10
C h a m p i o n P u m p C o m p a n y
, Inc • P.O. Box 528 • Ashland, OH 44805
Phone 419-281-4500 • toll free 800-659-4491 • fax 419-616-1100
Models - CPSE1524, 2024, 3024, 3094
& 3044
16. Pull wires through large opening
in motor housing (4) an connect wires
with cord (22) in Conduit box (33) per
schematic in Figure 5.
17. Refi ll with cooling oil and place o-ring
(35) and conduit box (33)onto motor
housing (4). Place cap screws (36) and
washers (37) through conduit box into
motor housing and tighten to 16 ft lbs.
Cable Assembly:
18. For ALL Models - Check power cord
(22) for cracks or damage and replace
if required. Insert one friction ring (24),
grommet (25), one friction ring (24), and
gland nut (23) into motor housing (4) or
conduit box & cable assembly (33) and
torque gland nut (23) to 15 ft lbs.
19. on models
CPSE1594, 2094 & 2044
,
refi ll with with cooling oil and replace
pipe plug (20).
Power Cable
Motor Lead Number
Green (Ground) Green
Black
1
White
2
Flag Terminal
Capacitor
Flag Terminal
Capacitor
Power Cable
Motor Lead Number
Green (Ground) Green
Black
1 & 7
Red
2 & 8
White
3 & 9
4, 5 & 6 Together
Power Cable
Motor Lead Number
Green (Ground) Green
Black
1
Red
2
White
3
4
&
7
Together
5
&
8
Together
6
&
9
Together
Figure 5 - 115/230 Volt AC, 1Ph
Models: CPSE1524, CPSE2024, CPSE3024
Figure 4
Figure 5 - 208/230 Volt AC, 3Ph
Models: CPSE1594, CPSE2094, CPSE3094
Figure 5 - 460 Volt AC, 3Ph
Models: CPSE1544, CPSE2044, CPSE3044
Pump Wiring Schematics