Connecting Electrical Loads

1.  Let the engine stabilize and warm up for a few 

minutes after starting

2.  Plug in and turn on the desired 120 Volt AC single 

phase, 60 Hz electrical loads.

 

– DO NOT connect 3-phase loads to the generator.

 

– DO NOT connect 50 Hz loads to the generator.

 

– DO NOT overload the generator.

Connecting a generator to your electric utility 
company’s power lines or to another power source 
may be against the law. In addition this action, 
if done incorrectly, could damage your generator 
and appliances and could cause serious injury or 
even death to you or a utility worker who may be 
working on nearby power lines. If you plan to run a 
portable electric generator during an outage, please 
notify your electric utility company immediately 
and remember to plug your appliances directly 
into the generator. Do not plug the generator into 
any electric outlet in your home. Doing so could 
create a connection to the utility company power 
lines. You are responsible for ensuring that your 
generator’s electricity does not feed back into the 
electric utility power lines.
If the generator will be connected to a building 
electrical system, consult your local utility company 
or a qualified electrician. Connections must isolate 
generator power from utility power and must comply 
with all applicable laws and codes.

NOTE

OPERATION

Stopping the Engine

1.  Turn off and unplug all electrical loads. Never start 

or stop the generator with electrical devices plugged 
in or turned on.

2.  Let the generator run at no-load for several minutes 

to stabilize internal temperatures of the engine and 
generator.

3.  Turn the fuel valve to the “OFF” position.
4.  Let the engine run until fuel starvation has stopped 

the engine. This usually takes a few minutes.

5.  Press the engine switch to the “OFF” position.

Important:

 Always ensure that the fuel valve and the 

engine switch are in the “OFF” position when the engine 
is not in use.

If the engine will not be used for a period of two (2) 
weeks or longer, please see the Storage section for 
proper engine and fuel storage.

NOTE

If the engine starts but does not run make certain 
that the generator is on a flat, level surface. The 
engine is equipped with a low oil sensor that will 
prevent the engine from running when the oil level 
falls below a critical threshold.

NOTE

Starting the Engine Cont’d.

Summary of Contents for 100331

Page 1: ...UCTIONS Important safety instructions are included in this manual MADE IN CHINA REV 100331 20170908 100331 MODEL NUMBER 4500 Starting Watts 3650 Running Watts PORTABLE GENERATOR Manual Start T h ree Y...

Page 2: ...California to cause cancer or birth defects and other reproductive harm WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer and birth defec...

Page 3: ...the Engine 12 Do Not Overload Generator 13 Capacity 13 Power Management 13 Operation at High Altitude 13 Maintenance and Storage 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arr...

Page 4: ...the accuracy and completeness of the information in this manual and we reserve the right to change alter and or improve the product and this document at any time without prior notice Since CPE CET hi...

Page 5: ...s situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result...

Page 6: ...king Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can result in f...

Page 7: ...sparks that can start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements WAR...

Page 8: ...MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell PELIGRO DANGER El uso de un generador en interiores PUEDE MATARLO EN MINUTOS El escape del generador contie...

Page 9: ...k 2 Choke Used to start the engine 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used t...

Page 10: ...aker 4 120 Volt AC 30 Amp Twist Lock Receptacle NEMA L5 30R May be used to supply electrical power for the operation of 120 Volt AC single phase 60 Hz electrical loads 5 120 Volt AC 30 Amp Receptacle...

Page 11: ...rts Oil 0 6 qt 0 6 L Oil Funnel 1 Power Panel Symbols RESET The below symbols are located on the generator power panel Familiarize yourself with these symbols for quick reference of the components and...

Page 12: ...il will aid in starting in cold ambient 5 C 41 F NOTE We consider the first 5 hours of run time to be the break in period for the unit During the break in period stay at or below 50 of the running wat...

Page 13: ...s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel 1 Use clean fre...

Page 14: ...ll become hot If adequate cooling and breathing space are not supplied or if the generator is blocked or contained temperatures can become extremely heated and may lead to fire Surge Protection Electr...

Page 15: ...ctric utility power lines If the generator will be connected to a building electrical system consult your local utility company or a qualified electrician Connections must isolate generator power from...

Page 16: ...rong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING Operation at High Altitude The density of air at high altitude is lower th...

Page 17: ...oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spark plug cable from t...

Page 18: ...sh 5 Replace the spark arrester if it is damaged 6 Position the spark arrester in the muffler and attach with the three screws Failure to clean the spark arrester will result in degraded engine perfor...

Page 19: ...disconnected from the generator Long Term Storage over 1 year For storage over 1 year the fuel tank and carburetor must be completely drained of gasoline 1 Be sure all appliances are disconnected from...

Page 20: ...must be drained and the carburetor must be thoroughly cleaned This process involves technically advanced tasks For assistance please call our Technical Support line at 1 877 338 0999 If the fuel tank...

Page 21: ...PR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm or 0 028 0 031 in Oil Use 10 30W automotive oil Oil capacity is up to 0 6 qt 0 6 L DO NOT OVERFILL Please reference the following char...

Page 22: ...NS Parts Diagram 1 23 24 25 26 27 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 2 3 4 5 6 7 8 9 10 11 14 15 10 16 12 17 18 44 47 48 19 20 22 21 33 13 56 57 58 59 60 61 62 64 65 66 67 68 69 70 71 72 73...

Page 23: ...06 Lock Washer 6 4 34 1 5789 0620 1 Flange Bolt M6 x 20 Black 4 35 24 070800 00 Reversal Valve 1 36 2 06 006 Clamp 7 x 1 1 37 24 070030 00 Hole Breather Tube 1 38 122 070014 02 Pipe Reversal Valve 67...

Page 24: ...30 32 35 37 38 12 40 41 42 43 44 46 47 21 22 23 24 31 34 36 39 53 52 45 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 93 94 95 92 91 90 97 78 79 80 82 83 84 85 86 87 88 76 59 12 7...

Page 25: ...r 1 51 1 6177 06 Flange Nut M6 3 52 21 110001 00 Shaft Governor Arm 1 53 22 123000 01 Ignition Coil Silicon Rubber 1 54 1 5789 0625 Flange Bolt M6 x 25 2 55 23 110005 01 Spring Throttle Return 1 56 23...

Page 26: ...G Y GREEN WHITE RED In W L BLACK YELLOW BLUE Br W G B W BROWN IGNITION COIL SPARKING PLUG ENGINE BLOCK B EXW FW MW1 L Y Y AVR Br 30A OIL LEVEL SW Y CONTROL BOX BLOCK Y G Y EARTH TERMINAL ENG SW R W W...

Page 27: ...proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Ch...

Page 28: ...quired to be performed at a facility or by a person authorized by CPE Other Exclusions This warranty excludes Cosmetic defects such as paint decals etc Wear items such as filter elements o rings etc A...

Page 29: ...l system is warranted for two years subject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be r...

Page 30: ...ement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according to Subsection d below Any such emissions related part repai...

Page 31: ...ets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of origin...

Reviews: