-1010 

standard or equivalent) to be supplied (by others) in 

common water supply line at service connection.

Table a - Machine Connection

Table b - Machine & booster Connection

Utilities

 

1

  Electrical Connection

a

  Machine Only (see Table A) 

  Machine & Booster  (see Table B)

 

2

  Hot Water

3/4” NPT 180°F/82°C min. hot water 

connection. (Machine without booster.) 
3/4” NPT 140°F/60°C min. hot water 

connection. (40°F/34°C rise booster)
3/4” NPT 110°F/49°C min. hot water 

connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.

 

3

  Drain 

1-1/2” NPT machine connection.  

Maximum flow 15 gpm.

  4

  Steam 

a

  3/4” NPT machine connection.  

  Flow pressure 15-30 PSi. (Steam coil)

b

  3/4” NPT machine connection.  

  Flow pressure 15-30 PSi.  

  (Steam injector)

 

5

  Condensate 

(no back pressure)

1/2” NPT machine return to boiler

 

6

  Vents

a

  Load end: 200 CFM @ 1/4” S.P.

b

  Unload end: 400 CFM @ 1/4” S.P.  

  (With blower-dryer increase room    

  ventilation by 600 CFM.)

44” Single Tank  

High Temperature Rack  

Conveyor Dishwashing Machine with

Dual Stage Rinse

Model 44 dR

SPeCIFICaTIoNS

Capacity

 

Racks per hr. (NSF rated) 

208

Wash tank (US gal.) 

21

Conveyor speed (ft/min.) 

5.8

Motor Horsepower 

Drive  

1/6

Wash 2

Dual Rinse 

1/10

Heating

Wash Tank, electric (kW) 

15

DualRinse Tank electric (kW) 

Tank heat, steam (lbs/hr. 

required at 15 PSI flow pressure) 

75

Electric booster (built-in) 

(kW supplied for 40°F rise)   

12

Electric booster  

(kW supplied for 70°F rise) 

22

Steam booster (lbs./hr.  

required for 40°F rise) 

60

Steam booster (lbs./hr.  

required for 70°F rise) 

106

Water Consumption

US Gal. per hr. (max. use) 

112

US Gal. per rack 

.54

Venting 

Load end (minimum CFM) 

200

Unload end (minimum CFM) 

400

Standard 20” x 20”  

rack complement

Peg   

2

Flat   

1

Machine Only

Elec. 

Specs.

Rated 

Amps

Minimum 

Supply Ckt. 

Conductor 

Ampacity

Maximum 

Overcurrent 

Protective 

Device

208/60/1

111

150

150

240/60/1 

98

125

125

208/60/3 

70

90

90

240/60/3 

62

80

80

480/60/3 

31

40

40

575/60/3 

24

35

35

 Machine and steam built-in booster

Elec. 

Specs.

Rated 

Amps

Minimum 

Supply Ckt. 

Conductor 

Ampacity

Maximum 

Overcurrent 

Protective 

Device

208/60/1

33

45

45

240/60/1 

30

40

40

208/60/3 

25

35

35

240/60/3 

22

30

30

480/60/3 

12

15

15

575/60/3 

9

15

15

 70°F/39°C Rise – 22 kW  

 Machine and Electric built-in booster  

Elec. 

Specs.

Rated 

Amps

Minimum 

Supply Ckt. 

Conductor 

Ampacity

Maximum 

Overcurrent 

Protective 

Device

208/60/1

217

300

45

240/60/1 

190

250

250

208/60/3 

131

175

175

240/60/3 

115

150

150

480/60/3 

58

80

80

575/60/3 

47

60

60

40°F/22°C Rise – 12 kW 

Machine and Electric built-in booster

Elec. 

Specs.

Rated 

Amps

Minimum 

Supply Ckt. 

Conductor 

Ampacity

Maximum 

Overcurrent 

Protective 

Device

208/60/1

169

225

225

240/60/1 

148

200

200

208/60/3 

104

150

150

240/60/3 

91

125

125

480/60/3 

46

60

60

575/60/3 

37

50

50

Summary of Contents for DualRinse 44 DR

Page 1: ...res ENERGY STAR Qualified Exclusive DualRinse Technology Dual pawl cradle drive system One piece cast stainless steel upper lower spray arm assemblies Internal removable scrap basket and two piece scrap screen Standard vertical opening accommodates 18 x 26 sheet pans Wide 26 leakproof doors internally fitted Anti jam conveyor drive system Energy Sentinel Idle pump shut off Convenient top mounted c...

Page 2: ...washing Easily removable spray arm assembly for ease of cleaning Stainless steel pump housing and impeller Larger tanks hold more water for better washing results INTEGRATED BOOSTER HEATER As well as the E Series performs we created a way to make it perform even better The electric booster heater may be optional but it is an exceptional value engineered within the E Series footprint to offer a var...

Page 3: ...or Open Height 58 1 2 Machine Height 4 4 5 44 8 8 5 5 7 12 Plumbing Clearance 20 Clear 34 Load Height 20 Clear 34 Load Height 3 60 89 Door Removal 82 Door Open Height 58 1 2 Machine Height 7 12 Plumbing Clearance Cowl 2 4A 6A 5 1A 3 6B 4B 25 28 1 2 36 14 1 2 6 8 12 1 2 16 2 8 13 3 4 9 1 4 2 14 1 2 10 4A 4B 5 9 9 10 10 17 1 2 17 1 2 2 1 4 1 3 4 1 1 2 Can be up to 10 5 8 21 8 1 10 HP 1 10 HP End Vie...

Page 4: ...82 Door Open Height 58 1 2 Machine Height 4 4 5 44 8 8 5 5 7 12 Plumbing Clearance 20 Clear 34 Load Height 20 Clear 34 Load Height 3 60 89 Door Removal 82 Door Open Height 58 1 2 Machine Height 7 12 Plumbing Clearance 2 4A 6A 5 1A 3 6B 4B 25 28 1 2 36 14 1 2 6 8 12 1 2 16 2 8 13 3 4 9 1 4 2 14 1 2 10 4A 4B 5 9 9 10 10 17 1 2 17 1 2 2 1 4 1 3 4 1 1 2 Can be up to 10 5 8 21 8 1 10 HP 1 10 HP end vie...

Page 5: ...e return to boiler 6 Vents A Load end 200 CFM 1 4 S P B Unload end 400 cfm 1 4 S P With blower dryer increase room ventilation by 600 cfm 44 Single Tank High Temperature Rack Conveyor Dishwashing Machine with Dual Stage Rinse Model 44 DR SPECIFICATIONS Capacity Racks per hr NSF rated 208 Wash tank US gal 21 Conveyor speed ft min 5 8 Motor Horsepower Drive 1 6 Wash2 Dual Rinse 1 10 Heating Wash Tan...

Page 6: ...t in only Electric 22 kW 70 F rise built in only Cantilever sideloader with or without hood for 90 load operation Extended pawl bar extended drive unit for use with load tabling 90 Motorized rack curve unload 180 Motorized rack curve unload Racks peg or flat racks specify type Roller conveyor table mobile or stationary Steam pressure regulating valve unmounted Table limit switch unmounted recommen...