background image

102006 - AUTOMATIC TRANSFER SWITCH WITH aXis CONTROLLER™ MODULE

UNPACkING

8

UNPACkING

1.  Use care when unpacking to avoid damaging transfer switch 

components. 

2.  Allow the ATS to acclimate to room temperature for 

a minimum of 24 hours before unpacking to prevent 
condensation on the electrical apparatus.

3.  Use a wet/dry vacuum cleaner or a dry cloth to remove dirt 

and packing material that may have accumulated in the 
transfer switch or any of its components during storage.

4.  Do not use compressed air to clean the switch, cleaning with 

compressed air can cause debris to lodge in the components 
and damage the switch per the ATS manufacturers 
specifications.

5.  Retain the ATS manual with or near the ATS for future 

reference.

TOOLS REQUIRED

NOT INCLUDED

5/16 in. Hex Wrench

Mounting Hardware
Line Voltage Wire

1/4 in. Flat Screwdriver

Conduit
Fittings

Location and Mounting

Install the ATS as close as possible to utility meter socket. Wires 
will run between the ATS and main distribution panel, proper 
installation and conduit are required by code. Mount the ATS 
vertically to a rigid supporting structure. To prevent the ATS or 
enclosure box from distortion, level all mounting points; use 
washers behind the mounting holes (outside the enclosure, 
between enclosure and supporting structure), see following image. 
The recommended fasteners are 1/4” lag screws. Always follow 
local code.

 

16 in.

406.4 mm

 

 

24 in.

609.5 mm

 

Electrical Grommet(s)

Grommets can be used in any enclosure knockout for NEMA 1 
installations. Grommets can only be used in the bottom enclosure 
knockouts for NEMA 3R installations, when installed outside.

Summary of Contents for 102006

Page 1: ...his manual contains important safety precautions which should be read and understood before operating the product Failure to do so could result in serious injury This manual should remain with the pro...

Page 2: ...atic Transfer Switch with aXis ControllerTM Module 6 Panel Board Safety Information 7 Unpacking 8 Location and Mounting 8 Electrical Grommet s 8 Installation Wiring for ATS Utility Socket 9 Wiring the...

Page 3: ...e Please always exercise common sense and always err on the side of caution when operating the product to ensure no accident property damage or injury occurs We want you to continue to use and be sati...

Page 4: ...operating technique the manufacturer does not specifically recommend follow all codes to ensure safety for personnel Many accidents are caused by failing to follow simple and fundamental rules codes...

Page 5: ...ntial and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment 152 Alternate Power Source 2 This switch will not transfer...

Page 6: ...ls and features Save this manual for future reference Champion Automatic Transfer Switch with aXis ControllerTM Module 1 aXis Controller 2 Antenna 3 Generator L1 and L2 Terminals 4 Battery Charger Fus...

Page 7: ...5 Wire land 5 B B BLACK 6 Wire land 6 B R RED A 120VAC circuit must be installed for battery charging From ATS fuse block or distribution panel install L1 and N to Wire land 2 and 3 respectively Autom...

Page 8: ...or future reference TOOLS REQUIRED NOT INCLUDED 5 16 in Hex Wrench Mounting Hardware Line Voltage Wire 1 4 in Flat Screwdriver Conduit Fittings Location and Mounting Install the ATS as close as possib...

Page 9: ...a wire brush All power cables must enter the enclosure through the enclosure knockouts 1 Determine where the flexible liquid tight conduit will pass through the building from the inside to outside Whe...

Page 10: ...voltage controls route your low voltage wiring into the ATS using code appropriate conduit and fittings Connect the wiring to pin 1 and pin 2 of either AC1 or AC2 as shown in the diagram above Please...

Page 11: ...lled HSB Off ATS will control the start of the HSB using the AC2 Relay In this setting the AC2 can not be used to manage a load Pins 1 and 3 of the AC2 connector will be used for the HSB startup signa...

Page 12: ...here are three tabs located at the top of the page ATS GEN and LMM Each tab will display the status for the Transfer Switch Home Standby Generator or Load Management Module s respectively 4 When finis...

Page 13: ...ICATIONS aXis ControllerTM Module Automatic Transfer Switch Model Number 102006 Enclosure Style NEMA 3R outdoor Maximum Amps 200 Nominal Volts 120 240 Load Management Circuits 4 Weight 43 lbs 19 6 kg...

Page 14: ...he life of a part or the equipment as a whole Installation Use and Maintenance This warranty will not apply to parts and or labor if the product is deemed to have been misused neglected involved in an...

Reviews: