background image

201033 - 6000W PORTAbLE GENERATOR

31

WARRANTY

WARRANTY*

CHAMPION POWER EQUIPMENT 
3 YEAR LIMITED WARRANTY

Warranty Qualifications

To register your product for warranty and FREE lifetime call center 
technical support please visit: 

https://www.championpowerequipment.com/register

To complete registration you will need to include a copy of the 
purchase receipt as proof of original purchase. Proof of purchase 
is required for warranty service. Please register within ten (10) 
days from date of purchase.

Repair/Replacement Warranty

CPE warrants to the original purchaser that the mechanical and 
electrical components will be free of defects in material and 
workmanship for a period of three years (parts and labor) from 
the original date of purchase and 270 days (parts and labor) for 
commercial and industrial use. Transportation charges on product 
submitted for repair or replacement under this warranty are the 
sole responsibility of the purchaser. This warranty only applies to 
the original purchaser and is not transferable.

Do Not Return The Unit To The Place Of 
Purchase

Contact CPE’s Technical Service and CPE will troubleshoot any 
issue via phone or e-mail. If the problem is not corrected by 
this method, CPE will, at its option, authorize evaluation, repair 
or replacement of the defective part or component at a CPE 
Service Center. CPE will provide you with a case number for 
warranty service. Please keep it for future reference. Repairs or 
replacements without prior authorization, or at an unauthorized 
repair facility, will not be covered by this warranty.

Warranty Exclusions

This warranty does not cover the following repairs and equipment:

Normal Wear

Products with mechanical and electrical components need 
periodic parts and service to perform well. This warranty does not 
cover repair when normal use has exhausted the life of a part or 
the equipment as a whole.

Installation, Use and Maintenance

This warranty will not apply to parts and/or labor if the product is 
deemed to have been misused, neglected, involved in an accident, 
abused, loaded beyond the product’s limits, modified, installed 
improperly or connected incorrectly to any electrical component.  
Normal maintenance is not covered by this warranty and is not 
required to be performed at a facility or by a person authorized by 
CPE.

Other Exclusions

This warranty excludes:

 

Cosmetic defects such as paint, decals, etc.

 

Wear items such as filter elements, o-rings, etc.

 

Accessory parts such as starting batteries, and storage 
covers.

 

Failures due to acts of God and other force majeure events 
beyond the manufacturer’s control.

 

Problems caused by parts that are not original Champion 
Power Equipment parts.

When applicable, this warranty does not apply to products used 
for prime power in place of a utility.

Limits of Implied Warranty and 
Consequential Damage

Champion Power Equipment disclaims any obligation to cover 
any loss of time, use of this product, freight, or any incidental 
or consequential claim by anyone from using this product. 
THIS WARRANTY AND THE ATTACHED U.S. EPA and/or CARB 
EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE) 
ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, 
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE. 
A unit provided as an exchange will be subject to the warranty 
of the original unit. The length of the warranty governing the 
exchanged unit will remain calculated by reference to the purchase 
date of the original unit.
This warranty gives you certain legal rights which may change 
from state to state or province to province. Your state or province 
may also have other rights you may be entitled to that are not 
listed within this warranty.

Contact Information

Address

Champion Power Equipment, Inc. 
12039 Smith Ave. 
Santa Fe Springs, CA 90670 USA 
www.championpowerequipment.com

Customer Service

 

Toll Free: 1-877-338-0999 
[email protected] 
Fax no.: 1-562-236-9429

Technical Service

 

Toll Free: 1-877-338-0999 
[email protected] 

 

EMERGENCY 24 HOUR SUPPORT: 1-562-204-1188

*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency 
(EPA) and/or California Air Resources Board (CARB). Whichever warranty applies for the longer period, either this 3 year limited warranty or the applicable Emission Control System Warranty, 
shall supersede the other.

Summary of Contents for 201033

Page 1: ...Failure to do so could result in serious injury This manual should remain with the product Specifications descriptions and illustrations in this manual are as accurate as known at the time of publicat...

Page 2: ...all carbon monoxide risks you ll be better prepared to protect your family from this colorless oderless threat CARBON MONOXIDE SAFETY THE BIG PICTURE KNOW THE SYMPTOMS Headache Nausea Shortness of br...

Page 3: ...GFCI 22 Stopping the Engine 23 Moving the Generator 23 Operation at High Altitude 24 Maintenance 24 Cleaning the Generator 24 Changing the Engine Oil 24 Cleaning and Adjusting the Spark Plug 25 Clean...

Page 4: ...ort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this docu...

Page 5: ...parts can entangle hands feet hair clothing and or accessories Traumatic amputation or severe laceration can result Keep hands and feet away from rotating parts Tie up long hair and remove jewelry DO...

Page 6: ...nce is felt and then pull rapidly to avoid kickback DO NOT start or stop the engine with electrical devices plugged in and turned on CAUTION Exceeding the generator s running capacity can damage the g...

Page 7: ...into the generator at the gas station Always use an approved container to transfer the fuel to the generator DO NOT overfill the gasoline tank Always keep gasoline away from sparks open flames pilot...

