IMPORTANT SAFETY AND INSTALLATION INFORMATION

Before installing coach light, read all instructions carefully and keep owner’s manual for future refer-

ence.

• WARNING: To prevent electric shock, please ensure that power is disconnected before installation.

• This fixture must be connected to a 230V-240V ~ 50Hz power source.

• The fixture must be properly grounded.

• This fixture is designed for outdoor installation and should be mounted to a wall.

• To achieve best results, this fixture should be mounted 1.8 meters (6 feet) above the ground.

• Do not use dimmer switches or timers with this fixture.
The sensor on this light fixture detects “motion” by the movement of heat across the coverage area. 

However, following are examples of objects that also produce heat and can cause the sensor to trigger:

• Pools of Water 

• Air Conditioners

• Dryer Vents 

• Animals

• Heating Vents 

• Automobile Traffic

If you suspect that a heat source of this type is triggering the sensor, reduce the sensitivity.
The sensor on this fixture is more sensitive to the movement of heat moving across the coverage area 

and less sensitive to the movement of heat directly towards it.

 

Least Sensitive 

 Most Sensitive

Sensor

Motion

Motion

Summary of Contents for Secure Home SH-9132AU

Page 1: ...ly REQUIREMENTS The light control requires 230 volts AC If you want to use Manual Mode the control must be wired through a switch It is illegal for persons other than a licensed electricianorpersonauthorizedbylegislation to work on fixed wiring or other electrical installations Before installation record the model num ber listed inside the fixture Attach receipt in case of possible warranty issues...

Page 2: ... mounted 1 8 meters 6 feet above the ground Do not use dimmer switches or timers with this fixture The sensor on this light fixture detects motion by the movement of heat across the coverage area However following are examples of objects that also produce heat and can cause the sensor to trigger Pools of Water Air Conditioners Dryer Vents Animals Heating Vents Automobile Traffic If you suspect tha...

Page 3: ...rdrilltodrillintothewalltoprovide a suitable mounting for the screws Note Also drill a 6 mm deep pilot hole for the earth screw Bracket mounting screws are not included Use 4 mm dia 8G x 30 mm screws Care should be taken to avoid drilling or screwing into concealed electrical wiring For solid brick walls screws and masonry plugs should be used 6 Attachmountingbrackettowallwithaminimum of two screw...

Page 4: ...nstall fixture tail assembly see Figure 6 Use the nut removed to secure the tail assembly Mounting Screw Terminal Block Insulator Decorative Nut Terminal Block From Fixture From AC Source WIRING Connect the fixture wires to the terminal block according to diagram Make sure all screws on terminalblockaretightenedsecurelyandterminal block insulator is folded over terminal block WARNING Turn power of...

Page 5: ...hrough the coverage area noting where youarewhenthelightsturnon InTESTmode light will stay on for 5 seconds after motion has stopped and then turn off 4 If the fixture is equipped with a rotatable sensor see Figure 7 move the sensor head left or right to change the coverage area see Figure 8 Note Grasp the sensor only as shown and turn the entire sensor Any other method may damage the sensor Do no...

Page 6: ...itymaycausefalsetriggering due to heat sources in the coverage area see Troubleshooting section 6 Set the amount of ON TIME you want the light to stay on after motion is detected 1 5 or 10 minutes The timer will reset as long as there is motion present Once motion has stopped the timer will time out after the selected amount of time 9 1 m 30 ft 1 8 m 6 ft Maximum Maximum Range Coverage Angle Side ...

Page 7: ...urn light switch on 2 Check bulb and replace if necessary 3 Replace fuse or turn circuit breaker on 4 Recheck after dark 5 Verify wiring is correct Light comes on in daylight 1 Light control may be installed in a relatively dark location 2 Light control is in TEST 1 The fixture is operating normally under these conditions 2 Set ON TIME switch to 1 5 or 10 minutes Light comes on for no apparent rea...

Page 8: ... or return the Unit to you Exclusions This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than an authorised installer to repair dismantle reinstall or move the Unit to anot...