100745 - 2000W DUAL FUEL INVERTER GENERATOR
OPERATION
20
!
WARNING
Do not operate a device while it is plugged in to the 12V DC
outlet.
Prolonged exposure to engine exhaust can cause serious injury
or death.
!
CAUTION
While charging a device do not place on the exhaust side of the
generator. Extreme heat caused by exhaust can damage the
device, and cause a potential fire hazard.
Battery Charging
1. Before connecting the battery charging cable (included) to a
battery that is installed in a vehicle, disconnect the vehicle
battery ground cable from the negative (–) battery terminal.
2. Plug the battery charging cable into the 12V DC receptacle of
the generator.
3. Connect the red (+) battery charger lead to the red (+) battery
terminal.
4. Connect the black (–) battery charger lead to the black (–)
battery terminal.
5. Start the generator.
Important:
The 12V DC outlet is ONLY to be used with the
supplied 12V DC battery charging cable. The 12V DC output is
unregulated and will damage other 12V DC products. When using
the 12V DC outlet, turn the Economy mode switch to the “OFF”
position. Be sure all electric devices including the lines and
plug connections are in good condition before connection to the
generator.
!
CAUTION
Do not start the vehicle while the battery charging cable is
connected and the generator is running. It will not give the
battery a boost of power. The vehicle or the generator may
be damaged. Charge only vented wet lead acid batteries.
Other types of batteries may burst, causing personal injury or
damage.
"
NOTICE
Be sure all electric devices including the lines and plug
connections are in good condition before connection to the
generator.
Parallel Operation
The Champion model 100745 is parallel ready and can be
operated in parallel with another Champion unit to increase
the total available electrical power. A Champion model 100468
parallel kit (optional equipment) is required for parallel operation.
For a list of compatible models or to order a parallel kit, please
call customer service at 1-877-338-0999 or visit www.
championpowerequipment.com.
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator’s
manual.
Stopping the Engine
Gasoline
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Turn the EZ Start dial counterclockwise to the “STOP”
position.
+
-
+
-
Important:
Always ensure that the EZ Start dial and fuel vent on
the fuel cap are in the “OFF” position when the generator is not in
use.
Propane
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Close the fuel valve on the propane cylinder.
4. Turn the EZ Start dial clockwise to the “STOP” position.
+
-
+
-