![Champion D-H1T Technical Manual Download Page 13](http://html.mh-extra.com/html/champion/d-h1t/d-h1t_technical-manual_2588489013.webp)
INSTALLATION
(Cont.)
Plumbing Connections
NOTE:
Plumbing connections must comply with all
applicable sanitary and plumbing codes.
Water Connections
1. All D-HB/H1T series dishwashers require a
single, hot water supply.
The hot water connection to all D-HB/H1T
series dishwashers is 3/4" NPT.
The connection is made from
underneath the dishwasher.
The following minimum water
temperatures are recommended:
D-HBT with built-in 40˚ rise electric
booster (Minimum 140˚F/60˚C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)
D-HBT with built-in 70˚ rise electric
booster (Minimum 110˚F/43˚C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)
D-H1T without built-in booster
(Minimum 180˚F/70˚C)
(Min./Max. flow pressure
20-22 PSI/138-151.8 kPa)
Refer to Figs. 5 and 6
Figure 6
Hot Water Connection
3/4" NPT
(D-H1T Only)
Figure 5
Hot Water Connection
3/4" NPT
(D-HBT Only)
7
INSTALLATION
8-7/8"
[225 mm]
FLOOR
FLOOR
8-7/8"
[225 mm]