Note:

 When first turned on wait about 1 

1

/

2

 minutes 

for the circuitry to calibrate.

* resets to Auto Mode at dawn.

OPERATION

MANUAL MODE

Mode:

On-Time

Works: Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10

Minutes

x

Manual

To Dawn*

x

... back on.

1 Second 

OFF 

then

...

Manual  mode  only  works  at 

night  because  daylight  returns 

the sensor to AUTO.
Flip the light switch off for one 

second then back on to toggle 

between AUTO and MANUAL 

MODE.
Manual mode works only with 

the ON-TIME switch in the 1, 

5, or 10 position.

5.  Increase or decrease the sensitivity as needed. 

Too much sensitivity may cause false triggering 

due to heat sources in the coverage area (see 

Troubleshooting section).

6.  Set the amount of ON-TIME you want the 

light to stay on after motion is detected (1, 5, 

or 10 minutes). The timer will reset as long 

as there is motion present. Once motion has 

stopped,  the  timer  will  time-out  after  the 

selected amount of time.

9.1 m 

(30 ft.)

1.8 m 

(6 ft.)

  

Maximum

 

Maximum Range 

Coverage Angle*

 

(Side View) 

(Top View)

MANUAL MODE

AUTO

TEST

ON-TIME Switch at 1, 5, 

or 10 minutes

MODE SWITCHING SUMMARY

Flip light switch 

off for one second 

then back on*

* If you get confused while switching modes, turn 

the power off for one minute, then back on. After 

the calibration time the control will be in the AUTO 

mode.

150°

Rotating Sensor Head to Change Coverage Area

15

150

°

Figure 8

Summary of Contents for Secure Home SH-9132AU

Page 1: ...ly REQUIREMENTS The light control requires 230 volts AC If you want to use Manual Mode the control must be wired through a switch It is illegal for persons other than a licensed electricianorpersonauthorizedbylegislation to work on fixed wiring or other electrical installations Before installation record the model num ber listed inside the fixture Attach receipt in case of possible warranty issues...

Page 2: ... mounted 1 8 meters 6 feet above the ground Do not use dimmer switches or timers with this fixture The sensor on this light fixture detects motion by the movement of heat across the coverage area However following are examples of objects that also produce heat and can cause the sensor to trigger Pools of Water Air Conditioners Dryer Vents Animals Heating Vents Automobile Traffic If you suspect tha...

Page 3: ...rdrilltodrillintothewalltoprovide a suitable mounting for the screws Note Also drill a 6 mm deep pilot hole for the earth screw Bracket mounting screws are not included Use 4 mm dia 8G x 30 mm screws Care should be taken to avoid drilling or screwing into concealed electrical wiring For solid brick walls screws and masonry plugs should be used 6 Attachmountingbrackettowallwithaminimum of two screw...

Page 4: ...nstall fixture tail assembly see Figure 6 Use the nut removed to secure the tail assembly Mounting Screw Terminal Block Insulator Decorative Nut Terminal Block From Fixture From AC Source WIRING Connect the fixture wires to the terminal block according to diagram Make sure all screws on terminalblockaretightenedsecurelyandterminal block insulator is folded over terminal block WARNING Turn power of...

Page 5: ...hrough the coverage area noting where youarewhenthelightsturnon InTESTmode light will stay on for 5 seconds after motion has stopped and then turn off 4 If the fixture is equipped with a rotatable sensor see Figure 7 move the sensor head left or right to change the coverage area see Figure 8 Note Grasp the sensor only as shown and turn the entire sensor Any other method may damage the sensor Do no...

Page 6: ...itymaycausefalsetriggering due to heat sources in the coverage area see Troubleshooting section 6 Set the amount of ON TIME you want the light to stay on after motion is detected 1 5 or 10 minutes The timer will reset as long as there is motion present Once motion has stopped the timer will time out after the selected amount of time 9 1 m 30 ft 1 8 m 6 ft Maximum Maximum Range Coverage Angle Side ...

Page 7: ...urn light switch on 2 Check bulb and replace if necessary 3 Replace fuse or turn circuit breaker on 4 Recheck after dark 5 Verify wiring is correct Light comes on in daylight 1 Light control may be installed in a relatively dark location 2 Light control is in TEST 1 The fixture is operating normally under these conditions 2 Set ON TIME switch to 1 5 or 10 minutes Light comes on for no apparent rea...

Page 8: ... or return the Unit to you Exclusions This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than an authorised installer to repair dismantle reinstall or move the Unit to anot...

Reviews: