Controls and Features
6
Rev 41152-20100413 E
Power Panel
(1) Engine Switch
– Press the switch to
the “Start” position to start the generator.
Flip to the “Off” position to turn off the
generator.
(2) Circuit Breakers
– Protects the
generator against electrical overload.
(3) Voltmeter
– Displays the output
voltage of the generator.
(4) 120 V 30 A Twist-Lock
– Protected
by a 25 A circuit breaker. This receptacle
powers 120 Volt AC, 60 Hz, single phase
loads requiring up to 25 Amps or 3000 watts
of power.
(5) 120/240 V 30 A Twist-Lock
–
Protected by a 25 A double throw circuit
breaker on each 120 Volt leg of the
receptacle. This receptacle powers 240 Volt
AC, 60 Hz, single phase loads requiring up
to 25 A or 5500 Watts of power. If an L14-
30P plug is wired for only one 120 Volt leg
(3-wire connection) then this receptacle
powers 120 Volt AC, 60 Hz, single phase
loads requiring up to 25 A or 2750 Watts of
power.
(6) 120 V 20 A Duplex
– protected by a
20 A circuit breaker. Use this duplex to
operate 120 Volt AC, single phase, 60 Hz
loads requiring up to 20 A 0r 2400 Watts of
power.
(7) Circuit Breakers
– Protects the
generator against electrical overload.
(8) 12 V 8.3 A DC Outlet
(9) Ground Terminal
– Consult an
electrician for local grounding regulations.