Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Dimensions shown in inches
Volume crated:
130 cu. ft.
Shipping weight crated:
600 lbs.
Plumbing Notes:
Because of the variation
in house-supplied steam and water pressures,
steam and water pressure regulating valves
(PRVs) may be needed. (Water PRV is standard on
machines with booster.) The PRVs can either be
purchased from Champion or obtained locally.
Venting Notes:
Fabricated duct size:
3-7/8" x 15-7/8" (Outside dimensions)
Warning:
Plumbing and electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary, safety
codes and the National Electrical Code.
Note:
Water Hammer Arrestor (meeting ASSE-1010
standard or equivalent) to be supplied (by others) in
common water supply line at service connection.
Table a - Machine Connection
Table b - Machine & booster Connection
Utilities
1
Electrical Connection
a
Machine Only (see Table A)
Machine & Booster (see Table B)
2
Hot Water
3/4” NPT 180°F/82°C min. hot water
connection. (Machine without booster.)
3/4” NPT 140°F/60°C min. hot water
connection. (40°F/34°C rise booster)
3/4” NPT 110°F/49°C min. hot water
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
3
Drain
1-1/2” NPT machine connection.
Maximum flow 15 gpm.
4
Steam
a
3/4” NPT machine connection.
Flow pressure 15-30 PSi. (Steam coil)
b
3/4” NPT machine connection.
Flow pressure 15-30 PSi.
(Steam injector)
5
Condensate
(no back pressure)
1/2” NPT machine return to boiler
6
Vents
a
Load end: 200 CFM @ 1/4” S.P.
b
Unload end: 400 CFM @ 1/4” S.P.
(With blower-dryer increase room
ventilation by 600 CFM.)
44” Single Tank
High Temperature Rack
Conveyor Dishwashing Machine with
Dual Stage Rinse
Model 44 dR
SPeCIFICaTIoNS
Capacity
Racks per hr. (NSF rated)
208
Wash tank (US gal.)
21
Conveyor speed (ft/min.)
5.8
Motor Horsepower
Drive
1/6
Wash 2
Dual Rinse
1/10
Heating
Wash Tank, electric (kW)
15
DualRinse Tank electric (kW)
3
Tank heat, steam (lbs/hr.
required at 15 PSI flow pressure)
75
Electric booster (built-in)
(kW supplied for 40°F rise)
12
Electric booster
(kW supplied for 70°F rise)
22
Steam booster (lbs./hr.
required for 40°F rise)
60
Steam booster (lbs./hr.
required for 70°F rise)
106
Water Consumption
US Gal. per hr. (max. use)
112
US Gal. per rack
.54
Venting
Load end (minimum CFM)
200
Unload end (minimum CFM)
400
Standard 20” x 20”
rack complement
Peg
2
Flat
1
Machine Only
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/1
111
150
150
240/60/1
98
125
125
208/60/3
70
90
90
240/60/3
62
80
80
480/60/3
31
40
40
575/60/3
24
35
35
Machine and steam built-in booster
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/1
33
45
45
240/60/1
30
40
40
208/60/3
25
35
35
240/60/3
22
30
30
480/60/3
12
15
15
575/60/3
9
15
15
70°F/39°C Rise – 22 kW
Machine and Electric built-in booster
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/1
217
300
45
240/60/1
190
250
250
208/60/3
131
175
175
240/60/3
115
150
150
480/60/3
58
80
80
575/60/3
47
60
60
40°F/22°C Rise – 12 kW
Machine and Electric built-in booster
Elec.
Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/1
169
225
225
240/60/1
148
200
200
208/60/3
104
150
150
240/60/3
91
125
125
480/60/3
46
60
60
575/60/3
37
50
50