Champion Essick Excel N37W Manual Download Page 1

Circle the model of your cooler and 

record the serial number below.

Read Carefully All Of This Manual 

Before Installing The Unit.

Encierre con un circulo el modelo de su 

enfriador y escribe el número de serie abajo.

Lea Con Cuidado Todo Este Manual Antes 

De Instalar La Unidad.

Serial #

Número De Serie

Read And Save These Instructions

Evaporative Cooling

Evaporative cooling is nature’s way of cooling. When air is moved 

over a wet surface, water is evaporated and heat is absorbed.  When 

stepping out of a swimming pool with the wind blowing, evaporative 

cooling makes you feel cool, even though the air may be warm.  

The human body itself is cooled primarily by the evaporation of 

perspiration.

This unit works on the same principle.  Air is drawn across wet 

filter pads where the air is cooled by evaporation and then circulated 

throughout the building.  It is this combination of cooled air and the 

movement of air over the skin which makes it feel cool.

Unlike refrigeration systems which recirculate the air, an evaporative 

cooler continually brings in fresh air while exhausting old air.  You 

are completely replacing the air every 2 to 4 minutes by opening 

windows or doors or a combination of both.  The air is always fresh, 

not stale, laden with smoke and odors as happens with refrigerated 

air conditioning.

Vea el Español en el interior

110496-1

2-19

www.championcooler.com

Manual Control Units

WC37 • N37W

WC44 • N44W

WC46 • N46W

WC50 • N50W

Remote Control Units

RWC35 • RN35W

RWC44

RWC46 • RN46W

RWC50 • RN50W

Safety Rules

1.  Read these instructions carefully.

2. Unit must be in the 

Off Position

 and 

Unplugged

 from power 

receptacle when installing or performing any maintenance.

3. This cooler will run on 120 volt A.C., 60 Hz (cycle) current 

only.

4.  Motor and pump are grounded and have an automatic thermal 

overload switch which will shut motor off when it overheats.  The 

motor will restart automatically when it cools down.

5.  Pump receptacle is for grounded evaporative cooler pump only.  

Do not plug anything else into receptacle.

6.  Do Not operate any fan with a damaged cord or plug.  Discard fan 

or return to an authorized service facility for examination and/or 

repair.

7.  Do Not run cord under carpeting.  Do Not cover cord with throw 

rugs, runners or similar coverings.  Do Not route cord under 

furniture or appliances.  Arrange cord away from traffic area and 

where it will not be tripped over.

WARNING

:

  To reduce the risk of fire or electric shock, do not 

use this fan with any “solid-state fan speed control device.”

C H A M P I O N • E S S I C K

Window Evaporative 

Cooler Manual

Summary of Contents for Excel N37W

Page 1: ...or a combination of both The air is always fresh not stale laden with smoke and odors as happens with refrigerated air conditioning Vea el Espa ol en el interior 110496 1 2 19 www championcooler com M...

Page 2: ...operating the fan The pump must be on while operating the fan for cooling You may also want the pump turned off at times when just a fan is desired FAN button Pressing this button will cycle the fan t...

Page 3: ...gged This is for your safety Spring Start Up Oil bearings The blower bearings and cooler motor in this unit should be oiled with a few drops of non detergent 20 30 weight oil once each year The motor...

Page 4: ...between the front panel and the top pan Line up the two larger holes in the tunnel with the center two holes of the top pan Fig 11 5 Using the screws taken from the top pan secure the tunnel to the un...

Page 5: ...ginal purchaser only Problem Possible Cause Remedy Failure to start or no air delivery Inadequate air delivery with cooler running Inadequate cooling 1 No electrical power to unit Fuse blown Circuit b...

Page 6: ...110429 Model No Modelo Weight lbs Peso libras Cabinet Dimensions in Dimensions De La Caja pulgadas Window Opening Req d in Abertura Requerida pulgadas Dry Seco Operating Lleno Height Altura Width Anch...

Page 7: ...er Flow Assembly Montaje De Desag e 3OA 1 3OA 1 3OA 1 3OA 1 36 House Leg Collar Assembly Montaje De Collar De La Pata 3HL 3 2 3HL 3 2 3HL 1 2 3HL 1 2 37 House Leg Pata 310811 2 310811 2 310811 2 31081...

Page 8: ...mba por unos cuantos minutos para mojar los filtros antes de poner en marcha el ventilador Los posiciones HIGH COOLy LOWCOOL Ajuste el interruptor a la posici n HIGH COOL o LOW COOL para poner en marc...

Page 9: ...a que los topes de hule descansen contra el costado de la pared Apriete el tornillo del collar G fig 2 Instalaci n Instalar Las Patas NOTA Si instale la unidad sin el uso del equipo de instalaci n omi...

Page 10: ...ar n sobre la secci n de centro de la rejilla Deslice la cubierta sobre la rejilla Los clips de la cubierta se encajar n a presi n hacia lugar Para quitar d un tir n con cuidado a la cubierta quit ndo...

Page 11: ...ete los tornillos D jenlos flojos hasta que el resto del conducto se ha asegura do 6 Alinee los tres agujeros en el fondo del conducto con los agujeros en el panel delante ro Con los tornillos quitado...

Page 12: ...cuito desac tivado Cable el ctrico da ado 2 Correa muy floja o apretada 3 Motor recalentado Correa muy apretada Cojinetes de la rueda est n secos 4 Motor parado 1 Insuficiente abertura para que salga...