100574 - 3500W DIGITAL HYBRID INVERTER GENERATOR
OPERATION
19
Starting the Engine: Propane (LPG)
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Turn the fuel selector switch to the horizontal “LPG” position
and connect LPG hose.
4. Fully open the LPG cylinder fuel knob.
5. Push the engine switch to the “ON” position.
6. Pull the choke to the half “CHOKE” position.
7. Pull the starter cord slowly 1-5 times to prime the engine with
LPG.
8. Pull the starter cord slowly until resistance is felt and then
pull rapidly.
9. Allow the engine to warm up several seconds before gradually
pushing the choke to the “RUN” position.
"
NOTICE
For LPG restarts with hot engine in hot ambient
temperature > 86°F (30°C),
move the choke to the half
“CHOKE” position and prime the engine with only 1-2 slow
pulls. Then follow normal starting procedure.
"
NOTICE
For LPG starting in cold ambient < 59°F (15°C),
move the
choke to the half “CHOKE” position and prime the engine with
3-5 slow pulls. Then follow normal starting procedure.
"
NOTICE
If the engine starts but does not run make certain that the
generator is on a flat, level surface. The engine is equipped
with a low oil sensor that will prevent the engine from running
when the oil level falls below a critical threshold.