background image

Dimensions shown in inches and [millimeters]

Door-type  

Low Temperature  

Dishwashing Machine

D-LF

  

D-LF 

D

oor-type

SpeciFicationS

Capacities

 

Racks per hr. (NSF rated) 

55

 

Wash tank US gal.  

(imp. gal./liters) 

9 (7.5/34)

Wash motor horsepower 

1

Water consumption

 

Gal. per hr.  (max. use) 

US gal.  

(imp. gal./liters) 

66 (55/248)

 

Gal. per rack  

US gal.  

(imp. gal./liters) 

1.2 (0.96/4.4)

Temperatures °F/°C

 

Wash 

140/60

 

Rinse 

140/60

Heating

 

Tank heat, electric (kW) 

4.7

Time cycle in seconds

 

Wash 

45

 

Dwell 

1

 

Rinse 

14

 

Total cycle 

60

Inside Tracks

2-7/8" [73]

5-1/4" [133] Min.

FRONT

20-1/8"[511]

5-1/4" [133] Min.

corner configuration

1

13" [330]

3

2

19"

[483]

26"

[660]

2

3

1

[102] 4"

26" [660]

9-1/4"

[229]

19-1/4"

[489]

13-3/4" [343]

plan View

Straight-through 

configuration

typical table 

construction

24-1/4" [616]

7-1/4" [184]

2-1/8" [54]

1-1/4" [32] Roll

20-7/8" [530]

1-1/8" 

[29]

 60-1/2" [1537]

8-7/8" [225]

A

A

11" [279]

2

3

1

84" [2134]

Door

Removal

75" [1805]

Doors Up

57-1/2" [1461]

Machine 

Height

34" [864]

Load

Height

17" [432]

Clearance

17" [432]

Clearance

20-1/4" [511]

Inside Track

2-7/8" [73]

FRONT

5-1/4" [133] Min.

 

For Electric Heat

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

  Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

 115/60/1* 

48 

55 

55

 208/60/1 

35 

45 

45

 240/60/1 

37 

45 

45

 208/60/3 

20 

25 

25

 240/60/3 

21 

25 

25

 480/60/3 

15 

15

 575/60/3 

15 

15

Length between table connections:  

26"/660 mm

Volume crated:  

51 cu. ft./1.45 cu.m.

Shipping weight crated:  

325 lbs./148 kg

Warning: 

Plumbing and electrical connection should be made 

by qualified personnel who will observe all the applicable plumbing, 

sanitary and safety codes and the National Electrical Code.

Plumbing Note: 

Because of the variation in house-supplied 

water and steam pressure, pressure regulating valves 

(PRV’s) for incoming water and steam supply are needed. The 

PRV’s can be purchased from Champion or obtained locally.

Note: 

Water Hammer Arrestor (meeting ASSE-1010 

standard or equivalent) to be supplied (by others) in 

common water supply line at service connection.

Caution: 

Silver, aluminum and pewter are attacked 

by sodium hypochlorite (liquid bleach). Champion low 
temperature dishwashing machines are designed for 
liquid bleach solutions not exceeding 50 ppm.

* 3kW wash tank heater

 

For Steam Heat

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

  Elec. 

Rated 

Conductor 

Protective 

  Specs. 

Amps 

Ampacity 

Device

 115/60/1 

22 

30 

30

 208/60/1 

12 

15 

15

 240/60/1 

11 

15 

15

 208/60/3 

15 

15

 240/60/3 

15 

15

 480/60/3 

15 

15

 575/60/3 

15 

15

utilities

 

Electrical: 

(See Box)

 

2

   Hot water:

  

3/4" NPT 140°F/60°C hot water connection.  
Flow pressure 20-22 psi. (138-151 kPa).

 

3

   Drain: 

2" O.D. connection. Max. flow 15 

US gpm (12 imp. gpm/54 lpm.) 
3/4" NPT machine return to boiler

a. 

Steam Injector Condensate

B. 

Steam Coil Condensate

Side View

Front View

Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.

Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 

2674 N. Service Road • Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618 