Page 8: ...ion Changes B Updated dieline This artwork belongs to Champion Power Equipment The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the...

Page 9: ...g an electrocution hazard A transfer switch must be used when connecting to a building Fire Explosion Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns...

Page 10: ...YMBOL MEANING On Stop or Off High CO Warning Move generator to an open outdoor area Move to fresh air and get medical help if sick dizzy or weak CO Shield System Fault Electrical issue end of life Her...

Page 11: ...volume 3 Turn the fuel valve to ON position 4 Press engine switch to the ON position 5 Move choke lever to CHOKE position 6 Pull the recoil cord 7 Move the choke lever to RUN position 8 Plug in desir...

Page 12: ...art the engine 5 Fuel Valve Used to turn fuel supply on and off to engine 6 Air Filter Protects the engine by filtering dust and debris from the intake air 7 Recoil Starter Used to manually start the...

Page 13: ...e and hertz 3 Circuit Breakers Push Reset Protects the generator against electrical overloads RECEPTACLES A Y 120 240V AC 30A Locking NEMA L14 30R May be used to supply electrical power for operation...

Page 14: ...in hertz Example 60 0 hertz Run Time R Run time of the generator for the current session Example 6 hours Total Run Time Total run time of the generator since first operation Example 16 hours Intelliga...

Page 15: ...2 fl oz 1100 ml Oil Funnel 1 Assembly Parts Wheels 8 in 20 3 cm Never Flat Wheel A 2 Wheel Hub Cap B 2 Roll Pin C 2 Large R clip D 2 Engine Vibration Mounts Support Leg with Vibration Mounts E 2 Flang...

Page 16: ...on the frame 5 Secure with the r clip D 6 Re install hub cap on wheel 7 Repeat to attach the second wheel D A C B Install the Support Leg 1 Attach the support leg E to the generator frame with flange...

Page 17: ...k in period Using synthetic oil does not decrease the recommended oil change interval Full synthetic 5W 30 oil will aid in starting in cold ambient 41 F 5 C temperatures Add Fuel DANGER Gasoline vapor...

Page 18: ...e and or create potential hazards If a fuel stabilizer is used confirm that it is formulated to work with ethanol gasoline blends Any damages or hazards caused by using ethanol blended gasoline higher...

Page 19: ...ica si est enfermo mareado o d bil Aller l air frais et obtenir de l aide m dicale si malade tourdi ou faible PROCESS Colors LPN 1607 L SF Rev B Size 276 4 x 82 3 mm Artwork Notes 2mm safe margin to b...

Page 20: ...wn into occupied or confined spaces Always carefully consider wind and air currents when positioning generator Always allow generators to properly cool before transport or for storage purposes Failure...

Page 21: ...l of the recoil cord After first pull move choke to RUN position for up to 3 pulls of the recoil cord Too much choke leads to spark plug fouling engine flooding due to lack of incoming air This will c...

Page 22: ...1 Add this number to the number calculated in step 2 Starting wattage is the surge of power needed to start some electric driven equipment Following the steps listed under Power Management will guaran...

Page 23: ...minutes to stabilize internal temperatures of the engine and generator 3 Press the engine switch to the OFF position 4 Turn the fuel valve to the OFF position Important Always ensure that the fuel va...

Page 24: ...originally supplied standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance...

Page 25: ...spark required for ignition 4 Make certain the spark plug gap is 0 028 0 031 in 0 7 0 8 mm SPARK PLUG GAP 5 Refer to the spark plug types in Specifications when replacing the plug 6 Firmly re install...

Page 26: ...ke and muffler FIRST 5 HOURS BREAK IN Change oil EVERY 50 HOURS OR ANNUALLY Clean air filter Change oil if operating under heavy load or in hot environments EVERY 100 HOURS OR ANNUALLY Change oil Clea...

Page 27: ...valve to the ON position 3 Use the drain bolt on the carburetor to empty any excess gasoline from the gasoline tank and carburetor into an appropriate container Use a funnel and appropriate hose if ne...

Page 28: ...ure Recommended Engine Oil Type 80 100 120 28 9 F C 17 8 6 7 4 4 15 6 26 7 37 8 48 9 10W 30 5W 30 Full Synthetic 10W 40 5W 30 NOTICE Temperature will affect engine oil and engine performance Change th...

Page 29: ...ing carbon monoxide if the red LED light blinks on the panel Move generator to an open outdoor area Point exhaust away from people and buildings Move to fresh air and get medical help if sick dizzy or...

Page 30: ...and tighten wiring connections GFCI tripped Reset GFCI receptacle breakers by first pushing the TEST button then the RESET button until green LED illuminates Contact the help line Other Contact the he...

Page 31: ...or connected incorrectly to any electrical component Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE Other Exclusi...

Page 32: ...condition exits CPE will repair your small off road engine SORE and equipment at no cost to you including diagnosis parts and labor MANUFACTURER S WARRANTY COVERAGE This Emissions Control System is w...

Page 33: ...shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replace...

Page 34: ...Mounting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other p...

Reviews: