Cover grill.

  To help keep out cold air you can use the optional 

plastic grill cover.  This cover may be purchased from your local 

distributor.  To install the cover, line up the grill cover with the grill 

so that the tabs on the cover will slide over the center section of the 

grill.  Slide the grill cover onto the grill.  The tabs will snap into 

place.  To remove, just pull the grill cover straight forward away 

from the grill.

• 

Unplug unit from power supply during extended periods of 

non-use.

By following the operating, installation, and maintenance suggestions 

as outlined, you can get many years of efficient and satisfactory 

service from your cooler.  In the event additional information is 

desired, your dealer will be more than glad to assist you in every 

possible way.

Vertical Duct Conversion

This window unit can be reconfigured to a vertical tunnel con

-

figuration for installation into smaller width openings.  Follow the 

subsequent steps if this is desired.  

Note:  Tunnel mount strips used 

to convert tunnel are not shipped with this cooler.  If desired, 

call Customer Service at 1-800-643-8341 to have it shipped to 

you at no cost.

1.  Remove the 9 screws 

from the sides and bot-

tom of the tunnel.

2.  Remove the top 4 mid-

dle screws of the top 

pan while holding the 

tunnel in place (Fig 9).  

Be careful not to drop 

the tunnel, or damage 

to the electric cords 

could occur.  You may 

need to loosen other 

screws in the top pan 

to make it easier to remove the tunnel.

3.  Rotate the tunnel 90 degrees counter-clockwise (Fig 10).  Be care-

ful as you rotate the tunnel that you don’t damage or disconnect 

the cords which are still connected to the controls and the front 

panel. 

4.  Insert the flange of the tunnel 

between the front panel and the 

top pan.  Line up the two larger 

holes in the tunnel with the 

center two holes of the top pan.  

(Fig 11).

5.  Using the screws taken from the 

top pan, secure the tunnel to the 

unit.  Do not tighten the screws, 

leave them loose until the rest of 

the tunnel has been secured.

6.  Line up the three holes at the 

bottom of the tunnel with 

the holes in the front panel.  

Using the screws taken from 

the bottom of the tunnel pre-

viously, secure the tunnel to 

the front panel.

7.  Make sure all the screws re-

moved from the top pan are in 

place and tighten all screws.

8.  Skip this step for the RWC35, 

RN35W, WC37 & N37W 

models.  Remove the three 

screws from each side of the 

front panel as shown in figure 

12.

 

CAUTION

: Make sure that 

you do not remove the bottom 

most screw.  It holds the blower 

housing in place.

  

9.  To cover up the gap in the front 

panel, use the two strips of metal 

obtained from Customer Service.  

Line up the holes in the metal strips 

to the holes in the front panel and 

secure them with the screws previ-

ously removed in step 8.  (See Fig. 

12)  Install the metal strips so that 

there is no gap between the top pan 

and the metal strip.  If there is a gap, turn the metal strip around.

NOTE:  When mounting a cooler with this type of vertical tunnel 

configuration, the unit should be supported by a flat support or 

stand.  The installation method mentioned in the owner’s manual 

using chains and legs should not be used.  The filler panels in 

the installation kit may be used to seal off the window above the 

cooler duct.

Wiring Diagrams

Manual Control

Remote Control

Hi

Low

Gnd

Com.

Black

Red

Green

White

Plug

Switch

Blower Motor

Pump 

Motor

Hi

Low

Gnd

Com.

Black

Red

Green

White

Ground 

Wire

Blower Motor

Pump 

Motor

LockPlate

w/ Grommet

Control

Ground 

Screw

Fig. 9

Remove top 

screws last. Do 

Not Drop Tunnel

Fig. 10

Fig. 11

Line up to the two 

middle holes

Fig. 12

Do Not Remove 

Bottom Screw

Metal 

Strip

Summary of Contents for Excel N37W

Page 1: ...or a combination of both The air is always fresh not stale laden with smoke and odors as happens with refrigerated air conditioning Vea el Espa ol en el interior 110496 1 2 19 www championcooler com M...

Page 2: ...operating the fan The pump must be on while operating the fan for cooling You may also want the pump turned off at times when just a fan is desired FAN button Pressing this button will cycle the fan t...

Page 3: ...gged This is for your safety Spring Start Up Oil bearings The blower bearings and cooler motor in this unit should be oiled with a few drops of non detergent 20 30 weight oil once each year The motor...

Page 4: ...between the front panel and the top pan Line up the two larger holes in the tunnel with the center two holes of the top pan Fig 11 5 Using the screws taken from the top pan secure the tunnel to the un...

Page 5: ...ginal purchaser only Problem Possible Cause Remedy Failure to start or no air delivery Inadequate air delivery with cooler running Inadequate cooling 1 No electrical power to unit Fuse blown Circuit b...

Page 6: ...110429 Model No Modelo Weight lbs Peso libras Cabinet Dimensions in Dimensions De La Caja pulgadas Window Opening Req d in Abertura Requerida pulgadas Dry Seco Operating Lleno Height Altura Width Anch...

Page 7: ...er Flow Assembly Montaje De Desag e 3OA 1 3OA 1 3OA 1 3OA 1 36 House Leg Collar Assembly Montaje De Collar De La Pata 3HL 3 2 3HL 3 2 3HL 1 2 3HL 1 2 37 House Leg Pata 310811 2 310811 2 310811 2 31081...

Page 8: ...mba por unos cuantos minutos para mojar los filtros antes de poner en marcha el ventilador Los posiciones HIGH COOLy LOWCOOL Ajuste el interruptor a la posici n HIGH COOL o LOW COOL para poner en marc...

Page 9: ...a que los topes de hule descansen contra el costado de la pared Apriete el tornillo del collar G fig 2 Instalaci n Instalar Las Patas NOTA Si instale la unidad sin el uso del equipo de instalaci n omi...

Page 10: ...ar n sobre la secci n de centro de la rejilla Deslice la cubierta sobre la rejilla Los clips de la cubierta se encajar n a presi n hacia lugar Para quitar d un tir n con cuidado a la cubierta quit ndo...

Page 11: ...ete los tornillos D jenlos flojos hasta que el resto del conducto se ha asegura do 6 Alinee los tres agujeros en el fondo del conducto con los agujeros en el panel delante ro Con los tornillos quitado...

Page 12: ...cuito desac tivado Cable el ctrico da ado 2 Correa muy floja o apretada 3 Motor recalentado Correa muy apretada Cojinetes de la rueda est n secos 4 Motor parado 1 Insuficiente abertura para que salga...