1.
5.
2.
6.
4.
3.
Start Up / Arrancar / Commencez
Set Up / Einrichten / Installation
Open shipping carton.
Turn off and disconnect all electrical loads from both inverter generators.
Plug one pair of power leads - connecting red to red and black to black , and ground wire
to inverter #1.
Plug the second pair of power leads connecting red to red and black to black , and ground wire
to inverter #2.
Start both inverter engines according to the Operator’s Manual. Observe the green output indicator light
on the parallel kit panel – when the light is on, you may connect devices.
The two generators may be stacked one on top of the other by aligning the handle of the lower generator
with the handle recess of the parallel kit. Align the lower pads of the top generator with the pocket pads
of the parallel kit.
The economy switch must be in the same position on both generators.
Open rear door panel and take out the power leads and ground wires.
Remove caps from the power leads.
430 mm x 285 mm
FOLD