Add Fuel: Propane (LPG)
DANGER
NEVER place the LPG (liquefied petroleum gas) connector hose
OR LPG cylinder tank in the path of the muffler exhaust gas
stream of the generator during engine operation.
Connecting an LPG cylinder
1. Make sure the fuel select dial is in the “ENGINE STOP”
position.
2. Remove the rubber protective plug from the female connector
of the LPG hose.
3. Pull and hold the outer collar of the female connector and
insert it over the male connector. Release outer collar. Pull on
the hose to make sure it’s connected to the generator.
4. Connect the other end of the LPG hose to the LPG cylinder
valve and hand tighten.
5. Open valve on LPG cylinder and check all connections for
leaks by wetting the fittings with a solution of soap and
water. Bubbles which appear or bubbles which grow indicate
that a leak exists. If a leak exists at a fitting then turn off
the valve on the cylinder and tighten the fitting. Turn the
valve back on and recheck the fitting with the soap and
water solution. If the leak continues or if the leak is not at a
fitting then do not use the generator and contact a qualified
technician.
NOTICE
–
The LPG hose included with this unit works with standard
20, 30, and 40 pound LPG tanks.
–
Verify the requalification date on the cylinder has not
expired.
–
Always position the cylinder so the connection between the
cylinder valve and generator inlet won’t cause sharp bends
or kinks in the LPG hose.
CAUTION
Do not allow children to tamper or play with the LPG cylinder
or hose connections.
CAUTION
Use approved LPG cylinders equipped with an OPD (overfilling
prevention device) valve. Always keep the cylinder in a vertical
position with the valve on top and installed at ground level
on a flat surface. Cylinders must not be installed near any
heat source and should not be exposed to sun, rain, and dust.
When transporting and storing, turn off the cylinder valve and
generator LPG valve, and disconnect the cylinder. Plug the
outlet, usually by a plastic protective cap, if one is available.
Keep cylinders away from heat and ventilated when in a
vehicle.
WARNING
If there is a strong smell of LPG: Close valve on the cylinder.
Check all connections for leaks by wetting the fittings with a
solution of soap and water. Bubbles which appear or bubbles
which grow indicate that a leak exists. Do not smoke or light a
cigarette, or check for leaks using a match, open flame source
or lighter. Contact a qualified technician to inspect and repair
an LPG system if a leak is found, before using the generator.
Add Fuel: Natural Gas (NG)
DANGER
NEVER place NG connector hose in the path of the generator’s
muffler exhaust gas stream while the generator is running.
Connecting the NG hose
1. Use pipe sealant, joint compound, or Teflon tape when
connecting the adapter fitting from the hose kit to the NG
supply line.
2. Connect the female flare end of the NG hose to the adapter
fitting. NO pipe sealant, joint compound, or Teflon tape is to
be used on this connection.
3. Remove the rubber protective plug from the female quick
connect end of the NG hose.
4. Pull and hold the outer collar of the female quick connect and
insert it over the male connector on the generator. Release
outer collar. Pull on the hose to make sure it is securely
connected to the generator.